Source:http://linkedlifedata.com/resource/pubmed/id/10077013
Switch to
Predicate | Object |
---|---|
rdf:type | |
lifeskim:mentions | |
pubmed:issue |
2
|
pubmed:dateCreated |
1999-5-4
|
pubmed:abstractText |
The present study reports on a new calibration of the magnetic resonance imaging (MRI) signal intensity of a fast gradient-echo sequence used for in vivo myocardial perfusion quantification in patients. The signal from a FAST sequence preceded by a arrhythmia-insensitive magnetization preparation was calibrated in vitro using tubes filled with various gadolinium (Gd) solutions. Single short-axis views of the heart were obtained in patients (n = 10) with normal cardiac function. Myocardial and blood signal intensity were converted to concentration of Gd according to the in vitro calibration curve and fitted by a one-compartment model. K1 [first-order transfer constant from the blood to the myocardium for the gadolinium-diethylenetriamine-pentaacetic acid (Gd-DTPA)] and Vd (distribution volume of Gd-DTPA in myocardium) obtained from the fit of the MRI-derived perfusion curves were 0.72+/-0.22 (mL/min/g) and 15.3+/-5.22%. These results were in agreement with previous observations on animals and demonstrated that a reliable measurement of myocardial perfusion can be obtained by MRI in patients with an in vitro calibration procedure.
|
pubmed:language |
eng
|
pubmed:journal | |
pubmed:citationSubset |
IM
|
pubmed:chemical | |
pubmed:status |
MEDLINE
|
pubmed:month |
Feb
|
pubmed:issn |
1053-1807
|
pubmed:author | |
pubmed:issnType |
Print
|
pubmed:volume |
9
|
pubmed:owner |
NLM
|
pubmed:authorsComplete |
Y
|
pubmed:pagination |
197-203
|
pubmed:dateRevised |
2004-11-17
|
pubmed:meshHeading |
pubmed-meshheading:10077013-Calibration,
pubmed-meshheading:10077013-Contrast Media,
pubmed-meshheading:10077013-Coronary Circulation,
pubmed-meshheading:10077013-Female,
pubmed-meshheading:10077013-Gadolinium DTPA,
pubmed-meshheading:10077013-Heart,
pubmed-meshheading:10077013-Humans,
pubmed-meshheading:10077013-Image Processing, Computer-Assisted,
pubmed-meshheading:10077013-Magnetic Resonance Imaging,
pubmed-meshheading:10077013-Male,
pubmed-meshheading:10077013-Middle Aged,
pubmed-meshheading:10077013-Models, Cardiovascular,
pubmed-meshheading:10077013-Phantoms, Imaging
|
pubmed:year |
1999
|
pubmed:articleTitle |
Quantification of myocardial perfusion with FAST sequence and Gd bolus in patients with normal cardiac function.
|
pubmed:affiliation |
Départment de Radiologie, Hôpital Universitaue de Geneve, Switzerland. jean-paul.vallee@hcuge.ch
|
pubmed:publicationType |
Journal Article
|