CERETEC (Injection, Powder, Lyophilized, For Solution)

Source:http://www4.wiwiss.fu-berlin.de/dailymed/resource/drugs/906

Statements in which the resource exists as a subject.
PredicateObject
rdf:type
rdfs:label
CERETEC (Injection, Powder, Lyophilized, For Solution)
dailymed-instance:dosage
Tc99m labeled leukocytes for adjunctive localization of intra-abdominal infection or inflammation. The normal adult (70 kg) dose is 0.259-0.925 GBq (7-25 mCi) as Tc99m labeled leukocytes by intravenous injection. Optimal planar imaging is between 2-4 hours.<br/>Cerebral Scintigraphy: The recommended dose range for i.v. administration, of reconstituted sodium pertechnetate Tc99m exametazime in the average adult (70 kg) is 370-740 MBq (10-20 mCi). Dynamic imaging may be performed between 0 to 10 minutes following injection. Static imaging may be performed from 15 minutes up to 6 hours after injection.
dailymed-instance:descripti...
The Ceretec kit is supplied as a pack of 5 vials for use in the preparation of a technetium Tc99m exametazime intravenous injection as a diagnostic radiopharmaceutical for use as an adjunct in the detection of altered regional cerebral perfusion and for the radiolabeling of autologous leukocytes. Each vial of Ceretec contains a pre-dispensed sterile, non-pyrogenic, lyophilized mixture of 0.5 mg exametazime [(RR,SS)-4.8-diaza-3,6,6,9-tetramethylundecane-2, 10-dione bisoxime], 7.6��g stannous chloride dihydrate (minimum stannous tin 0.6��g; maximum total stannous and stannic tin 4.0��g per vial) and 4.5 mg sodium chloride, sealed under nitrogen atmosphere with a rubber closure. The product contains no antimicrobial preservative. Prior to publication of the USAN, exametazime was formerly known as hexamethylpropylene amine oxime (HM-PAO). The name HM-PAO appears in many publications. The structural formula of exametazime is: When sterile pyrogen-free sodium pertechnetate Tc99m in isotonic saline is added to the vial of Ceretec, a Tc99m complex of exametazime is formed. Administration is by intravenous injection for diagnostic use.<br/>Physical Characteristics: Technetium Tc99m decays by isomeric transition with a physical half-life of 6.03 hours.Photons that are useful for imaging studies are listed in Table 1.<br/>External Radiation: The specific gamma ray constant for technetium Tc99m is 206 microCoulomb kg/37 MBq-h, (0.8 R/millicurie-h) at 1 cm. The first half-value thickness of lead (Pb) for technetium Tc99m is 0.2 mm. A range of values for the relative attenuation of the radiation emitted by this radionuclide that results from interposition of various thicknesses of Pb is shown in Table 2. For example, the use of a 2.7 mm thickness of Pb will decrease the external radiation exposure by a factor of 1,000. To correct for physical decay of this radionuclide, the fractions that remain at selected intervals relative to the time of calibration are shown in Table 3.
dailymed-instance:clinicalP...
General: When technetium Tc99m pertechnetate is added to exametazime in the presence of stannous reductant, a lipophilic technetium Tc99m complex is formed. This lipophilic complex is the active moiety. It converts at approximately 12%/hour to less lipophilic species. When the secondary complex is separated from the lipophilic species, it is unable to cross the blood-brain-barrier. The useful life of the reconstituted agent is limited to 30 minutes.<br/>Pharmacokinetics: Studies in normal volunteers have shown that the technetium Tc99m complex of the RR,SS(d,l) diastereoisomer of exametazime is rapidly cleared from the blood after intravenous injection. Uptake in the brain reaches a maximum of 3.5-7.0% of the injected dose within one minute of injection. Up to 15% of the activity is eliminated from the brain by 2 minutes post injection, after which little activity is lost for the following 24 hours except by physical decay of technetium Tc99m. The activity not associated with the brain is widely distributed throughout the body, particularly in muscle and soft tissue. About 30% of the injected dose is found in the gastrointestinal tract immediately after injection and about 50% of this is excreted through the intestinal tract over 48 hours. Also, about 40% of the injected dose is excreted through the kidneys and urine over the 48 hours after injection.<br/>Leukocyte: The lipophilic Tc99m exametazime complex is taken up by leukocytes, and selectively retained in neutrophils. Label elution rate is up to 10% in the first hour.<br/>Pharmacodynamics: Tc99m-labeled leukocyte: Based upon in vivo recovery and very low lung and liver uptake, the labeled leukocytes are still functional. Following reinjection of the Tc99m labeled leukocytes the circulating granulocyte activity as a percentage of labeled granulocyte activity at 40 minutes after injection gave a mean of 37% (range 10-47%). During the first hour following injection of Tc99m labeled leukocytes, activity is seen in the lungs, liver, spleen, blood pool, bone marrow and the bladder. The kidneys (parenchyma and/or renal pelvis) and gall bladder may also be visualized. Over the first 1-6 hours, the Tc99m is visualized in the bowel. At 24 hours post-injection substantial colonicactivity is seen. The normal areas visualized in earlier scans are still visible.
dailymed-instance:activeIng...
dailymed-instance:contraind...
