Statements in which the resource exists.
SubjectPredicateObjectContext
pubmed-article:21293973rdf:typepubmed:Citationlld:pubmed
pubmed-article:21293973lifeskim:mentionsumls-concept:C0026336lld:lifeskim
pubmed-article:21293973lifeskim:mentionsumls-concept:C0015811lld:lifeskim
pubmed-article:21293973lifeskim:mentionsumls-concept:C0043309lld:lifeskim
pubmed-article:21293973lifeskim:mentionsumls-concept:C0205463lld:lifeskim
pubmed-article:21293973lifeskim:mentionsumls-concept:C0441722lld:lifeskim
pubmed-article:21293973lifeskim:mentionsumls-concept:C0162462lld:lifeskim
pubmed-article:21293973lifeskim:mentionsumls-concept:C2826285lld:lifeskim
pubmed-article:21293973pubmed:issue6lld:pubmed
pubmed-article:21293973pubmed:dateCreated2011-5-18lld:pubmed
pubmed-article:21293973pubmed:abstractTextHigh resolution in vivo velocity measurements within the cardiovascular system are essential for accurate calculation of vessel wall shear stress, a highly influential factor for the progression of arterial disease. Unfortunately, currently available techniques for in vivo imaging are unable to provide the temporal resolution required for velocity measurement at physiological flow rates. Advances in technology and improvements in imaging systems are allowing a relatively new technique, X-ray velocimetry, to become a viable tool for such measurements. This study investigates the haemodynamics of pulsatile blood flow in an optically opaque in vitro model at physiological flow rates using X-ray velocimetry. The in vitro model, an asymmetric stenosis, is designed as a 3:1 femoral artery with the diameter and flow rate replicating vasculature of a mouse. Velocity measurements are obtained over multiple cycles of the periodic flow at high temporal and spatial resolution (1 ms and 29 ?m, respectively) allowing accurate measurement of the velocity gradients and calculation of the wall shear stress. This study clearly illustrates the capability of in vitro X-ray velocimetry, suggesting it as a possible measurement technique for future in vivo vascular wall shear stress measurement.lld:pubmed
pubmed-article:21293973pubmed:languageenglld:pubmed
pubmed-article:21293973pubmed:journalhttp://linkedlifedata.com/r...lld:pubmed
pubmed-article:21293973pubmed:citationSubsetIMlld:pubmed
pubmed-article:21293973pubmed:statusMEDLINElld:pubmed
pubmed-article:21293973pubmed:monthJunlld:pubmed
pubmed-article:21293973pubmed:issn1521-6047lld:pubmed
pubmed-article:21293973pubmed:authorpubmed-author:SiuKaren K...lld:pubmed
pubmed-article:21293973pubmed:authorpubmed-author:HouriganKerry...lld:pubmed
pubmed-article:21293973pubmed:authorpubmed-author:FourasAndreas...lld:pubmed
pubmed-article:21293973pubmed:authorpubmed-author:DubskyStephen...lld:pubmed
pubmed-article:21293973pubmed:authorpubmed-author:JamisonR...lld:pubmed
pubmed-article:21293973pubmed:issnTypeElectroniclld:pubmed
pubmed-article:21293973pubmed:volume39lld:pubmed
pubmed-article:21293973pubmed:ownerNLMlld:pubmed
pubmed-article:21293973pubmed:authorsCompleteYlld:pubmed
pubmed-article:21293973pubmed:pagination1643-53lld:pubmed
pubmed-article:21293973pubmed:meshHeadingpubmed-meshheading:21293973...lld:pubmed
pubmed-article:21293973pubmed:meshHeadingpubmed-meshheading:21293973...lld:pubmed
pubmed-article:21293973pubmed:meshHeadingpubmed-meshheading:21293973...lld:pubmed
pubmed-article:21293973pubmed:meshHeadingpubmed-meshheading:21293973...lld:pubmed
pubmed-article:21293973pubmed:meshHeadingpubmed-meshheading:21293973...lld:pubmed
pubmed-article:21293973pubmed:meshHeadingpubmed-meshheading:21293973...lld:pubmed
pubmed-article:21293973pubmed:meshHeadingpubmed-meshheading:21293973...lld:pubmed
pubmed-article:21293973pubmed:meshHeadingpubmed-meshheading:21293973...lld:pubmed
pubmed-article:21293973pubmed:year2011lld:pubmed
pubmed-article:21293973pubmed:articleTitleX-ray velocimetry and haemodynamic forces within a stenosed femoral model at physiological flow rates.lld:pubmed
pubmed-article:21293973pubmed:affiliationDivision of Biological Engineering, Monash University, Victoria, 3800, Australia.lld:pubmed
pubmed-article:21293973pubmed:publicationTypeJournal Articlelld:pubmed
pubmed-article:21293973pubmed:publicationTypeResearch Support, Non-U.S. Gov'tlld:pubmed