pubmed-article:8847431pubmed:abstractTextTo analyze efficiency and reliability of 4 modern neonatal ventilators under difficult test conditions. The ventilators tested were: Babylog 8000 (Dräger Medical), BP 2001 (Bear Medical Systems), Sechrist IV 100 B (Sechrist Industries), Infant Star (Infrasonics INC).lld:pubmed
pubmed-article:8847431pubmed:languageenglld:pubmed
pubmed-article:8847431pubmed:journalhttp://linkedlifedata.com/r...lld:pubmed
pubmed-article:8847431pubmed:citationSubsetIMlld:pubmed
pubmed-article:8847431pubmed:statusMEDLINElld:pubmed
pubmed-article:8847431pubmed:monthSeplld:pubmed
pubmed-article:8847431pubmed:issn0342-4642lld:pubmed
pubmed-article:8847431pubmed:authorpubmed-author:CloupMMlld:pubmed
pubmed-article:8847431pubmed:authorpubmed-author:HubertPPlld:pubmed
pubmed-article:8847431pubmed:authorpubmed-author:HartWWlld:pubmed
pubmed-article:8847431pubmed:authorpubmed-author:JarreauP HPHlld:pubmed
pubmed-article:8847431pubmed:authorpubmed-author:LofasoFFlld:pubmed
pubmed-article:8847431pubmed:authorpubmed-author:JouvetPPlld:pubmed
pubmed-article:8847431pubmed:issnTypePrintlld:pubmed
pubmed-article:8847431pubmed:volume21lld:pubmed
pubmed-article:8847431pubmed:ownerNLMlld:pubmed
pubmed-article:8847431pubmed:authorsCompleteYlld:pubmed
pubmed-article:8847431pubmed:pagination753-8lld:pubmed
pubmed-article:8847431pubmed:dateRevised2006-11-15lld:pubmed
pubmed-article:8847431pubmed:meshHeadingpubmed-meshheading:8847431-...lld:pubmed
pubmed-article:8847431pubmed:meshHeadingpubmed-meshheading:8847431-...lld:pubmed
pubmed-article:8847431pubmed:meshHeadingpubmed-meshheading:8847431-...lld:pubmed
pubmed-article:8847431pubmed:meshHeadingpubmed-meshheading:8847431-...lld:pubmed
pubmed-article:8847431pubmed:meshHeadingpubmed-meshheading:8847431-...lld:pubmed
pubmed-article:8847431pubmed:meshHeadingpubmed-meshheading:8847431-...lld:pubmed
pubmed-article:8847431pubmed:meshHeadingpubmed-meshheading:8847431-...lld:pubmed
pubmed-article:8847431pubmed:meshHeadingpubmed-meshheading:8847431-...lld:pubmed
pubmed-article:8847431pubmed:meshHeadingpubmed-meshheading:8847431-...lld:pubmed
pubmed-article:8847431pubmed:year1995lld:pubmed
pubmed-article:8847431pubmed:articleTitleAssessment of neonatal ventilator performances.lld:pubmed
pubmed-article:8847431pubmed:affiliationPaediatric Intensive Care Unit, Hospital Necker Enfants Malades, Paris, France.lld:pubmed
pubmed-article:8847431pubmed:publicationTypeJournal Articlelld:pubmed
pubmed-article:8847431pubmed:publicationTypeComparative Studylld:pubmed