pubmed-article:4076248 | rdf:type | pubmed:Citation | lld:pubmed |
pubmed-article:4076248 | lifeskim:mentions | umls-concept:C0543467 | lld:lifeskim |
pubmed-article:4076248 | lifeskim:mentions | umls-concept:C0018798 | lld:lifeskim |
pubmed-article:4076248 | lifeskim:mentions | umls-concept:C0021270 | lld:lifeskim |
pubmed-article:4076248 | lifeskim:mentions | umls-concept:C0242485 | lld:lifeskim |
pubmed-article:4076248 | lifeskim:mentions | umls-concept:C0428883 | lld:lifeskim |
pubmed-article:4076248 | lifeskim:mentions | umls-concept:C0439851 | lld:lifeskim |
pubmed-article:4076248 | lifeskim:mentions | umls-concept:C0039155 | lld:lifeskim |
pubmed-article:4076248 | lifeskim:mentions | umls-concept:C0444504 | lld:lifeskim |
pubmed-article:4076248 | lifeskim:mentions | umls-concept:C1707455 | lld:lifeskim |
pubmed-article:4076248 | lifeskim:mentions | umls-concept:C1979590 | lld:lifeskim |
pubmed-article:4076248 | lifeskim:mentions | umls-concept:C1552596 | lld:lifeskim |
pubmed-article:4076248 | lifeskim:mentions | umls-concept:C1947931 | lld:lifeskim |
pubmed-article:4076248 | pubmed:issue | 4 | lld:pubmed |
pubmed-article:4076248 | pubmed:dateCreated | 1986-2-18 | lld:pubmed |
pubmed-article:4076248 | pubmed:abstractText | The accuracy of indirect oscillometric blood pressure measurements has been evaluated in 32 infants up to 11 months of age undergoing heart surgery. In a number of 1029 simultaneous measurements the indirect blood pressure was compared with the direct value obtained from a radial artery catheter. Cuffs of different sizes were applied. The main results were as follows: Regarding the ratio of cuff width to arm circumference, the best correlation between oscillometric and direct blood pressure measurements was obtained with a ratio of 0.38-0.41. The value of indirect blood pressure measurements depends on the absolute height of the blood pressure. In low blood pressure there is a tendency to underestimate and in high blood pressure there is a tendency to overestimate by the oscillometric blood pressure measurement. By applying an appropriate cuff size and by using our diagrams it should be possible to derive a direct value for the blood pressure on the basis of indirect oscillometric blood pressure measurements. | lld:pubmed |
pubmed-article:4076248 | pubmed:language | eng | lld:pubmed |
pubmed-article:4076248 | pubmed:journal | http://linkedlifedata.com/r... | lld:pubmed |
pubmed-article:4076248 | pubmed:citationSubset | IM | lld:pubmed |
pubmed-article:4076248 | pubmed:status | MEDLINE | lld:pubmed |
pubmed-article:4076248 | pubmed:month | Nov | lld:pubmed |
pubmed-article:4076248 | pubmed:issn | 0340-6199 | lld:pubmed |
pubmed-article:4076248 | pubmed:author | pubmed-author:SchöberJ GJG | lld:pubmed |
pubmed-article:4076248 | pubmed:author | pubmed-author:PetersDD | lld:pubmed |
pubmed-article:4076248 | pubmed:author | pubmed-author:BühlmeyerKK | lld:pubmed |
pubmed-article:4076248 | pubmed:author | pubmed-author:PilossoffVV | lld:pubmed |
pubmed-article:4076248 | pubmed:issnType | Print | lld:pubmed |
pubmed-article:4076248 | pubmed:volume | 144 | lld:pubmed |
pubmed-article:4076248 | pubmed:owner | NLM | lld:pubmed |
pubmed-article:4076248 | pubmed:authorsComplete | Y | lld:pubmed |
pubmed-article:4076248 | pubmed:pagination | 324-30 | lld:pubmed |
pubmed-article:4076248 | pubmed:dateRevised | 2006-11-15 | lld:pubmed |
pubmed-article:4076248 | pubmed:meshHeading | pubmed-meshheading:4076248-... | lld:pubmed |
pubmed-article:4076248 | pubmed:meshHeading | pubmed-meshheading:4076248-... | lld:pubmed |
pubmed-article:4076248 | pubmed:meshHeading | pubmed-meshheading:4076248-... | lld:pubmed |
pubmed-article:4076248 | pubmed:meshHeading | pubmed-meshheading:4076248-... | lld:pubmed |
pubmed-article:4076248 | pubmed:meshHeading | pubmed-meshheading:4076248-... | lld:pubmed |
pubmed-article:4076248 | pubmed:meshHeading | pubmed-meshheading:4076248-... | lld:pubmed |
pubmed-article:4076248 | pubmed:meshHeading | pubmed-meshheading:4076248-... | lld:pubmed |
pubmed-article:4076248 | pubmed:meshHeading | pubmed-meshheading:4076248-... | lld:pubmed |
pubmed-article:4076248 | pubmed:year | 1985 | lld:pubmed |
pubmed-article:4076248 | pubmed:articleTitle | Non-invasive oscillometric measurement of systolic, mean and diastolic blood pressure in infants with congenital heart defects after operation. A comparison with direct blood pressure measurements. | lld:pubmed |
pubmed-article:4076248 | pubmed:publicationType | Journal Article | lld:pubmed |
pubmed-article:4076248 | pubmed:publicationType | Comparative Study | lld:pubmed |
pubmed-article:4076248 | pubmed:publicationType | Research Support, Non-U.S. Gov't | lld:pubmed |
http://linkedlifedata.com/r... | pubmed:referesTo | pubmed-article:4076248 | lld:pubmed |
http://linkedlifedata.com/r... | pubmed:referesTo | pubmed-article:4076248 | lld:pubmed |