Statements in which the resource exists.
SubjectPredicateObjectContext
pubmed-article:21424212rdf:typepubmed:Citationlld:pubmed
pubmed-article:21424212lifeskim:mentionsumls-concept:C0279516lld:lifeskim
pubmed-article:21424212lifeskim:mentionsumls-concept:C0005971lld:lifeskim
pubmed-article:21424212lifeskim:mentionsumls-concept:C0030685lld:lifeskim
pubmed-article:21424212lifeskim:mentionsumls-concept:C1979963lld:lifeskim
pubmed-article:21424212lifeskim:mentionsumls-concept:C1521827lld:lifeskim
pubmed-article:21424212lifeskim:mentionsumls-concept:C0680255lld:lifeskim
pubmed-article:21424212lifeskim:mentionsumls-concept:C0391871lld:lifeskim
pubmed-article:21424212lifeskim:mentionsumls-concept:C1283071lld:lifeskim
pubmed-article:21424212lifeskim:mentionsumls-concept:C2003903lld:lifeskim
pubmed-article:21424212lifeskim:mentionsumls-concept:C1963578lld:lifeskim
pubmed-article:21424212lifeskim:mentionsumls-concept:C1697272lld:lifeskim
pubmed-article:21424212lifeskim:mentionsumls-concept:C1522408lld:lifeskim
pubmed-article:21424212lifeskim:mentionsumls-concept:C1704806lld:lifeskim
pubmed-article:21424212lifeskim:mentionsumls-concept:C0871161lld:lifeskim
pubmed-article:21424212lifeskim:mentionsumls-concept:C0076732lld:lifeskim
pubmed-article:21424212lifeskim:mentionsumls-concept:C0290219lld:lifeskim
pubmed-article:21424212pubmed:issue4lld:pubmed
pubmed-article:21424212pubmed:dateCreated2011-5-2lld:pubmed
pubmed-article:21424212pubmed:abstractTextThe aim of the study was to explore the feasibility of the Ca-P coating titanium alloy plate to be used as the vancomycin drug-delivery system by biomimetic coating technology. Through the X-ray diffraction study, the main components of the coatings were identified as octocalcium phosphate. The in vitro vancomycin release, bacteriostasis activity to Staphylococcus aureus (S. aureus), the scanning electron microscope (SEM) image and osteoblast adhesion and proliferation test of vancomycin-loaded Ca-P coating plate were evaluated. The bacteriostatic activity of the vancomycin-loaded Ca-P coating plate showed a continuous drug release and had an inhibitory effect on the growth of the S. aureus. In vitro osteoblast culture results showed that the Ca-P coating plate loaded with or without the vancomycin both obviously promoted the osteoblast attachment. It was suggested that the vancomycin-loaded Ca-P coating may be compounded in the surface of the internal fixators to reduce the incidence of the implant-associated infection.lld:pubmed
pubmed-article:21424212pubmed:languageenglld:pubmed
pubmed-article:21424212pubmed:journalhttp://linkedlifedata.com/r...lld:pubmed
pubmed-article:21424212pubmed:citationSubsetIMlld:pubmed
pubmed-article:21424212pubmed:chemicalhttp://linkedlifedata.com/r...lld:pubmed
pubmed-article:21424212pubmed:chemicalhttp://linkedlifedata.com/r...lld:pubmed
pubmed-article:21424212pubmed:chemicalhttp://linkedlifedata.com/r...lld:pubmed
pubmed-article:21424212pubmed:chemicalhttp://linkedlifedata.com/r...lld:pubmed
pubmed-article:21424212pubmed:chemicalhttp://linkedlifedata.com/r...lld:pubmed
pubmed-article:21424212pubmed:chemicalhttp://linkedlifedata.com/r...lld:pubmed
pubmed-article:21424212pubmed:chemicalhttp://linkedlifedata.com/r...lld:pubmed
pubmed-article:21424212pubmed:statusMEDLINElld:pubmed
pubmed-article:21424212pubmed:monthAprlld:pubmed
pubmed-article:21424212pubmed:issn1573-4838lld:pubmed
pubmed-article:21424212pubmed:authorpubmed-author:UrenCClld:pubmed
pubmed-article:21424212pubmed:authorpubmed-author:DAYP EPElld:pubmed
pubmed-article:21424212pubmed:authorpubmed-author:LiuGuo-dongGDlld:pubmed
pubmed-article:21424212pubmed:authorpubmed-author:ChenJi-yingJYlld:pubmed
pubmed-article:21424212pubmed:authorpubmed-author:ZhouYong-gang...lld:pubmed
pubmed-article:21424212pubmed:authorpubmed-author:XiaoSong-huaS...lld:pubmed
pubmed-article:21424212pubmed:authorpubmed-author:YuHong-junHJlld:pubmed
pubmed-article:21424212pubmed:authorpubmed-author:PanChang-jian...lld:pubmed
pubmed-article:21424212pubmed:issnTypeElectroniclld:pubmed
pubmed-article:21424212pubmed:volume22lld:pubmed
pubmed-article:21424212pubmed:ownerNLMlld:pubmed
pubmed-article:21424212pubmed:authorsCompleteYlld:pubmed
pubmed-article:21424212pubmed:pagination989-95lld:pubmed
pubmed-article:21424212pubmed:meshHeadingpubmed-meshheading:21424212...lld:pubmed
pubmed-article:21424212pubmed:meshHeadingpubmed-meshheading:21424212...lld:pubmed
pubmed-article:21424212pubmed:meshHeadingpubmed-meshheading:21424212...lld:pubmed
pubmed-article:21424212pubmed:meshHeadingpubmed-meshheading:21424212...lld:pubmed
pubmed-article:21424212pubmed:meshHeadingpubmed-meshheading:21424212...lld:pubmed
pubmed-article:21424212pubmed:meshHeadingpubmed-meshheading:21424212...lld:pubmed
pubmed-article:21424212pubmed:meshHeadingpubmed-meshheading:21424212...lld:pubmed
pubmed-article:21424212pubmed:meshHeadingpubmed-meshheading:21424212...lld:pubmed
pubmed-article:21424212pubmed:meshHeadingpubmed-meshheading:21424212...lld:pubmed
pubmed-article:21424212pubmed:meshHeadingpubmed-meshheading:21424212...lld:pubmed
pubmed-article:21424212pubmed:meshHeadingpubmed-meshheading:21424212...lld:pubmed
pubmed-article:21424212pubmed:meshHeadingpubmed-meshheading:21424212...lld:pubmed
pubmed-article:21424212pubmed:meshHeadingpubmed-meshheading:21424212...lld:pubmed
pubmed-article:21424212pubmed:meshHeadingpubmed-meshheading:21424212...lld:pubmed
pubmed-article:21424212pubmed:year2011lld:pubmed
pubmed-article:21424212pubmed:articleTitlePreparation, release profiles and antibacterial properties of vancomycin-loaded Ca-P coating titanium alloy plate.lld:pubmed
pubmed-article:21424212pubmed:affiliationDepartment of Orthopedics, General Hospital of Chinese People's Liberation Army, Beijing 100853, China feijundoctor@sohu.comlld:pubmed
pubmed-article:21424212pubmed:publicationTypeJournal Articlelld:pubmed
pubmed-article:21424212pubmed:publicationTypeIn Vitrolld:pubmed
pubmed-article:21424212pubmed:publicationTypeResearch Support, Non-U.S. Gov'tlld:pubmed