pubmed-article:2605356pubmed:abstractTextConformable and conventional indwelling urinary catheters, made of latex coated with Teflon and of the same nominal size, were encrusted in vitro. The extent of encrustation was quantified by dissolving the deposits, determining the concentrations of calcium and magnesium in the resulting solutions (by atomic adsorption spectroscopy), and calculating the surface densities of calcium and magnesium. Surface densities of both elements were significantly less on the conformable than on the conventional catheters. This result can be explained by the pulsed flow of urine through the conformable catheter tending to dislodge deposits adhering to its inner surface. A similar action is expected to occur in vivo.lld:pubmed
pubmed-article:2605356pubmed:languageenglld:pubmed
pubmed-article:2605356pubmed:journalhttp://linkedlifedata.com/r...lld:pubmed
pubmed-article:2605356pubmed:citationSubsetIMlld:pubmed
pubmed-article:2605356pubmed:chemicalhttp://linkedlifedata.com/r...lld:pubmed
pubmed-article:2605356pubmed:chemicalhttp://linkedlifedata.com/r...lld:pubmed
pubmed-article:2605356pubmed:statusMEDLINElld:pubmed
pubmed-article:2605356pubmed:issn0890-5533lld:pubmed
pubmed-article:2605356pubmed:authorpubmed-author:HukinsD WDWlld:pubmed
pubmed-article:2605356pubmed:authorpubmed-author:CoxA JAJlld:pubmed
pubmed-article:2605356pubmed:authorpubmed-author:SuttonT MTMlld:pubmed
pubmed-article:2605356pubmed:authorpubmed-author:MillingtonR...lld:pubmed
pubmed-article:2605356pubmed:issnTypePrintlld:pubmed
pubmed-article:2605356pubmed:volume17lld:pubmed
pubmed-article:2605356pubmed:ownerNLMlld:pubmed
pubmed-article:2605356pubmed:authorsCompleteYlld:pubmed
pubmed-article:2605356pubmed:pagination429-35lld:pubmed
pubmed-article:2605356pubmed:dateRevised2000-12-18lld:pubmed
pubmed-article:2605356pubmed:meshHeadingpubmed-meshheading:2605356-...lld:pubmed
pubmed-article:2605356pubmed:meshHeadingpubmed-meshheading:2605356-...lld:pubmed
pubmed-article:2605356pubmed:meshHeadingpubmed-meshheading:2605356-...lld:pubmed
pubmed-article:2605356pubmed:meshHeadingpubmed-meshheading:2605356-...lld:pubmed
pubmed-article:2605356pubmed:meshHeadingpubmed-meshheading:2605356-...lld:pubmed
pubmed-article:2605356pubmed:meshHeadingpubmed-meshheading:2605356-...lld:pubmed
pubmed-article:2605356pubmed:year1989lld:pubmed
pubmed-article:2605356pubmed:articleTitleResistance of conformable indwelling urinary catheters to encrustation.lld:pubmed
pubmed-article:2605356pubmed:affiliationDepartment of Medical Biophysics, University of Manchester, UK.lld:pubmed
pubmed-article:2605356pubmed:publicationTypeJournal Articlelld:pubmed