Statements in which the resource exists.
SubjectPredicateObjectContext
pubmed-article:9538556rdf:typepubmed:Citationlld:pubmed
pubmed-article:9538556lifeskim:mentionsumls-concept:C1623258lld:lifeskim
pubmed-article:9538556lifeskim:mentionsumls-concept:C1511790lld:lifeskim
pubmed-article:9538556lifeskim:mentionsumls-concept:C0678226lld:lifeskim
pubmed-article:9538556lifeskim:mentionsumls-concept:C0936012lld:lifeskim
pubmed-article:9538556lifeskim:mentionsumls-concept:C0392762lld:lifeskim
pubmed-article:9538556lifeskim:mentionsumls-concept:C0743559lld:lifeskim
pubmed-article:9538556lifeskim:mentionsumls-concept:C2346501lld:lifeskim
pubmed-article:9538556lifeskim:mentionsumls-concept:C1299997lld:lifeskim
pubmed-article:9538556lifeskim:mentionsumls-concept:C1711330lld:lifeskim
pubmed-article:9538556pubmed:issue6lld:pubmed
pubmed-article:9538556pubmed:dateCreated1998-4-24lld:pubmed
pubmed-article:9538556pubmed:abstractTextTiming characterisation of the ECG using wavelet transforms is a new technique in which multiscale analysis reduces the influence of noise. This technique issued to investigate the effect of noise and to estimate the errors involved in the detection of onsets and offsets of ECG waves. With appropriate choice of scales of analysis, the study shows that the errors involved in the measurement of QRS width in the presence of base-line wander are negligible. The 50 Hz power-line interference introduces a maximum error of 6.25% if it is greater than 50% of the signal amplitude. The P and T complexes are not affected by power-line interference, but the base-line wander introduces a maximum error of 9.6%. In situations with the simultaneous presence of both types of noise, the use of an optimised scale restricts the errors to within clinically acceptable limits.lld:pubmed
pubmed-article:9538556pubmed:languageenglld:pubmed
pubmed-article:9538556pubmed:journalhttp://linkedlifedata.com/r...lld:pubmed
pubmed-article:9538556pubmed:citationSubsetIMlld:pubmed
pubmed-article:9538556pubmed:statusMEDLINElld:pubmed
pubmed-article:9538556pubmed:monthNovlld:pubmed
pubmed-article:9538556pubmed:issn0140-0118lld:pubmed
pubmed-article:9538556pubmed:authorpubmed-author:TandonS NSNlld:pubmed
pubmed-article:9538556pubmed:authorpubmed-author:SahambiJ SJSlld:pubmed
pubmed-article:9538556pubmed:authorpubmed-author:BhattR KRKlld:pubmed
pubmed-article:9538556pubmed:issnTypePrintlld:pubmed
pubmed-article:9538556pubmed:volume35lld:pubmed
pubmed-article:9538556pubmed:ownerNLMlld:pubmed
pubmed-article:9538556pubmed:authorsCompleteYlld:pubmed
pubmed-article:9538556pubmed:pagination747-51lld:pubmed
pubmed-article:9538556pubmed:dateRevised2004-11-17lld:pubmed
pubmed-article:9538556pubmed:meshHeadingpubmed-meshheading:9538556-...lld:pubmed
pubmed-article:9538556pubmed:meshHeadingpubmed-meshheading:9538556-...lld:pubmed
pubmed-article:9538556pubmed:meshHeadingpubmed-meshheading:9538556-...lld:pubmed
pubmed-article:9538556pubmed:meshHeadingpubmed-meshheading:9538556-...lld:pubmed
pubmed-article:9538556pubmed:meshHeadingpubmed-meshheading:9538556-...lld:pubmed
pubmed-article:9538556pubmed:year1997lld:pubmed
pubmed-article:9538556pubmed:articleTitleQuantitative analysis of errors due to power-line interference and base-line drift in detection of onsets and offsets in ECG using wavelets.lld:pubmed
pubmed-article:9538556pubmed:affiliationElectrical Engineering Department, Indian Institute of Technology, Delhi, India.lld:pubmed