Statements in which the resource exists.
SubjectPredicateObjectContext
pubmed-article:7177280rdf:typepubmed:Citationlld:pubmed
pubmed-article:7177280lifeskim:mentionsumls-concept:C0014457lld:lifeskim
pubmed-article:7177280pubmed:issue1lld:pubmed
pubmed-article:7177280pubmed:dateCreated1983-2-14lld:pubmed
pubmed-article:7177280pubmed:abstractTextBlood eosinophils were counted by the counting-chamber method in 21 regular hemodialysis patients. Before dialysis, eosinophil counts were within the normal range in all patients (mean 98 cells/mm3, range 6-350). After the first 15 min of hemodialysis, with not reused coils or hollow-fiber dialysers, a significant drop in eosinophil counts was noted in all patients. The mean drop was 37.5% of the initial value (range 28-100%). At the end of the 5-hour dialysis, the eosinophil counts rose significantly in all patients but 1. The mean rise was 521% of the initial counts (range 22.3-1576%). Simultaneous neutrophil counts showed the already described drop at 15 min with a return to predialysis levels at 5 h. Predialysis IgE serum concentrations were lower than normal (mean 24.8, range 4.5-58 units/ml), and did not change at the end of the dialysis. It seems that pulmonary sequestration is responsible for both neutropenia and eosinopenia early in dialysis. The marked eosinophilia at 5 h may be the result of a release of eosinophilotactic substances induced by the dialysis procedure itself.lld:pubmed
pubmed-article:7177280pubmed:languageenglld:pubmed
pubmed-article:7177280pubmed:journalhttp://linkedlifedata.com/r...lld:pubmed
pubmed-article:7177280pubmed:citationSubsetIMlld:pubmed
pubmed-article:7177280pubmed:statusMEDLINElld:pubmed
pubmed-article:7177280pubmed:issn0028-2766lld:pubmed
pubmed-article:7177280pubmed:authorpubmed-author:ZakuthVVlld:pubmed
pubmed-article:7177280pubmed:authorpubmed-author:AviramAAlld:pubmed
pubmed-article:7177280pubmed:authorpubmed-author:PeerGGlld:pubmed
pubmed-article:7177280pubmed:authorpubmed-author:BodnerGGlld:pubmed
pubmed-article:7177280pubmed:authorpubmed-author:SpirerZ HZHlld:pubmed
pubmed-article:7177280pubmed:issnTypePrintlld:pubmed
pubmed-article:7177280pubmed:volume32lld:pubmed
pubmed-article:7177280pubmed:ownerNLMlld:pubmed
pubmed-article:7177280pubmed:authorsCompleteYlld:pubmed
pubmed-article:7177280pubmed:pagination63-6lld:pubmed
pubmed-article:7177280pubmed:dateRevised2004-11-17lld:pubmed
pubmed-article:7177280pubmed:meshHeadingpubmed-meshheading:7177280-...lld:pubmed
pubmed-article:7177280pubmed:meshHeadingpubmed-meshheading:7177280-...lld:pubmed
pubmed-article:7177280pubmed:meshHeadingpubmed-meshheading:7177280-...lld:pubmed
pubmed-article:7177280pubmed:meshHeadingpubmed-meshheading:7177280-...lld:pubmed
pubmed-article:7177280pubmed:meshHeadingpubmed-meshheading:7177280-...lld:pubmed
pubmed-article:7177280pubmed:meshHeadingpubmed-meshheading:7177280-...lld:pubmed
pubmed-article:7177280pubmed:meshHeadingpubmed-meshheading:7177280-...lld:pubmed
pubmed-article:7177280pubmed:meshHeadingpubmed-meshheading:7177280-...lld:pubmed
pubmed-article:7177280pubmed:meshHeadingpubmed-meshheading:7177280-...lld:pubmed
pubmed-article:7177280pubmed:year1982lld:pubmed
pubmed-article:7177280pubmed:articleTitleDialysis-induced eosinophilia.lld:pubmed
pubmed-article:7177280pubmed:publicationTypeJournal Articlelld:pubmed