pubmed-article:2132546pubmed:abstractTextA versatile closed micro-perfusion chamber designed for single-cell fluorescence measurements under maximum microscopic magnification is described. Glass coverslips with adherent cells can be attached to the top or bottom of the chamber, depending on whether an inverted or an upright microscope is used. Eight conical holes drilled in the side of the chamber serve for the insertion of plugs with attachments for perfusion, rapid injection of small amounts of reagents, temperature measurements or for heating the interior of the chamber. Materials used in the construction of the chamber are non-toxic and resistant to standard sterilization procedures. Perfusion and temperature properties of the chamber are described. Single cell fluorescence measurements are presented in human monocyte-derived macrophages in which NAD(P)H and intracellular calcium are measured.lld:pubmed
pubmed-article:2132546pubmed:commentsCorrectionshttp://linkedlifedata.com/r...lld:pubmed
pubmed-article:2132546pubmed:languageenglld:pubmed
pubmed-article:2132546pubmed:journalhttp://linkedlifedata.com/r...lld:pubmed
pubmed-article:2132546pubmed:citationSubsetIMlld:pubmed
pubmed-article:2132546pubmed:chemicalhttp://linkedlifedata.com/r...lld:pubmed
pubmed-article:2132546pubmed:chemicalhttp://linkedlifedata.com/r...lld:pubmed
pubmed-article:2132546pubmed:statusMEDLINElld:pubmed
pubmed-article:2132546pubmed:monthAprlld:pubmed
pubmed-article:2132546pubmed:issn0022-1759lld:pubmed
pubmed-article:2132546pubmed:authorpubmed-author:InceCClld:pubmed
pubmed-article:2132546pubmed:authorpubmed-author:BeekmanR ERElld:pubmed
pubmed-article:2132546pubmed:authorpubmed-author:VerschragenGGlld:pubmed
pubmed-article:2132546pubmed:issnTypePrintlld:pubmed
pubmed-article:2132546pubmed:day17lld:pubmed
pubmed-article:2132546pubmed:volume128lld:pubmed
pubmed-article:2132546pubmed:ownerNLMlld:pubmed
pubmed-article:2132546pubmed:authorsCompleteYlld:pubmed
pubmed-article:2132546pubmed:pagination227-34lld:pubmed
pubmed-article:2132546pubmed:dateRevised2004-11-17lld:pubmed
pubmed-article:2132546pubmed:meshHeadingpubmed-meshheading:2132546-...lld:pubmed
pubmed-article:2132546pubmed:meshHeadingpubmed-meshheading:2132546-...lld:pubmed
pubmed-article:2132546pubmed:meshHeadingpubmed-meshheading:2132546-...lld:pubmed
pubmed-article:2132546pubmed:meshHeadingpubmed-meshheading:2132546-...lld:pubmed
pubmed-article:2132546pubmed:meshHeadingpubmed-meshheading:2132546-...lld:pubmed
pubmed-article:2132546pubmed:meshHeadingpubmed-meshheading:2132546-...lld:pubmed
pubmed-article:2132546pubmed:meshHeadingpubmed-meshheading:2132546-...lld:pubmed
pubmed-article:2132546pubmed:meshHeadingpubmed-meshheading:2132546-...lld:pubmed
pubmed-article:2132546pubmed:meshHeadingpubmed-meshheading:2132546-...lld:pubmed
pubmed-article:2132546pubmed:meshHeadingpubmed-meshheading:2132546-...lld:pubmed
pubmed-article:2132546pubmed:meshHeadingpubmed-meshheading:2132546-...lld:pubmed
pubmed-article:2132546pubmed:meshHeadingpubmed-meshheading:2132546-...lld:pubmed
pubmed-article:2132546pubmed:year1990lld:pubmed
pubmed-article:2132546pubmed:articleTitleA micro-perfusion chamber for single-cell fluorescence measurements.lld:pubmed
pubmed-article:2132546pubmed:affiliationDepartment of Surgery, Erasmus University, Rotterdam, The Netherlands.lld:pubmed
pubmed-article:2132546pubmed:publicationTypeJournal Articlelld:pubmed
http://linkedlifedata.com/r...pubmed:referesTopubmed-article:2132546lld:pubmed
http://linkedlifedata.com/r...pubmed:referesTopubmed-article:2132546lld:pubmed