Statements in which the resource exists.
SubjectPredicateObjectContext
pubmed-article:7812807rdf:typepubmed:Citationlld:pubmed
pubmed-article:7812807lifeskim:mentionsumls-concept:C0014544lld:lifeskim
pubmed-article:7812807lifeskim:mentionsumls-concept:C0150369lld:lifeskim
pubmed-article:7812807lifeskim:mentionsumls-concept:C0013819lld:lifeskim
pubmed-article:7812807lifeskim:mentionsumls-concept:C0026809lld:lifeskim
pubmed-article:7812807lifeskim:mentionsumls-concept:C0021107lld:lifeskim
pubmed-article:7812807lifeskim:mentionsumls-concept:C0449851lld:lifeskim
pubmed-article:7812807lifeskim:mentionsumls-concept:C0205191lld:lifeskim
pubmed-article:7812807pubmed:issue3lld:pubmed
pubmed-article:7812807pubmed:dateCreated1995-2-3lld:pubmed
pubmed-article:7812807pubmed:abstractTextThe implanted system was composed of four silver ball electrodes placed in the burr hole of the skull, a reference placed subcutaneously near the nose, two electrodes for EMG, and a ground. The dural attachment was 0.1 mm in diameter. A cassette connector was placed on the back. Implanted cables between the cassette connector and all electrodes consist of twisted fine wires placed in a silicone tube 0.5 mm in diameter. The implanted electrode system weighed 0.8 g. The outlet cables were of the same materials used for implanted cables and placed in a silicone tube 1.5 mm in diameter. The impedance matching between these cables was successful and assured the minimum contamination of artifacts in the EEG recording of freely moving mice. Long-term (4-5 weeks) recording, thus, became possible without damage to the implanted materials. Monopolar recordings demonstrated the localized paroxysmal discharges during general tonic clonic convulsion in El mice. Several artifacts are presented.lld:pubmed
pubmed-article:7812807pubmed:languageenglld:pubmed
pubmed-article:7812807pubmed:journalhttp://linkedlifedata.com/r...lld:pubmed
pubmed-article:7812807pubmed:citationSubsetIMlld:pubmed
pubmed-article:7812807pubmed:statusMEDLINElld:pubmed
pubmed-article:7812807pubmed:issn0361-9230lld:pubmed
pubmed-article:7812807pubmed:authorpubmed-author:SuzukiKKlld:pubmed
pubmed-article:7812807pubmed:authorpubmed-author:SaitoKKlld:pubmed
pubmed-article:7812807pubmed:authorpubmed-author:NakanoHHlld:pubmed
pubmed-article:7812807pubmed:issnTypePrintlld:pubmed
pubmed-article:7812807pubmed:volume35lld:pubmed
pubmed-article:7812807pubmed:ownerNLMlld:pubmed
pubmed-article:7812807pubmed:authorsCompleteYlld:pubmed
pubmed-article:7812807pubmed:pagination261-8lld:pubmed
pubmed-article:7812807pubmed:dateRevised2003-11-14lld:pubmed
pubmed-article:7812807pubmed:meshHeadingpubmed-meshheading:7812807-...lld:pubmed
pubmed-article:7812807pubmed:meshHeadingpubmed-meshheading:7812807-...lld:pubmed
pubmed-article:7812807pubmed:meshHeadingpubmed-meshheading:7812807-...lld:pubmed
pubmed-article:7812807pubmed:meshHeadingpubmed-meshheading:7812807-...lld:pubmed
pubmed-article:7812807pubmed:meshHeadingpubmed-meshheading:7812807-...lld:pubmed
pubmed-article:7812807pubmed:meshHeadingpubmed-meshheading:7812807-...lld:pubmed
pubmed-article:7812807pubmed:meshHeadingpubmed-meshheading:7812807-...lld:pubmed
pubmed-article:7812807pubmed:meshHeadingpubmed-meshheading:7812807-...lld:pubmed
pubmed-article:7812807pubmed:meshHeadingpubmed-meshheading:7812807-...lld:pubmed
pubmed-article:7812807pubmed:year1994lld:pubmed
pubmed-article:7812807pubmed:articleTitleChronic implantation technique for monopolar EEG monitoring of epileptic seizures in mice.lld:pubmed
pubmed-article:7812807pubmed:affiliationDepartment of Neurosurgery, National Center of Neurology and Psychiatry, Tokyo, Japan.lld:pubmed
pubmed-article:7812807pubmed:publicationTypeJournal Articlelld:pubmed
entrez-gene:111977entrezgene:pubmedpubmed-article:7812807lld:entrezgene