Statements in which the resource exists.
SubjectPredicateObjectContext
pubmed-article:7211907rdf:typepubmed:Citationlld:pubmed
pubmed-article:7211907lifeskim:mentionsumls-concept:C0036690lld:lifeskim
pubmed-article:7211907lifeskim:mentionsumls-concept:C0439849lld:lifeskim
pubmed-article:7211907lifeskim:mentionsumls-concept:C1704353lld:lifeskim
pubmed-article:7211907lifeskim:mentionsumls-concept:C2349974lld:lifeskim
pubmed-article:7211907lifeskim:mentionsumls-concept:C1521828lld:lifeskim
pubmed-article:7211907lifeskim:mentionsumls-concept:C0445223lld:lifeskim
pubmed-article:7211907lifeskim:mentionsumls-concept:C0150460lld:lifeskim
pubmed-article:7211907lifeskim:mentionsumls-concept:C1552599lld:lifeskim
pubmed-article:7211907lifeskim:mentionsumls-concept:C0243130lld:lifeskim
pubmed-article:7211907lifeskim:mentionsumls-concept:C1704787lld:lifeskim
pubmed-article:7211907pubmed:issue3lld:pubmed
pubmed-article:7211907pubmed:dateCreated1981-5-13lld:pubmed
pubmed-article:7211907pubmed:abstractTextContamination of the fluid within intra-arterial infusions used for hemodynamic monitoring has produced epidemic bacteremias, but little data exist on endemic rates of contamination and related septicemia. We prospectively studied 102 intra-arterial infusions used in 56 high-risk patients who required prolonged monitoring. During the study, administration sets were changed every 48 hours, but transducer chamber-domes and continuous flow devices were used until the intra-arterial infusion was discontinued. Cultures were obtained from the transducer-transducer chamber-dome interface and of fluid in the transducer chamber-dome of the 102 intra-arterial infusions; 12 (11.8 percent) showed contamination of transducer chamber-dome fluid, in 8 cases (7.8 percent) associated with concordant bacteremia. In each bacteremia, transducer chamber-dome fluid contained 1 to greater than 10(5) (median, 10(4)) cfu/ml. Four bacteremias are considered definitely related and four, possibly related, to the intra-arterial infusion. In all 12 contaminated intra-arterial infusions and with all eight bacteremias, the transducer chamber-dome had been used for more than two days (P = 0.006). No concordant contamination of transducer-transducer chamber-dome interfaces was identified. (1) Intra-arterial infusions for pressure monitoring cause sporadic septicemias endemically. (2) With prolonged monitoring, transducer chamber-domes and continuous flow devices should be replaced at periodic intervals, ideally with the administration set, every 48 hours; since implementing this policy, only three contaminated intra-arterial infusions and no related septicemias have been detected in 53 intra-arterial infusions monitored over our months (P = 0.02).lld:pubmed
pubmed-article:7211907pubmed:languageenglld:pubmed
pubmed-article:7211907pubmed:journalhttp://linkedlifedata.com/r...lld:pubmed
pubmed-article:7211907pubmed:citationSubsetAIMlld:pubmed
pubmed-article:7211907pubmed:statusMEDLINElld:pubmed
pubmed-article:7211907pubmed:monthMarlld:pubmed
pubmed-article:7211907pubmed:issn0002-9343lld:pubmed
pubmed-article:7211907pubmed:authorpubmed-author:MakiD GDGlld:pubmed
pubmed-article:7211907pubmed:authorpubmed-author:HassemerC ACAlld:pubmed
pubmed-article:7211907pubmed:issnTypePrintlld:pubmed
pubmed-article:7211907pubmed:volume70lld:pubmed
pubmed-article:7211907pubmed:ownerNLMlld:pubmed
pubmed-article:7211907pubmed:authorsCompleteYlld:pubmed
pubmed-article:7211907pubmed:pagination733-8lld:pubmed
pubmed-article:7211907pubmed:dateRevised2007-11-15lld:pubmed
pubmed-article:7211907pubmed:meshHeadingpubmed-meshheading:7211907-...lld:pubmed
pubmed-article:7211907pubmed:meshHeadingpubmed-meshheading:7211907-...lld:pubmed
pubmed-article:7211907pubmed:meshHeadingpubmed-meshheading:7211907-...lld:pubmed
pubmed-article:7211907pubmed:meshHeadingpubmed-meshheading:7211907-...lld:pubmed
pubmed-article:7211907pubmed:meshHeadingpubmed-meshheading:7211907-...lld:pubmed
pubmed-article:7211907pubmed:meshHeadingpubmed-meshheading:7211907-...lld:pubmed
pubmed-article:7211907pubmed:meshHeadingpubmed-meshheading:7211907-...lld:pubmed
pubmed-article:7211907pubmed:meshHeadingpubmed-meshheading:7211907-...lld:pubmed
pubmed-article:7211907pubmed:meshHeadingpubmed-meshheading:7211907-...lld:pubmed
pubmed-article:7211907pubmed:meshHeadingpubmed-meshheading:7211907-...lld:pubmed
pubmed-article:7211907pubmed:year1981lld:pubmed
pubmed-article:7211907pubmed:articleTitleEndemic rate of fluid contamination and related septicemia in arterial pressure monitoring.lld:pubmed
pubmed-article:7211907pubmed:publicationTypeJournal Articlelld:pubmed
http://linkedlifedata.com/r...pubmed:referesTopubmed-article:7211907lld:pubmed