Statements in which the resource exists.
SubjectPredicateObjectContext
pubmed-article:3169974rdf:typepubmed:Citationlld:pubmed
pubmed-article:3169974lifeskim:mentionsumls-concept:C0220825lld:lifeskim
pubmed-article:3169974lifeskim:mentionsumls-concept:C0016642lld:lifeskim
pubmed-article:3169974pubmed:issue1lld:pubmed
pubmed-article:3169974pubmed:dateCreated1988-10-31lld:pubmed
pubmed-article:3169974pubmed:abstractTextClinical evaluation of a new method for internal fixation with power-driven staples is presented. We have used the 3M staplizer for 2 years in 100 cases and the result of the fixation obtained with the titanium staples in metaphyseal bone has been very good. Ninety-six cases healed without any problems, and in 4 there was displacement. The only case with infection was successfully treated with antibiotics. We conclude that the 3M staplizer is a reliable method for internal fixation of metaphyseal bone. The staples are easily driven into the bone, reasonable stability is obtained and the method is fast and safe.lld:pubmed
pubmed-article:3169974pubmed:languageenglld:pubmed
pubmed-article:3169974pubmed:journalhttp://linkedlifedata.com/r...lld:pubmed
pubmed-article:3169974pubmed:citationSubsetIMlld:pubmed
pubmed-article:3169974pubmed:statusMEDLINElld:pubmed
pubmed-article:3169974pubmed:monthJanlld:pubmed
pubmed-article:3169974pubmed:issn0020-1383lld:pubmed
pubmed-article:3169974pubmed:authorpubmed-author:HerbertsPPlld:pubmed
pubmed-article:3169974pubmed:authorpubmed-author:OstgaardH CHClld:pubmed
pubmed-article:3169974pubmed:issnTypePrintlld:pubmed
pubmed-article:3169974pubmed:volume19lld:pubmed
pubmed-article:3169974pubmed:ownerNLMlld:pubmed
pubmed-article:3169974pubmed:authorsCompleteYlld:pubmed
pubmed-article:3169974pubmed:pagination28-30lld:pubmed
pubmed-article:3169974pubmed:dateRevised2007-11-15lld:pubmed
pubmed-article:3169974pubmed:meshHeadingpubmed-meshheading:3169974-...lld:pubmed
pubmed-article:3169974pubmed:meshHeadingpubmed-meshheading:3169974-...lld:pubmed
pubmed-article:3169974pubmed:meshHeadingpubmed-meshheading:3169974-...lld:pubmed
pubmed-article:3169974pubmed:meshHeadingpubmed-meshheading:3169974-...lld:pubmed
pubmed-article:3169974pubmed:meshHeadingpubmed-meshheading:3169974-...lld:pubmed
pubmed-article:3169974pubmed:meshHeadingpubmed-meshheading:3169974-...lld:pubmed
pubmed-article:3169974pubmed:meshHeadingpubmed-meshheading:3169974-...lld:pubmed
pubmed-article:3169974pubmed:meshHeadingpubmed-meshheading:3169974-...lld:pubmed
pubmed-article:3169974pubmed:meshHeadingpubmed-meshheading:3169974-...lld:pubmed
pubmed-article:3169974pubmed:meshHeadingpubmed-meshheading:3169974-...lld:pubmed
pubmed-article:3169974pubmed:meshHeadingpubmed-meshheading:3169974-...lld:pubmed
pubmed-article:3169974pubmed:year1988lld:pubmed
pubmed-article:3169974pubmed:articleTitleEvaluation of the 3M staplizer: a new internal fixation system.lld:pubmed
pubmed-article:3169974pubmed:affiliationDepartment of Orthopaedics, Sahlgren Hospital, Gothenburg, Sweden.lld:pubmed
pubmed-article:3169974pubmed:publicationTypeJournal Articlelld:pubmed