Statements in which the resource exists.
SubjectPredicateObjectContext
pubmed-article:9417335rdf:typepubmed:Citationlld:pubmed
pubmed-article:9417335lifeskim:mentionsumls-concept:C0237868lld:lifeskim
pubmed-article:9417335lifeskim:mentionsumls-concept:C0014792lld:lifeskim
pubmed-article:9417335lifeskim:mentionsumls-concept:C0032105lld:lifeskim
pubmed-article:9417335lifeskim:mentionsumls-concept:C0023516lld:lifeskim
pubmed-article:9417335lifeskim:mentionsumls-concept:C0036221lld:lifeskim
pubmed-article:9417335lifeskim:mentionsumls-concept:C2828354lld:lifeskim
pubmed-article:9417335lifeskim:mentionsumls-concept:C0036679lld:lifeskim
pubmed-article:9417335lifeskim:mentionsumls-concept:C1839735lld:lifeskim
pubmed-article:9417335lifeskim:mentionsumls-concept:C1417081lld:lifeskim
pubmed-article:9417335lifeskim:mentionsumls-concept:C1822783lld:lifeskim
pubmed-article:9417335lifeskim:mentionsumls-concept:C1425386lld:lifeskim
pubmed-article:9417335lifeskim:mentionsumls-concept:C0205554lld:lifeskim
pubmed-article:9417335lifeskim:mentionsumls-concept:C1516698lld:lifeskim
pubmed-article:9417335lifeskim:mentionsumls-concept:C2003864lld:lifeskim
pubmed-article:9417335lifeskim:mentionsumls-concept:C0450129lld:lifeskim
pubmed-article:9417335lifeskim:mentionsumls-concept:C0442711lld:lifeskim
pubmed-article:9417335lifeskim:mentionsumls-concept:C0920434lld:lifeskim
pubmed-article:9417335lifeskim:mentionsumls-concept:C0680854lld:lifeskim
pubmed-article:9417335lifeskim:mentionsumls-concept:C0439224lld:lifeskim
pubmed-article:9417335lifeskim:mentionsumls-concept:C0333668lld:lifeskim
pubmed-article:9417335pubmed:dateCreated1997-12-30lld:pubmed
pubmed-article:9417335pubmed:abstractTextPreviously published studies on automated blood component donation with the MCS 3p cell separator proved fairly good quality of the collected red blood cells (RBC) and fresh frozen plasma (FFP), with the disadvantage of a low hematocrit of the filtered RBC and a high platelet contamination of the FFP (RBCP-F protocol.) The DRBCP-F protocol was designed to eliminate the above-mentioned disadvantages and to provide 1 unit of leuko-depleted (filtered) RBC, 2 units of FFP, and additionally 1 platelet concentrate (PC) from the buffy coat. Twenty automated blood component collections (2 cycles, Latham bowl at 5,500 rpm, 230 ml isotonic saline for volume balance, PAGGS-M as additive solution) were performed. The RBC were filtered in a closed system after storage at 4 degrees C for 24 h. Blood cell counts and biochemical parameters of the RBC were determined initially and after 49 days. PC were separated from buffy coat after a soft spin. The volume of the RBC amounted to 293 +/- 12 ml (mean +/- SD) with a hematocrit of 0.61 +/- 0.05 l/l. Residual leukocytes after filtration were found to be 0.04 x 10(6) +/- 0.06 per unit. After storage, the following data were obtained: hemolysis 0.38%, ATP 2.1 +/- 0.4 mumol/g Hb, 2,3-diphosphoglycerate (2,3-DPG) 1.4 +/- 0.3 mumol/g Hb, ph 6.3 +/- 0.1, potassium 6.4 mmol per unit, and LDH in the supernatant was 219 U/l. None of the RBC showed bacterial growth after 49 days. The volume of the collected FFP was 398 +/- 32 ml, with 3.4 +/- 3.5 x 10(3) residual platelets and 5 +/- 12 leukocytes per microliter. Platelet concentrates contained 90.2 +/- 32 x 10(9) platelets in 88 +/- 14 ml plasma. Automated blood donation with the DRBCP-F protocol provided RBC with very low residual leukocyte counts, adequate hematocrit and good metabolic status up to 49 days, and FFP with low platelet contamination. The platelet concentrates were even superior to those prepared from whole blood using the buffy coat method. The storable leuko-depleted RBC are suitable for transfusion of chronically transfused patients in whom primary HLA sensitization should be prevented.lld:pubmed
pubmed-article:9417335pubmed:languagegerlld:pubmed
pubmed-article:9417335pubmed:journalhttp://linkedlifedata.com/r...lld:pubmed
pubmed-article:9417335pubmed:citationSubsetIMlld:pubmed
pubmed-article:9417335pubmed:statusMEDLINElld:pubmed
pubmed-article:9417335pubmed:issn1023-2028lld:pubmed
pubmed-article:9417335pubmed:authorpubmed-author:KretschmerVVlld:pubmed
pubmed-article:9417335pubmed:authorpubmed-author:ZeilerTTlld:pubmed
pubmed-article:9417335pubmed:issnTypePrintlld:pubmed
pubmed-article:9417335pubmed:volume34lld:pubmed
pubmed-article:9417335pubmed:ownerNLMlld:pubmed
pubmed-article:9417335pubmed:authorsCompleteYlld:pubmed
pubmed-article:9417335pubmed:pagination118-22lld:pubmed
pubmed-article:9417335pubmed:dateRevised2006-11-15lld:pubmed
pubmed-article:9417335pubmed:meshHeadingpubmed-meshheading:9417335-...lld:pubmed
pubmed-article:9417335pubmed:meshHeadingpubmed-meshheading:9417335-...lld:pubmed
pubmed-article:9417335pubmed:meshHeadingpubmed-meshheading:9417335-...lld:pubmed
pubmed-article:9417335pubmed:meshHeadingpubmed-meshheading:9417335-...lld:pubmed
pubmed-article:9417335pubmed:meshHeadingpubmed-meshheading:9417335-...lld:pubmed
pubmed-article:9417335pubmed:meshHeadingpubmed-meshheading:9417335-...lld:pubmed
pubmed-article:9417335pubmed:meshHeadingpubmed-meshheading:9417335-...lld:pubmed
pubmed-article:9417335pubmed:meshHeadingpubmed-meshheading:9417335-...lld:pubmed
pubmed-article:9417335pubmed:meshHeadingpubmed-meshheading:9417335-...lld:pubmed
pubmed-article:9417335pubmed:meshHeadingpubmed-meshheading:9417335-...lld:pubmed
pubmed-article:9417335pubmed:meshHeadingpubmed-meshheading:9417335-...lld:pubmed
pubmed-article:9417335pubmed:meshHeadingpubmed-meshheading:9417335-...lld:pubmed
pubmed-article:9417335pubmed:meshHeadingpubmed-meshheading:9417335-...lld:pubmed
pubmed-article:9417335pubmed:year1997lld:pubmed
pubmed-article:9417335pubmed:articleTitle[A new separation protocol (DRBCP-F) for automated blood component donation with the MCS 3p cell separator for collection of leukocyte depleted erythrocyte concentrates and plasma].lld:pubmed
pubmed-article:9417335pubmed:affiliationAbteilung für Transfusionsmedizin und Gerinnungsphysiologie, Philipps-Universität, Marburg, Deutschland.lld:pubmed
pubmed-article:9417335pubmed:publicationTypeJournal Articlelld:pubmed
pubmed-article:9417335pubmed:publicationTypeComparative Studylld:pubmed
pubmed-article:9417335pubmed:publicationTypeEnglish Abstractlld:pubmed