pubmed-article:8208212pubmed:abstractTextThe measurement of absorbed dose as well as dose distributions (profiles and isodose curves) for small radiation fields (as encountered in stereotactic surgery) has been difficult due to the usual large detector size or densitometer aperture (> 1 mm) relative to the radiation field (as small as 4 mm). The radiochromic direct-imaging film, when read with a scanning laser microdensitometer (laser beam diameter 0.1 mm), overcomes this difficulty and has advantages over conventional film in providing improved precision, better tissue equivalence, greater dynamic range, higher spatial resolution, and room light handling. As a demonstration of suitability, the calibrated radiochromic film has been used to measure the dose characteristics for the 18-, 14-, 8-, and 4-mm fields from the gamma-ray stereotactic surgery units at Mayo Clinic and the University of Pittsburgh. Intercomparisons of radiochromic film with conventional methods of dosimetry and vendor-supplied computational dose planning system values indicate agreement to within +/- 2%. The dose, dose profiles, and isodose curves obtained with radiochromic film can provide high-spatial-resolution information of value for acceptance testing and quality control of dose measurement and/or calculation.lld:pubmed
pubmed-article:8208212pubmed:languageenglld:pubmed
pubmed-article:8208212pubmed:journalhttp://linkedlifedata.com/r...lld:pubmed
pubmed-article:8208212pubmed:citationSubsetIMlld:pubmed
pubmed-article:8208212pubmed:statusMEDLINElld:pubmed
pubmed-article:8208212pubmed:monthMarlld:pubmed
pubmed-article:8208212pubmed:issn0094-2405lld:pubmed
pubmed-article:8208212pubmed:authorpubmed-author:WuAAlld:pubmed
pubmed-article:8208212pubmed:authorpubmed-author:KlineR WRWlld:pubmed
pubmed-article:8208212pubmed:authorpubmed-author:SayegJ AJAlld:pubmed
pubmed-article:8208212pubmed:authorpubmed-author:McCulloughE...lld:pubmed
pubmed-article:8208212pubmed:authorpubmed-author:SoaresC GCGlld:pubmed
pubmed-article:8208212pubmed:authorpubmed-author:McLaughlinW...lld:pubmed
pubmed-article:8208212pubmed:authorpubmed-author:MaitzA HAHlld:pubmed
pubmed-article:8208212pubmed:issnTypePrintlld:pubmed
pubmed-article:8208212pubmed:volume21lld:pubmed
pubmed-article:8208212pubmed:ownerNLMlld:pubmed
pubmed-article:8208212pubmed:authorsCompleteYlld:pubmed
pubmed-article:8208212pubmed:pagination379-88lld:pubmed
pubmed-article:8208212pubmed:dateRevised2004-11-17lld:pubmed
pubmed-article:8208212pubmed:meshHeadingpubmed-meshheading:8208212-...lld:pubmed
pubmed-article:8208212pubmed:meshHeadingpubmed-meshheading:8208212-...lld:pubmed
pubmed-article:8208212pubmed:meshHeadingpubmed-meshheading:8208212-...lld:pubmed
pubmed-article:8208212pubmed:meshHeadingpubmed-meshheading:8208212-...lld:pubmed
pubmed-article:8208212pubmed:year1994lld:pubmed
pubmed-article:8208212pubmed:articleTitleThe use of a radiochromic detector for the determination of stereotactic radiosurgery dose characteristics.lld:pubmed