Statements in which the resource exists.
SubjectPredicateObjectContext
pubmed-article:9769269rdf:typepubmed:Citationlld:pubmed
pubmed-article:9769269lifeskim:mentionsumls-concept:C0035203lld:lifeskim
pubmed-article:9769269lifeskim:mentionsumls-concept:C0042491lld:lifeskim
pubmed-article:9769269lifeskim:mentionsumls-concept:C0009050lld:lifeskim
pubmed-article:9769269lifeskim:mentionsumls-concept:C0456261lld:lifeskim
pubmed-article:9769269lifeskim:mentionsumls-concept:C0392756lld:lifeskim
pubmed-article:9769269pubmed:issue4lld:pubmed
pubmed-article:9769269pubmed:dateCreated1998-11-13lld:pubmed
pubmed-article:9769269pubmed:abstractTextThe aim of this study was to determine the relationship of pulmonary vascular resistance (PVR) hysteresis and lung volume, with special attention to the effects of ventilation around closing volume (CV). Isolated, blood-perfused canine left lower lung lobes (LLL) were incrementally inflated and deflated. Airway and pulmonary artery pressures (PAP) were recorded after each stepwise volume change. Constant blood flow was provided (600 ml/min) and the pulmonary vein pressure (PVP) was held constant at 5 cm H2O. PAP changes, therefore, were a direct index of PVR changes. Group 1 lobes underwent a full inflation from complete collapse to total lobe capacity (TLC) followed by a full deflation. Group 2 lobes underwent two deflation/inflation cycles, after an initial full inflation. These cycles, both beginning at TLC, had deflation end above and below CV, respectively. Significant PVR hysteresis was noted when the first inflation and deflation were compared. The maximum difference in PAP on deflation was 3.3 cm H2O or 11%. The mean decrease was 2.7 cm H2O for 18 lobes (p < 0.0001). The PAPs on all subsequent inflations or deflations that began above CV remained 9% lower than the initial inflation (n = 9, p < 0.0001), but were not different from each other. However, the final inflation which began from below CV resulted in a 30% return of PVR hysteresis (mean increase in PAP of 0.8 cm H2O, n = 7, p < 0.004). We conclude that there is hysteresis in the PVR response during ventilation, with decreased PVR during deflation relative to the initial inflation, that this hysteresis is absent when lung volume is maintained greater than CV, and that hysteresis returns when inflation occurs after deflation below CV.lld:pubmed
pubmed-article:9769269pubmed:languageenglld:pubmed
pubmed-article:9769269pubmed:journalhttp://linkedlifedata.com/r...lld:pubmed
pubmed-article:9769269pubmed:citationSubsetAIMlld:pubmed
pubmed-article:9769269pubmed:statusMEDLINElld:pubmed
pubmed-article:9769269pubmed:monthOctlld:pubmed
pubmed-article:9769269pubmed:issn1073-449Xlld:pubmed
pubmed-article:9769269pubmed:authorpubmed-author:EhrhartI CIClld:pubmed
pubmed-article:9769269pubmed:authorpubmed-author:FisherL ELElld:pubmed
pubmed-article:9769269pubmed:authorpubmed-author:McCloudL LLLlld:pubmed
pubmed-article:9769269pubmed:authorpubmed-author:CreamerK MKMlld:pubmed
pubmed-article:9769269pubmed:issnTypePrintlld:pubmed
pubmed-article:9769269pubmed:volume158lld:pubmed
pubmed-article:9769269pubmed:ownerNLMlld:pubmed
pubmed-article:9769269pubmed:authorsCompleteYlld:pubmed
pubmed-article:9769269pubmed:pagination1114-9lld:pubmed
pubmed-article:9769269pubmed:dateRevised2008-11-21lld:pubmed
pubmed-article:9769269pubmed:meshHeadingpubmed-meshheading:9769269-...lld:pubmed
pubmed-article:9769269pubmed:meshHeadingpubmed-meshheading:9769269-...lld:pubmed
pubmed-article:9769269pubmed:meshHeadingpubmed-meshheading:9769269-...lld:pubmed
pubmed-article:9769269pubmed:meshHeadingpubmed-meshheading:9769269-...lld:pubmed
pubmed-article:9769269pubmed:meshHeadingpubmed-meshheading:9769269-...lld:pubmed
pubmed-article:9769269pubmed:meshHeadingpubmed-meshheading:9769269-...lld:pubmed
pubmed-article:9769269pubmed:meshHeadingpubmed-meshheading:9769269-...lld:pubmed
pubmed-article:9769269pubmed:meshHeadingpubmed-meshheading:9769269-...lld:pubmed
pubmed-article:9769269pubmed:meshHeadingpubmed-meshheading:9769269-...lld:pubmed
pubmed-article:9769269pubmed:meshHeadingpubmed-meshheading:9769269-...lld:pubmed
pubmed-article:9769269pubmed:meshHeadingpubmed-meshheading:9769269-...lld:pubmed
pubmed-article:9769269pubmed:meshHeadingpubmed-meshheading:9769269-...lld:pubmed
pubmed-article:9769269pubmed:meshHeadingpubmed-meshheading:9769269-...lld:pubmed
pubmed-article:9769269pubmed:meshHeadingpubmed-meshheading:9769269-...lld:pubmed
pubmed-article:9769269pubmed:meshHeadingpubmed-meshheading:9769269-...lld:pubmed
pubmed-article:9769269pubmed:meshHeadingpubmed-meshheading:9769269-...lld:pubmed
pubmed-article:9769269pubmed:year1998lld:pubmed
pubmed-article:9769269pubmed:articleTitleVentilation above closing volume reduces pulmonary vascular resistance hysteresis.lld:pubmed
pubmed-article:9769269pubmed:affiliationDepartment of Pediatrics, Section of Pediatric Critical Care Medicine, and Department of Physiology, Vascular Biology Center, Medical College of Georgia, Augusta, Georgia, USA. KCREAMER@mail.mcg.edulld:pubmed
pubmed-article:9769269pubmed:publicationTypeJournal Articlelld:pubmed
pubmed-article:9769269pubmed:publicationTypeComparative Studylld:pubmed
pubmed-article:9769269pubmed:publicationTypeResearch Support, Non-U.S. Gov'tlld:pubmed
http://linkedlifedata.com/r...pubmed:referesTopubmed-article:9769269lld:pubmed