pubmed-article:8160261 | pubmed:abstractText | An isocratic liquid-chromatographic method employing one extraction step and a 4.6 mm x 150 mm Spherisorb ODS2, 3 microns high-performance liquid chromatography (HPLC) column using ultraviolet (UV)-absorbance detection at 210 nm has been developed for quantitation of felbamate (FBM) and three felbamate metabolites in 0.100-ml aliquots of human plasma. The linear quantitation range for FBM and the two hydroxy metabolites is 0.781-200 micrograms/ml, and that for the monocarbamate metabolite is 0.391-200 micrograms/ml. | lld:pubmed |