pubmed-article:847219pubmed:abstractTextThe delta-Scan 50 computed tomographic (CT) scanner has the ability to determine x-ray attenuation coefficients with a precision ranging from 0.3 to 2.6% depending upon such factors as patient size and scan diameter. Resolution is 20-80% greater than the pixel width, with values ranging from 1.2 to 2.1 mm. The collimating system determines certain characteristics of the image and affects the dose to the patient: doses for typical procedures are on the order of 1 rad, and gonadal doses are in the millirad range. Potential improvements are discussed.lld:pubmed
pubmed-article:847219pubmed:languageenglld:pubmed
pubmed-article:847219pubmed:journalhttp://linkedlifedata.com/r...lld:pubmed
pubmed-article:847219pubmed:citationSubsetAIMlld:pubmed
pubmed-article:847219pubmed:statusMEDLINElld:pubmed
pubmed-article:847219pubmed:monthMaylld:pubmed
pubmed-article:847219pubmed:issn0033-8419lld:pubmed
pubmed-article:847219pubmed:authorpubmed-author:KiefferS ASAlld:pubmed
pubmed-article:847219pubmed:authorpubmed-author:ChamberlainC...lld:pubmed
pubmed-article:847219pubmed:authorpubmed-author:BassanoD ADAlld:pubmed
pubmed-article:847219pubmed:authorpubmed-author:MozleyJ MJMlld:pubmed
pubmed-article:847219pubmed:issnTypePrintlld:pubmed
pubmed-article:847219pubmed:volume123lld:pubmed
pubmed-article:847219pubmed:ownerNLMlld:pubmed
pubmed-article:847219pubmed:authorsCompleteYlld:pubmed
pubmed-article:847219pubmed:pagination455-62lld:pubmed
pubmed-article:847219pubmed:dateRevised2004-11-17lld:pubmed
pubmed-article:847219pubmed:meshHeadingpubmed-meshheading:847219-H...lld:pubmed
pubmed-article:847219pubmed:meshHeadingpubmed-meshheading:847219-B...lld:pubmed
pubmed-article:847219pubmed:meshHeadingpubmed-meshheading:847219-M...lld:pubmed
pubmed-article:847219pubmed:meshHeadingpubmed-meshheading:847219-R...lld:pubmed
pubmed-article:847219pubmed:meshHeadingpubmed-meshheading:847219-T...lld:pubmed
pubmed-article:847219pubmed:meshHeadingpubmed-meshheading:847219-T...lld:pubmed
pubmed-article:847219pubmed:year1977lld:pubmed
pubmed-article:847219pubmed:articleTitlePhysical, performance, and dosimetric characteristics of the delta-Scan 50 whole-body/brain scanner.lld:pubmed