Statements in which the resource exists.
SubjectPredicateObjectContext
pubmed-article:2306364rdf:typepubmed:Citationlld:pubmed
pubmed-article:2306364lifeskim:mentionsumls-concept:C0543467lld:lifeskim
pubmed-article:2306364lifeskim:mentionsumls-concept:C0035203lld:lifeskim
pubmed-article:2306364lifeskim:mentionsumls-concept:C0005528lld:lifeskim
pubmed-article:2306364lifeskim:mentionsumls-concept:C0042491lld:lifeskim
pubmed-article:2306364lifeskim:mentionsumls-concept:C0015376lld:lifeskim
pubmed-article:2306364lifeskim:mentionsumls-concept:C1548223lld:lifeskim
pubmed-article:2306364lifeskim:mentionsumls-concept:C1548224lld:lifeskim
pubmed-article:2306364lifeskim:mentionsumls-concept:C0018851lld:lifeskim
pubmed-article:2306364lifeskim:mentionsumls-concept:C0001864lld:lifeskim
pubmed-article:2306364lifeskim:mentionsumls-concept:C2603343lld:lifeskim
pubmed-article:2306364lifeskim:mentionsumls-concept:C0039514lld:lifeskim
pubmed-article:2306364pubmed:issue2lld:pubmed
pubmed-article:2306364pubmed:dateCreated1990-4-9lld:pubmed
pubmed-article:2306364pubmed:abstractTextForced-air heating and air conditioning (HAC) systems caused an average and maximum increase in air infiltration rates of 1.8- and 4.3-fold, respectively, during brief whole-house studies of tracer gas decay in 39 occupied houses. An average increase in air infiltration rate of 0.33 +/- 0.37 h-1 corresponded to an incremental air leak of 240 m3/h, based on approximate house volume. More detailed tracer gas decay studies were performed in basement, kitchen and bedroom locations of six homes with low air infiltration rates (i.e., less than 0.25 h-1). The HAC mixed the indoor air efficiently between measurement sites. HAC operation also caused 1.1- to 3.6-fold increases in air infiltration rates, corresponding to absolute increases of 0.02 to 0.1 h-1. In an unoccupied research house, three-fold increases in average air infiltration rate with HAC operation (i.e., from 0.13 to 0.36 h-1) were reduced to two-fold (i.e., from 0.10 to 0.18 h-1) by sealing the external HAC unit and crawlspace ductwork system. This sealing also resulted in a 30 percent reduction in crawlspace-to-indoor transport rates with the HAC turned on. Blower door tests indicated a less than 20 percent reduction in house leakage area.lld:pubmed
pubmed-article:2306364pubmed:languageenglld:pubmed
pubmed-article:2306364pubmed:journalhttp://linkedlifedata.com/r...lld:pubmed
pubmed-article:2306364pubmed:citationSubsetIMlld:pubmed
pubmed-article:2306364pubmed:chemicalhttp://linkedlifedata.com/r...lld:pubmed
pubmed-article:2306364pubmed:statusMEDLINElld:pubmed
pubmed-article:2306364pubmed:monthFeblld:pubmed
pubmed-article:2306364pubmed:issn1047-3289lld:pubmed
pubmed-article:2306364pubmed:authorpubmed-author:MatthewsT GTGlld:pubmed
pubmed-article:2306364pubmed:authorpubmed-author:WilsonD LDLlld:pubmed
pubmed-article:2306364pubmed:authorpubmed-author:DudneyC SCSlld:pubmed
pubmed-article:2306364pubmed:authorpubmed-author:ThompsonC VCVlld:pubmed
pubmed-article:2306364pubmed:authorpubmed-author:MonarK PKPlld:pubmed
pubmed-article:2306364pubmed:issnTypePrintlld:pubmed
pubmed-article:2306364pubmed:volume40lld:pubmed
pubmed-article:2306364pubmed:ownerNLMlld:pubmed
pubmed-article:2306364pubmed:authorsCompleteYlld:pubmed
pubmed-article:2306364pubmed:pagination194-8lld:pubmed
pubmed-article:2306364pubmed:dateRevised2006-11-15lld:pubmed
pubmed-article:2306364pubmed:meshHeadingpubmed-meshheading:2306364-...lld:pubmed
pubmed-article:2306364pubmed:meshHeadingpubmed-meshheading:2306364-...lld:pubmed
pubmed-article:2306364pubmed:meshHeadingpubmed-meshheading:2306364-...lld:pubmed
pubmed-article:2306364pubmed:meshHeadingpubmed-meshheading:2306364-...lld:pubmed
pubmed-article:2306364pubmed:meshHeadingpubmed-meshheading:2306364-...lld:pubmed
pubmed-article:2306364pubmed:year1990lld:pubmed
pubmed-article:2306364pubmed:articleTitleImpact of heating and air conditioning system operation and leakage on ventilation and intercompartment transport: studies in unoccupied and occupied Tennessee Valley homes.lld:pubmed
pubmed-article:2306364pubmed:affiliationOak Ridge National Laboratory, Tennessee.lld:pubmed
pubmed-article:2306364pubmed:publicationTypeJournal Articlelld:pubmed
pubmed-article:2306364pubmed:publicationTypeResearch Support, U.S. Gov't, Non-P.H.S.lld:pubmed
pubmed-article:2306364pubmed:publicationTypeResearch Support, Non-U.S. Gov'tlld:pubmed
http://linkedlifedata.com/r...pubmed:referesTopubmed-article:2306364lld:pubmed