Statements in which the resource exists.
SubjectPredicateObjectContext
pubmed-article:7815030rdf:typepubmed:Citationlld:pubmed
pubmed-article:7815030lifeskim:mentionsumls-concept:C0042037lld:lifeskim
pubmed-article:7815030lifeskim:mentionsumls-concept:C0205102lld:lifeskim
pubmed-article:7815030lifeskim:mentionsumls-concept:C0004745lld:lifeskim
pubmed-article:7815030lifeskim:mentionsumls-concept:C0184511lld:lifeskim
pubmed-article:7815030lifeskim:mentionsumls-concept:C0185115lld:lifeskim
pubmed-article:7815030lifeskim:mentionsumls-concept:C0025723lld:lifeskim
pubmed-article:7815030lifeskim:mentionsumls-concept:C0008555lld:lifeskim
pubmed-article:7815030lifeskim:mentionsumls-concept:C1442989lld:lifeskim
pubmed-article:7815030lifeskim:mentionsumls-concept:C0037813lld:lifeskim
pubmed-article:7815030lifeskim:mentionsumls-concept:C0936012lld:lifeskim
pubmed-article:7815030pubmed:issue6lld:pubmed
pubmed-article:7815030pubmed:dateCreated1995-2-3lld:pubmed
pubmed-article:7815030pubmed:abstractTextEffective solid-phase extraction, derivatization, and GC/MS procedures are developed for the simultaneous determinations of butalbital, amobarbital, pentobarbital, and secobarbital, using a deuterated pentobarbital (d5-pentobarbital) as the internal standard. Buffered (pH 7) urine samples were extracted with Bond Elute Certify II cartridge. Iodomethane/tetramethylammonium hydroxide in dimethylsulfoxide was used for methylation, while a HP 5970 MSD equipped with a 13 m J & W DB-5 column (5% phenyl polysiloxane phase) and the Thru-Put Target software package were used for GC/MS analysis and data processing. This protocol was found to be superior, in both chromatographic performance characteristics and quantitation results, over a liquid-liquid extraction procedure without derivatization using hexobarbital as the internal standard. Extraction recoveries observed from control samples containing four barbiturates range from 80% to 90%. Good one-point calibration data are obtained for all four barbiturates in the 50 to 3200 ng/mL range. Interestingly, the one-point calibration data for pentobarbital are inferior to the other three barbiturates--due to interference from the internal standard (d5-pentobarbital). The calibration data of pentobarbital are best described by a hyperbolic curve regression model. Precision data (% CV) for GC/MS analysis, over-all procedure, and day-to-day performance are approximately 2.0%, 6.0%, and 8.0%, respectively. With the use of a 2 mL sample size, the attainable detection limit is approximately 20 ng/mL.lld:pubmed
pubmed-article:7815030pubmed:languageenglld:pubmed
pubmed-article:7815030pubmed:journalhttp://linkedlifedata.com/r...lld:pubmed
pubmed-article:7815030pubmed:citationSubsetIMlld:pubmed
pubmed-article:7815030pubmed:chemicalhttp://linkedlifedata.com/r...lld:pubmed
pubmed-article:7815030pubmed:chemicalhttp://linkedlifedata.com/r...lld:pubmed
pubmed-article:7815030pubmed:chemicalhttp://linkedlifedata.com/r...lld:pubmed
pubmed-article:7815030pubmed:chemicalhttp://linkedlifedata.com/r...lld:pubmed
pubmed-article:7815030pubmed:chemicalhttp://linkedlifedata.com/r...lld:pubmed
pubmed-article:7815030pubmed:statusMEDLINElld:pubmed
pubmed-article:7815030pubmed:monthNovlld:pubmed
pubmed-article:7815030pubmed:issn0022-1198lld:pubmed
pubmed-article:7815030pubmed:authorpubmed-author:EdwardsCClld:pubmed
pubmed-article:7815030pubmed:authorpubmed-author:WaliaA SASlld:pubmed
pubmed-article:7815030pubmed:authorpubmed-author:FosterGGlld:pubmed
pubmed-article:7815030pubmed:authorpubmed-author:YIPW KWKlld:pubmed
pubmed-article:7815030pubmed:authorpubmed-author:LangnerJ GJGlld:pubmed
pubmed-article:7815030pubmed:authorpubmed-author:McKeehanA MAMlld:pubmed
pubmed-article:7815030pubmed:authorpubmed-author:BensleyW DWDlld:pubmed
pubmed-article:7815030pubmed:issnTypePrintlld:pubmed
pubmed-article:7815030pubmed:volume39lld:pubmed
pubmed-article:7815030pubmed:ownerNLMlld:pubmed
pubmed-article:7815030pubmed:authorsCompleteYlld:pubmed
pubmed-article:7815030pubmed:pagination1504-14lld:pubmed
pubmed-article:7815030pubmed:dateRevised2006-11-15lld:pubmed
pubmed-article:7815030pubmed:meshHeadingpubmed-meshheading:7815030-...lld:pubmed
pubmed-article:7815030pubmed:meshHeadingpubmed-meshheading:7815030-...lld:pubmed
pubmed-article:7815030pubmed:meshHeadingpubmed-meshheading:7815030-...lld:pubmed
pubmed-article:7815030pubmed:meshHeadingpubmed-meshheading:7815030-...lld:pubmed
pubmed-article:7815030pubmed:meshHeadingpubmed-meshheading:7815030-...lld:pubmed
pubmed-article:7815030pubmed:meshHeadingpubmed-meshheading:7815030-...lld:pubmed
pubmed-article:7815030pubmed:meshHeadingpubmed-meshheading:7815030-...lld:pubmed
pubmed-article:7815030pubmed:meshHeadingpubmed-meshheading:7815030-...lld:pubmed
pubmed-article:7815030pubmed:meshHeadingpubmed-meshheading:7815030-...lld:pubmed
pubmed-article:7815030pubmed:year1994lld:pubmed
pubmed-article:7815030pubmed:articleTitleImproved gas chromatography/mass spectrometry analysis of barbiturates in urine using centrifuge-based solid-phase extraction, methylation, with d5-pentobarbital as internal standard.lld:pubmed
pubmed-article:7815030pubmed:affiliationDepartment of Criminal Justice, University of Alabama at Birmingham.lld:pubmed
pubmed-article:7815030pubmed:publicationTypeJournal Articlelld:pubmed