Statements in which the resource exists.
SubjectPredicateObjectContext
pubmed-article:9312708rdf:typepubmed:Citationlld:pubmed
pubmed-article:9312708lifeskim:mentionsumls-concept:C0021102lld:lifeskim
pubmed-article:9312708lifeskim:mentionsumls-concept:C1527148lld:lifeskim
pubmed-article:9312708lifeskim:mentionsumls-concept:C0185125lld:lifeskim
pubmed-article:9312708pubmed:issue5lld:pubmed
pubmed-article:9312708pubmed:dateCreated1997-9-30lld:pubmed
pubmed-article:9312708pubmed:abstractTextThe application of biodegradable implants is combined with advantages and disadvantages. They offer a great deal of innovative ideas. Best evaluation has been done with pins for the fixation of low loaded osteochondral fractures. When using 2.7 mm Polypin primary mechanical stability of distal radius fractures is comparable with the fixation by 1.8 mm K-wires. A prospective and randomised study with two years follow up, including 183 radial head fractures, showed no significant difference in results and complications in metal and polyactide implants. For this localisation and other comparable indications the implant can be recommended. Despite the more extensive degradable device overall costs can be reduced with the polymer implant. Orientruded polyactide screws showed good clinical results, newetheless resorption was extremely late within 5 to 7 years.lld:pubmed
pubmed-article:9312708pubmed:languagegerlld:pubmed
pubmed-article:9312708pubmed:journalhttp://linkedlifedata.com/r...lld:pubmed
pubmed-article:9312708pubmed:citationSubsetIMlld:pubmed
pubmed-article:9312708pubmed:chemicalhttp://linkedlifedata.com/r...lld:pubmed
pubmed-article:9312708pubmed:chemicalhttp://linkedlifedata.com/r...lld:pubmed
pubmed-article:9312708pubmed:statusMEDLINElld:pubmed
pubmed-article:9312708pubmed:monthMaylld:pubmed
pubmed-article:9312708pubmed:issn0085-4530lld:pubmed
pubmed-article:9312708pubmed:authorpubmed-author:RehmK EKElld:pubmed
pubmed-article:9312708pubmed:authorpubmed-author:HellingH JHJlld:pubmed
pubmed-article:9312708pubmed:authorpubmed-author:GatzkaCClld:pubmed
pubmed-article:9312708pubmed:issnTypePrintlld:pubmed
pubmed-article:9312708pubmed:volume26lld:pubmed
pubmed-article:9312708pubmed:ownerNLMlld:pubmed
pubmed-article:9312708pubmed:authorsCompleteYlld:pubmed
pubmed-article:9312708pubmed:pagination489-97lld:pubmed
pubmed-article:9312708pubmed:dateRevised2006-11-15lld:pubmed
pubmed-article:9312708pubmed:meshHeadingpubmed-meshheading:9312708-...lld:pubmed
pubmed-article:9312708pubmed:meshHeadingpubmed-meshheading:9312708-...lld:pubmed
pubmed-article:9312708pubmed:meshHeadingpubmed-meshheading:9312708-...lld:pubmed
pubmed-article:9312708pubmed:meshHeadingpubmed-meshheading:9312708-...lld:pubmed
pubmed-article:9312708pubmed:meshHeadingpubmed-meshheading:9312708-...lld:pubmed
pubmed-article:9312708pubmed:meshHeadingpubmed-meshheading:9312708-...lld:pubmed
pubmed-article:9312708pubmed:meshHeadingpubmed-meshheading:9312708-...lld:pubmed
pubmed-article:9312708pubmed:meshHeadingpubmed-meshheading:9312708-...lld:pubmed
pubmed-article:9312708pubmed:meshHeadingpubmed-meshheading:9312708-...lld:pubmed
pubmed-article:9312708pubmed:meshHeadingpubmed-meshheading:9312708-...lld:pubmed
pubmed-article:9312708pubmed:meshHeadingpubmed-meshheading:9312708-...lld:pubmed
pubmed-article:9312708pubmed:meshHeadingpubmed-meshheading:9312708-...lld:pubmed
pubmed-article:9312708pubmed:meshHeadingpubmed-meshheading:9312708-...lld:pubmed
pubmed-article:9312708pubmed:meshHeadingpubmed-meshheading:9312708-...lld:pubmed
pubmed-article:9312708pubmed:meshHeadingpubmed-meshheading:9312708-...lld:pubmed
pubmed-article:9312708pubmed:meshHeadingpubmed-meshheading:9312708-...lld:pubmed
pubmed-article:9312708pubmed:meshHeadingpubmed-meshheading:9312708-...lld:pubmed
pubmed-article:9312708pubmed:meshHeadingpubmed-meshheading:9312708-...lld:pubmed
pubmed-article:9312708pubmed:meshHeadingpubmed-meshheading:9312708-...lld:pubmed
pubmed-article:9312708pubmed:meshHeadingpubmed-meshheading:9312708-...lld:pubmed
pubmed-article:9312708pubmed:meshHeadingpubmed-meshheading:9312708-...lld:pubmed
pubmed-article:9312708pubmed:meshHeadingpubmed-meshheading:9312708-...lld:pubmed
pubmed-article:9312708pubmed:year1997lld:pubmed
pubmed-article:9312708pubmed:articleTitle[New developments in the application of resorbable implants].lld:pubmed
pubmed-article:9312708pubmed:affiliationKlinik und Poliklinik für Unfall-, Hand- und Wiederherstellungschirurgie, Universität zu Köln.lld:pubmed
pubmed-article:9312708pubmed:publicationTypeJournal Articlelld:pubmed
pubmed-article:9312708pubmed:publicationTypeClinical Triallld:pubmed
pubmed-article:9312708pubmed:publicationTypeComparative Studylld:pubmed
pubmed-article:9312708pubmed:publicationTypeEnglish Abstractlld:pubmed
pubmed-article:9312708pubmed:publicationTypeRandomized Controlled Triallld:pubmed
pubmed-article:9312708pubmed:publicationTypeMulticenter Studylld:pubmed
http://linkedlifedata.com/r...pubmed:referesTopubmed-article:9312708lld:pubmed