None known.
dailymed-instance:supply
The kit comprises 5 individual vials of sterile, non-pyrogenic, freeze-dried mixture of exametazime, stannous chloride dihydrate and sodium chloride, 5 radiation labels, 5 sterile alcohol swabs, 5 radiochemical purity worksheets, 5 labeling efficiency worksheets, 1 leukocyte labeling schematic and 1 package insert. NDC 17156-022-05<br/>Storage: Store the kit at 15��-25��C (59��-77��F). Store the formulated drug for up to 30 minutes at 20��-25��C (68��-77��F) using appropriate radiation shielding. This reagent kit is approved for use by persons licensed by the Illinois Emergency Management Agency pursuant to 32 Ill. Code Adm. Section, Section 330.260(a) and 335.4010 or under equivalent licenses of the U.S. Nuclear Regulatory Commission, or an Agreement State.
dailymed-instance:activeMoi...
dailymed-instance:inactiveI...
dailymed-instance:precautio...
As with any injected product, acute hypersensitivity or allergic reactions are possible. Limited reports have been received of hypersensitivity reactions following administration of Tc99m labeled leukocytes prepared using Tc99m exametazime. However, the materials used in leukocyte cell separation may cause hypersensitivity reactions. It is essential that cells are washed free of sedimentation agents before they are reinjected into the patient. In case of side effects following administration of radiopharmaceuticals, users should ensure the availability of appropriate medical treatment at the time of administration of any radiopharmaceutical to the patient. A thorough knowledge of the normal distribution of intravenously administered technetium Tc99m exametazime injection is essential in order to interpret pathologic studies accurately. Caution should be exercised in making the final diagnosis. Results can be affected by the presence of tumor, infarction, peritonitis, non-gastrointestinal or bony sites of inflammatory cell collections. The contents of the Ceretec vial are not radioactive. After the sodium pertechnetate Tc99m is added, the product is radioactive and adequate shielding of the final preparation must be maintained. The contents of the Ceretec vial are intended only for use in preparation of technetium Tc99m exametazime injection and are NOT to be administered directly to the patient.<br/>General: The contents of the Ceretec vial are sterile and pyrogen free. The vial contains no bacteriostatic preservative. It is essential that the user follow the directions carefully and adhere to strict aseptic procedures during preparation of the radiopharmaceutical. Radiopharmaceuticals should be used only by or under the control of physicians who are qualified by training and experience in the safe use and handling of radionuclides and whose experience and training have been approved by the appropriate governmental agency authorized to license the use of radionuclides. To minimize radiation dose to the bladder, the patient should be encouraged to void when the examination is completed and as often thereafter as possible. Adequate hydration should be encouraged to permit frequent voiding.<br/>Carcinogenesis, Mutagenesis, Impairment of Fertility: Long term animal studies have not been performed to evaluate carcinogenic potential or whether exametazime affects fertility in males or females. When evaluated in the Ames test, exametazime increased the apparent rate of gene mutation in the TA100 strain of S. typhimurium. Exametazime did not cause chromosomal aberrations in vitro (Chinese Hamster Ovary cells) or in vivo (rat bone marrow).<br/>Pregnancy Category C: Animal reproduction studies have not been conducted with Tc99m exametazime. It is also not known whether Tc99m exametazime can cause fetal harm when administered to a pregnant woman or if it can affect reproductive capacity. Therefore, Tc99m exametazime should not be administered to a pregnant woman unless the potential benefit justifies the potential risk to the fetus.<br/>Nursing Mothers: Technetium Tc99m is excreted in human milk during lactation. It is not known whether exametazime is excreted in human milk. Therefore, formula feedings should be substituted for breast feeding for 60 hours.<br/>Pediatric Use: Safety and effectiveness in pediatric patients have not been established.<br/>Geriatric Use: Clinical studies of Ceretec���did not include sufficient numbers of subjects aged 65 and over to determine whether they respond differently from younger subjects. Other reported clinical experience has not identified differences in responses between the elderly and younger patients. In general, dose selection for an elderly patient should be cautious, usually starting at the low end of the dosing range, reflecting the greater frequency of decreased hepatic, renal or cardiac function, and of concomitant disease or other drug therapy. This drug is known to be substantially excreted by the kidney, and the risk of toxic reactions to this drug may be greater in patients with impaired renal function. Because elderly patients are more likely to have decreased renal function, care should be taken in dose selection, and it may be useful to monitor renal function.
dailymed-instance:genericMe...
exametazime
dailymed-instance:fullName
CERETEC (Injection, Powder, Lyophilized, For Solution)
dailymed-instance:adverseRe...
Rash with generalized erythema, facial edema and fever has been reported in less than 1% of patients. A transient increase in blood pressure was seen in 8% of patients.
dailymed-instance:indicatio...
Technetium Tc99m exametazime scintigraphy may be useful as an adjunct in the detection of altered regional cerebral perfusion in stroke. Tc99m exametazime is indicated for leukocyte labeled scintigraphy as an adjunct in the localization of intra-abdominal infection and inflammatory bowel disease.
dailymed-instance:represent...
dailymed-instance:routeOfAd...
dailymed-instance:name
CERETEC