pubmed-article:3955963 | pubmed:abstractText | Non-cemented press fit prostheses require a high degree of surgical precision for success. Since components vary in size by millimeters, the optimum preoperatively-determined size becomes a vital factor in selecting the correct size at the time of surgery. The preoperatively-determined component size is useful only if the information is obtained in a reliable and reproducible manner. The proper sequence combines X-rays of known magnification and templates of corresponding magnification. X-ray magnification is not a constant value even if the X-ray tube is maintained at a standardized height. Variables such as patient size and positioning make magnification measurements a necessity for every X-ray taken. A dense lead plate was designed for this purpose because commercially-available devices are over-penetrated by the X-ray exposures routinely used for hip roentgenograms. Manufacturers can provide templates in varying magnifications. This makes it possible to obtain a high correlation between the preoperative choice and the actual size chosen at surgery. | lld:pubmed |
pubmed-article:3955963 | pubmed:language | eng | lld:pubmed |
pubmed-article:3955963 | pubmed:journal | http://linkedlifedata.com/r... | lld:pubmed |
pubmed-article:3955963 | pubmed:citationSubset | AIM | lld:pubmed |
pubmed-article:3955963 | pubmed:status | MEDLINE | lld:pubmed |
pubmed-article:3955963 | pubmed:month | Jan | lld:pubmed |
pubmed-article:3955963 | pubmed:issn | 0009-921X | lld:pubmed |
pubmed-article:3955963 | pubmed:author | pubmed-author:SchwartzLL | lld:pubmed |
pubmed-article:3955963 | pubmed:author | pubmed-author:GorskiJ MJM | lld:pubmed |
pubmed-article:3955963 | pubmed:issnType | Print | lld:pubmed |
pubmed-article:3955963 | pubmed:owner | NLM | lld:pubmed |
pubmed-article:3955963 | pubmed:authorsComplete | Y | lld:pubmed |
pubmed-article:3955963 | pubmed:pagination | 302-6 | lld:pubmed |
pubmed-article:3955963 | pubmed:dateRevised | 2005-3-3 | lld:pubmed |
pubmed-article:3955963 | pubmed:meshHeading | pubmed-meshheading:3955963-... | lld:pubmed |
pubmed-article:3955963 | pubmed:meshHeading | pubmed-meshheading:3955963-... | lld:pubmed |
pubmed-article:3955963 | pubmed:meshHeading | pubmed-meshheading:3955963-... | lld:pubmed |
pubmed-article:3955963 | pubmed:meshHeading | pubmed-meshheading:3955963-... | lld:pubmed |
pubmed-article:3955963 | pubmed:meshHeading | pubmed-meshheading:3955963-... | lld:pubmed |
pubmed-article:3955963 | pubmed:year | 1986 | lld:pubmed |
pubmed-article:3955963 | pubmed:articleTitle | A device to measure X-ray magnification in preoperative planning for cementless arthroplasty. | lld:pubmed |
pubmed-article:3955963 | pubmed:publicationType | Journal Article | lld:pubmed |
http://linkedlifedata.com/r... | pubmed:referesTo | pubmed-article:3955963 | lld:pubmed |
http://linkedlifedata.com/r... | pubmed:referesTo | pubmed-article:3955963 | lld:pubmed |
http://linkedlifedata.com/r... | pubmed:referesTo | pubmed-article:3955963 | lld:pubmed |