pubmed-article:7096254 | rdf:type | pubmed:Citation | lld:pubmed |
pubmed-article:7096254 | lifeskim:mentions | umls-concept:C0003050 | lld:lifeskim |
pubmed-article:7096254 | lifeskim:mentions | umls-concept:C0000854 | lld:lifeskim |
pubmed-article:7096254 | lifeskim:mentions | umls-concept:C0001128 | lld:lifeskim |
pubmed-article:7096254 | lifeskim:mentions | umls-concept:C0003819 | lld:lifeskim |
pubmed-article:7096254 | lifeskim:mentions | umls-concept:C0302933 | lld:lifeskim |
pubmed-article:7096254 | lifeskim:mentions | umls-concept:C0680730 | lld:lifeskim |
pubmed-article:7096254 | lifeskim:mentions | umls-concept:C0936225 | lld:lifeskim |
pubmed-article:7096254 | lifeskim:mentions | umls-concept:C0747055 | lld:lifeskim |
pubmed-article:7096254 | lifeskim:mentions | umls-concept:C1706059 | lld:lifeskim |
pubmed-article:7096254 | lifeskim:mentions | umls-concept:C1148554 | lld:lifeskim |
pubmed-article:7096254 | lifeskim:mentions | umls-concept:C1708110 | lld:lifeskim |
pubmed-article:7096254 | pubmed:issue | 3 | lld:pubmed |
pubmed-article:7096254 | pubmed:dateCreated | 1982-9-10 | lld:pubmed |
pubmed-article:7096254 | pubmed:abstractText | 4-Hydroxy-3-nitrobenzenearsonic acid (roxarsone) is administered in animal feed as a growth stimulant over a concentration range of 25-50 ppm. The drug is extracted from 5 g feed with 200 mL aqueous 1.0% ammonium carbonate solution and 5 min of mechanical shaking. Undissolved feed particles are allowed to settle and 1.0 mL aliquot of extract is diluted with 9.0 mL 15% methanol solution. This solution is subjected to sample atomization by a graphite furnace and arsenic detection by atomic absorption spectrophotometry (AAS). Roxarsone recovery from nonmedicated commercial feed fortified at 25 ppm was 103.6% with a relative standard deviation (RSD) of 4.0%. Recovery for 50 ppm fortification was 104.5% (RSD 4.3%). Roxarsone assay results by furnace AAS were compared with results by the current AOAC spectrophotometric method and the AOAC total arsenic method. Results by the 3 methods compare well. The procedure was also used to determine other organic arsenicals and inorganic arsenic in laboratory-fortified feed samples; these recoveries were essentially theoretical. | lld:pubmed |
pubmed-article:7096254 | pubmed:language | eng | lld:pubmed |
pubmed-article:7096254 | pubmed:journal | http://linkedlifedata.com/r... | lld:pubmed |
pubmed-article:7096254 | pubmed:citationSubset | IM | lld:pubmed |
pubmed-article:7096254 | pubmed:chemical | http://linkedlifedata.com/r... | lld:pubmed |
pubmed-article:7096254 | pubmed:chemical | http://linkedlifedata.com/r... | lld:pubmed |
pubmed-article:7096254 | pubmed:chemical | http://linkedlifedata.com/r... | lld:pubmed |
pubmed-article:7096254 | pubmed:chemical | http://linkedlifedata.com/r... | lld:pubmed |
pubmed-article:7096254 | pubmed:status | MEDLINE | lld:pubmed |
pubmed-article:7096254 | pubmed:month | May | lld:pubmed |
pubmed-article:7096254 | pubmed:issn | 0004-5756 | lld:pubmed |
pubmed-article:7096254 | pubmed:author | pubmed-author:McDonnellJ... | lld:pubmed |
pubmed-article:7096254 | pubmed:author | pubmed-author:FrahmL JLJ | lld:pubmed |
pubmed-article:7096254 | pubmed:author | pubmed-author:GeorgeG MGM | lld:pubmed |
pubmed-article:7096254 | pubmed:issnType | Print | lld:pubmed |
pubmed-article:7096254 | pubmed:volume | 65 | lld:pubmed |
pubmed-article:7096254 | pubmed:owner | NLM | lld:pubmed |
pubmed-article:7096254 | pubmed:authorsComplete | Y | lld:pubmed |
pubmed-article:7096254 | pubmed:pagination | 711-9 | lld:pubmed |
pubmed-article:7096254 | pubmed:dateRevised | 2003-11-14 | lld:pubmed |
pubmed-article:7096254 | pubmed:meshHeading | pubmed-meshheading:7096254-... | lld:pubmed |
pubmed-article:7096254 | pubmed:meshHeading | pubmed-meshheading:7096254-... | lld:pubmed |
pubmed-article:7096254 | pubmed:meshHeading | pubmed-meshheading:7096254-... | lld:pubmed |
pubmed-article:7096254 | pubmed:meshHeading | pubmed-meshheading:7096254-... | lld:pubmed |
pubmed-article:7096254 | pubmed:meshHeading | pubmed-meshheading:7096254-... | lld:pubmed |
pubmed-article:7096254 | pubmed:meshHeading | pubmed-meshheading:7096254-... | lld:pubmed |
pubmed-article:7096254 | pubmed:meshHeading | pubmed-meshheading:7096254-... | lld:pubmed |
pubmed-article:7096254 | pubmed:meshHeading | pubmed-meshheading:7096254-... | lld:pubmed |
pubmed-article:7096254 | pubmed:meshHeading | pubmed-meshheading:7096254-... | lld:pubmed |
pubmed-article:7096254 | pubmed:year | 1982 | lld:pubmed |
pubmed-article:7096254 | pubmed:articleTitle | Graphite furnace atomic absorption spectrophotometric determination of 4-hydroxy-3-nitrobenzenearsonic acid, other organic arsenicals, and inorganic arsenic in finished animal feed. | lld:pubmed |
pubmed-article:7096254 | pubmed:publicationType | Journal Article | lld:pubmed |