pubmed-article:9261031pubmed:abstractTextThe Tesio twin catheter system (Medcomp, Harleysville, PA) was developed to overcome the problems with the existing central venous catheters in providing high-efficiency dialysis, such as inadequate blood flows, high recirculation rates, and need for surgical insertion. The relatively large internal lumens and multiple side holes in a spiral pattern allow for high blood flow rates and lower tendency to thrombosis. In this series, 82 catheter pairs were placed in 75 patients and monitored for a period encompassing 231 patient-months. We achieved mean nominal blood pump flow rates of 400 +/- 6 mL/min and an average recirculation of 4.6% +/- 0.5%. In 20 sets of catheters, a nominal blood flow rate of 388 +/- 6 mL/min was measured ultrasonically at 352 +/- 8 mL/min, representing an error of 36 +/- 5 mL/min. Thrombosis of the catheter occurred at a rate of one episode per 21 patient-months, and on all occasions responded to local instillation of urokinase. Despite having two exit sites, the infection rates were comparable to other catheters: exit site infections occurred at a rate of one per 21 patient-months and bacteremic episodes occurred at one per 11.5 patient-months, necessitating catheter removal once per 46 patient-months. Based on these data, we believe that the Tesio twin catheter system is an excellent long- and short-term vascular access for providing high-efficiency dialysis.lld:pubmed
pubmed-article:9261031pubmed:languageenglld:pubmed
pubmed-article:9261031pubmed:journalhttp://linkedlifedata.com/r...lld:pubmed
pubmed-article:9261031pubmed:citationSubsetIMlld:pubmed
pubmed-article:9261031pubmed:statusMEDLINElld:pubmed
pubmed-article:9261031pubmed:monthAuglld:pubmed
pubmed-article:9261031pubmed:issn0272-6386lld:pubmed
pubmed-article:9261031pubmed:authorpubmed-author:HawkinsI FIFlld:pubmed
pubmed-article:9261031pubmed:authorpubmed-author:RossE AEAlld:pubmed
pubmed-article:9261031pubmed:authorpubmed-author:KernsS RSRlld:pubmed
pubmed-article:9261031pubmed:authorpubmed-author:SabatelliF...lld:pubmed
pubmed-article:9261031pubmed:authorpubmed-author:PrabhuP NPNlld:pubmed
pubmed-article:9261031pubmed:issnTypePrintlld:pubmed
pubmed-article:9261031pubmed:volume30lld:pubmed
pubmed-article:9261031pubmed:ownerNLMlld:pubmed
pubmed-article:9261031pubmed:authorsCompleteYlld:pubmed
pubmed-article:9261031pubmed:pagination213-8lld:pubmed
pubmed-article:9261031pubmed:dateRevised2010-11-18lld:pubmed
pubmed-article:9261031pubmed:meshHeadingpubmed-meshheading:9261031-...lld:pubmed
pubmed-article:9261031pubmed:meshHeadingpubmed-meshheading:9261031-...lld:pubmed
pubmed-article:9261031pubmed:meshHeadingpubmed-meshheading:9261031-...lld:pubmed
pubmed-article:9261031pubmed:meshHeadingpubmed-meshheading:9261031-...lld:pubmed
pubmed-article:9261031pubmed:meshHeadingpubmed-meshheading:9261031-...lld:pubmed
pubmed-article:9261031pubmed:meshHeadingpubmed-meshheading:9261031-...lld:pubmed
pubmed-article:9261031pubmed:meshHeadingpubmed-meshheading:9261031-...lld:pubmed
pubmed-article:9261031pubmed:meshHeadingpubmed-meshheading:9261031-...lld:pubmed
pubmed-article:9261031pubmed:meshHeadingpubmed-meshheading:9261031-...lld:pubmed
pubmed-article:9261031pubmed:meshHeadingpubmed-meshheading:9261031-...lld:pubmed
pubmed-article:9261031pubmed:meshHeadingpubmed-meshheading:9261031-...lld:pubmed
pubmed-article:9261031pubmed:meshHeadingpubmed-meshheading:9261031-...lld:pubmed
pubmed-article:9261031pubmed:meshHeadingpubmed-meshheading:9261031-...lld:pubmed
pubmed-article:9261031pubmed:year1997lld:pubmed
pubmed-article:9261031pubmed:articleTitleLong-term performance and complications of the Tesio twin catheter system for hemodialysis access.lld:pubmed