pubmed-article:15691203 | pubmed:abstractText | The filter belt press is commonly used to dewater activated sludge. However, little research has been done on this process and the prediction of its efficiency. Experimentation has been carried out in a filtration compression cell (FCC) and in a pilot scale filter belt press. It offers a way of determining filter belt press efficiency thanks to simple laboratory research. The pressure distribution around the pressing roller was measured inside the pilot scale filter belt press. It showed progressive increase (up to a certain maximum value: plateau), which was followed by a rapid decrease. The impact of the progressive increase of applied pressure onto the dry solid sludge content was observed in FCC. Similar dry solid contents were obtained from both the above laboratory devices when the application of the pressure is comparable (in time and increasing rate). | lld:pubmed |