Statements in which the resource exists.
SubjectPredicateObjectContext
pubmed-article:8332855rdf:typepubmed:Citationlld:pubmed
pubmed-article:8332855lifeskim:mentionsumls-concept:C0005767lld:lifeskim
pubmed-article:8332855lifeskim:mentionsumls-concept:C1801960lld:lifeskim
pubmed-article:8332855lifeskim:mentionsumls-concept:C0232338lld:lifeskim
pubmed-article:8332855lifeskim:mentionsumls-concept:C0030054lld:lifeskim
pubmed-article:8332855lifeskim:mentionsumls-concept:C1511790lld:lifeskim
pubmed-article:8332855lifeskim:mentionsumls-concept:C0449438lld:lifeskim
pubmed-article:8332855lifeskim:mentionsumls-concept:C0178587lld:lifeskim
pubmed-article:8332855lifeskim:mentionsumls-concept:C0391841lld:lifeskim
pubmed-article:8332855lifeskim:mentionsumls-concept:C1282913lld:lifeskim
pubmed-article:8332855lifeskim:mentionsumls-concept:C2827421lld:lifeskim
pubmed-article:8332855pubmed:dateCreated1993-8-19lld:pubmed
pubmed-article:8332855pubmed:abstractTextThree factors are the major determinants of tissue oxygenation: blood oxygen content, blood flow and vascular density. Blood oxygen content can be measured in vitro by haemoximetry or in vivo by oximetry. The blood flow and the vascular density may be estimated by a further development of pulse oximetry, based on the photo-electric method separating the signal into an AC and DC-part. A circular finger-probe was constructed to analyse the propagation of light through blood perfused tissue by the photo-electric method. The AC and DC-signals were compared at different positions around the finger. The detectors were placed at -45 degrees, 45 degrees, 90 degrees, 180 degrees and 215 degrees in relation to the light source. The preliminary results have shown that it is possible to record AC and DC-signals from the different angles. The size and configuration of the AC-signals are very similar but the levels of the DC-signals decrease with the distance between source and detector. It is our suggestion that blood flow can be estimated from the area of the AC-signal and the vascular density from the relationship between the DC-levels at different positions.lld:pubmed
pubmed-article:8332855pubmed:languageenglld:pubmed
pubmed-article:8332855pubmed:journalhttp://linkedlifedata.com/r...lld:pubmed
pubmed-article:8332855pubmed:citationSubsetIMlld:pubmed
pubmed-article:8332855pubmed:chemicalhttp://linkedlifedata.com/r...lld:pubmed
pubmed-article:8332855pubmed:statusMEDLINElld:pubmed
pubmed-article:8332855pubmed:issn0085-591Xlld:pubmed
pubmed-article:8332855pubmed:authorpubmed-author:NielsenS LSLlld:pubmed
pubmed-article:8332855pubmed:authorpubmed-author:HansenTTlld:pubmed
pubmed-article:8332855pubmed:authorpubmed-author:LarsenV HVHlld:pubmed
pubmed-article:8332855pubmed:issnTypePrintlld:pubmed
pubmed-article:8332855pubmed:volume214lld:pubmed
pubmed-article:8332855pubmed:ownerNLMlld:pubmed
pubmed-article:8332855pubmed:authorsCompleteYlld:pubmed
pubmed-article:8332855pubmed:pagination75-81lld:pubmed
pubmed-article:8332855pubmed:dateRevised2004-11-17lld:pubmed
pubmed-article:8332855pubmed:meshHeadingpubmed-meshheading:8332855-...lld:pubmed
pubmed-article:8332855pubmed:meshHeadingpubmed-meshheading:8332855-...lld:pubmed
pubmed-article:8332855pubmed:meshHeadingpubmed-meshheading:8332855-...lld:pubmed
pubmed-article:8332855pubmed:meshHeadingpubmed-meshheading:8332855-...lld:pubmed
pubmed-article:8332855pubmed:meshHeadingpubmed-meshheading:8332855-...lld:pubmed
pubmed-article:8332855pubmed:year1993lld:pubmed
pubmed-article:8332855pubmed:articleTitleOxygen status determined by the photo-electric method--a circular finger-probe constructed for detection of blood oxygen content, blood flow and vascular density.lld:pubmed
pubmed-article:8332855pubmed:affiliationDepartment of Anaesthesiology, University of Copenhagen, Herlev Hospital, Denmark.lld:pubmed
pubmed-article:8332855pubmed:publicationTypeJournal Articlelld:pubmed