pubmed-article:7353277pubmed:abstractTextClearance of 0-100 mg/L concentrations of galactose from the blood depends on nutrient hepatic blood flow. We can measure such concentrations, which was not previously possible, by a continuous-flow method involving the use of galactose oxidase and peroxidase, the latter being coupled to a fluorogenic substrate, p-hydroxyphenylacetic acid. Interfering substances in the peroxidase reaction are removed by zinc/alkali precipitation. Sensitivity is maximized by using saturating concentrations of the enzymes and substrate. In prepared plasma test samples with galactose concentrations of 10, 40, 70, and 100 mg/L, the within-run CV's ranged from 2.1 to 8.6%, and day-to-day CV's from 2.2 to 17.2%, the largest CV's being for the 10 mg/L concentration. Normal subjects are shown to clear galactose more efficiently than subjects with moderate cirrhosis.lld:pubmed
pubmed-article:7353277pubmed:languageenglld:pubmed
pubmed-article:7353277pubmed:journalhttp://linkedlifedata.com/r...lld:pubmed
pubmed-article:7353277pubmed:citationSubsetIMlld:pubmed
pubmed-article:7353277pubmed:chemicalhttp://linkedlifedata.com/r...lld:pubmed
pubmed-article:7353277pubmed:chemicalhttp://linkedlifedata.com/r...lld:pubmed
pubmed-article:7353277pubmed:statusMEDLINElld:pubmed
pubmed-article:7353277pubmed:monthFeblld:pubmed
pubmed-article:7353277pubmed:issn0009-9147lld:pubmed
pubmed-article:7353277pubmed:authorpubmed-author:HendersonJ...lld:pubmed
pubmed-article:7353277pubmed:authorpubmed-author:GEVERGGlld:pubmed
pubmed-article:7353277pubmed:issnTypePrintlld:pubmed
pubmed-article:7353277pubmed:volume26lld:pubmed
pubmed-article:7353277pubmed:ownerNLMlld:pubmed
pubmed-article:7353277pubmed:authorsCompleteYlld:pubmed
pubmed-article:7353277pubmed:pagination282-5lld:pubmed
pubmed-article:7353277pubmed:dateRevised2004-11-17lld:pubmed
pubmed-article:7353277pubmed:meshHeadingpubmed-meshheading:7353277-...lld:pubmed
pubmed-article:7353277pubmed:meshHeadingpubmed-meshheading:7353277-...lld:pubmed
pubmed-article:7353277pubmed:meshHeadingpubmed-meshheading:7353277-...lld:pubmed
pubmed-article:7353277pubmed:meshHeadingpubmed-meshheading:7353277-...lld:pubmed
pubmed-article:7353277pubmed:meshHeadingpubmed-meshheading:7353277-...lld:pubmed
pubmed-article:7353277pubmed:meshHeadingpubmed-meshheading:7353277-...lld:pubmed
pubmed-article:7353277pubmed:meshHeadingpubmed-meshheading:7353277-...lld:pubmed
pubmed-article:7353277pubmed:meshHeadingpubmed-meshheading:7353277-...lld:pubmed
pubmed-article:7353277pubmed:meshHeadingpubmed-meshheading:7353277-...lld:pubmed
pubmed-article:7353277pubmed:year1980lld:pubmed
pubmed-article:7353277pubmed:articleTitleContinuous-flow fluorometry of low galactose concentrations in blood or plasma.lld:pubmed
pubmed-article:7353277pubmed:publicationTypeJournal Articlelld:pubmed
http://linkedlifedata.com/r...pubmed:referesTopubmed-article:7353277lld:pubmed