Statements in which the resource exists.
SubjectPredicateObjectContext
pubmed-article:9234835rdf:typepubmed:Citationlld:pubmed
pubmed-article:9234835lifeskim:mentionsumls-concept:C1708335lld:lifeskim
pubmed-article:9234835lifeskim:mentionsumls-concept:C0221464lld:lifeskim
pubmed-article:9234835lifeskim:mentionsumls-concept:C0206162lld:lifeskim
pubmed-article:9234835lifeskim:mentionsumls-concept:C0242485lld:lifeskim
pubmed-article:9234835lifeskim:mentionsumls-concept:C0312418lld:lifeskim
pubmed-article:9234835lifeskim:mentionsumls-concept:C0205359lld:lifeskim
pubmed-article:9234835lifeskim:mentionsumls-concept:C0036667lld:lifeskim
pubmed-article:9234835lifeskim:mentionsumls-concept:C0443252lld:lifeskim
pubmed-article:9234835lifeskim:mentionsumls-concept:C1514863lld:lifeskim
pubmed-article:9234835pubmed:issue7 Pt 1lld:pubmed
pubmed-article:9234835pubmed:dateCreated1997-9-22lld:pubmed
pubmed-article:9234835pubmed:abstractTextBaroreflex sensitivity (BRS) is altered in a variety of circumstances and could be considered as a marker for the prognosis of some cardiovascular diseases. The present study was designed to evaluate the reproducibility of noninvasive measures of BRS, both at mid- and at long-term. Fourteen healthy volunteers were examined on three occasions (first interval = 1 week, second interval = 1 year). Each recording was performed using a noninvasive photoplethysmographic device (Finapres 2300, Ohmeda), both in supine and standing positions. Two different methods of measurement were used: the sequences method and cross spectral analysis. The reproducibility of BRS measures was as satisfactory at mid- as at long-term for the sequences method (intraclass coefficient [ICC] = 0.87 and 0.86, respectively), but it was better at mid- than at long-term for the cross-spectral analysis (ICC = 0.85 and 0.54, respectively). The measures performed in standing position were obviously more reproducible than those made in recumbent position (ICC = 0.87 and 0.70 for the sequences method, 0.85 and 0.71 for the cross-spectral analysis, respectively). Due to the high reproducibility of these noninvasive measures, the number of patients to be included in a pharmacological study was calculated as rather small: for example, only 20 patients are required for detecting a change in upright BRS of 3 msec/mm Hg, at long-term (sequences method). Likewise, the magnitude of the regression to the mean, which has to be expected in patients selected for a follow-up study, turned out to be low: for example, <15% of the difference between the patient group mean value and the reference value, both at mid- and at long-term (standing position, sequences method). We conclude that: 1) The noninvasive measures of BRS in standing position are reproducible enough to allow longitudinal studies to be conducted over either a short or a long period; 2) The long-term reliability of the sequences method seems to be higher than that of the cross-spectral analysis; and 3) Subtle changes in SBR may be noninvasively detected within small patient groups.lld:pubmed
pubmed-article:9234835pubmed:commentsCorrectionshttp://linkedlifedata.com/r...lld:pubmed
pubmed-article:9234835pubmed:languageenglld:pubmed
pubmed-article:9234835pubmed:journalhttp://linkedlifedata.com/r...lld:pubmed
pubmed-article:9234835pubmed:citationSubsetIMlld:pubmed
pubmed-article:9234835pubmed:statusMEDLINElld:pubmed
pubmed-article:9234835pubmed:monthJullld:pubmed
pubmed-article:9234835pubmed:issn0895-7061lld:pubmed
pubmed-article:9234835pubmed:authorpubmed-author:HerpinDDlld:pubmed
pubmed-article:9234835pubmed:authorpubmed-author:RagotSSlld:pubmed
pubmed-article:9234835pubmed:issnTypePrintlld:pubmed
pubmed-article:9234835pubmed:volume10lld:pubmed
pubmed-article:9234835pubmed:ownerNLMlld:pubmed
pubmed-article:9234835pubmed:authorsCompleteYlld:pubmed
pubmed-article:9234835pubmed:pagination790-7lld:pubmed
pubmed-article:9234835pubmed:dateRevised2009-2-24lld:pubmed
pubmed-article:9234835pubmed:meshHeadingpubmed-meshheading:9234835-...lld:pubmed
pubmed-article:9234835pubmed:meshHeadingpubmed-meshheading:9234835-...lld:pubmed
pubmed-article:9234835pubmed:meshHeadingpubmed-meshheading:9234835-...lld:pubmed
pubmed-article:9234835pubmed:meshHeadingpubmed-meshheading:9234835-...lld:pubmed
pubmed-article:9234835pubmed:meshHeadingpubmed-meshheading:9234835-...lld:pubmed
pubmed-article:9234835pubmed:meshHeadingpubmed-meshheading:9234835-...lld:pubmed
pubmed-article:9234835pubmed:meshHeadingpubmed-meshheading:9234835-...lld:pubmed
pubmed-article:9234835pubmed:meshHeadingpubmed-meshheading:9234835-...lld:pubmed
pubmed-article:9234835pubmed:meshHeadingpubmed-meshheading:9234835-...lld:pubmed
pubmed-article:9234835pubmed:meshHeadingpubmed-meshheading:9234835-...lld:pubmed
pubmed-article:9234835pubmed:meshHeadingpubmed-meshheading:9234835-...lld:pubmed
pubmed-article:9234835pubmed:meshHeadingpubmed-meshheading:9234835-...lld:pubmed
pubmed-article:9234835pubmed:year1997lld:pubmed
pubmed-article:9234835pubmed:articleTitleMid- and long-term reproducibility of noninvasive measurements of spontaneous arterial baroreflex sensitivity in healthy volunteers.lld:pubmed
pubmed-article:9234835pubmed:affiliationService Cardiologie, Centre Hospitalo-Universitaire, Poitiers, France.lld:pubmed
pubmed-article:9234835pubmed:publicationTypeJournal Articlelld:pubmed
pubmed-article:9234835pubmed:publicationTypeClinical Triallld:pubmed