Statements in which the resource exists.
SubjectPredicateObjectContext
pubmed-article:20690874rdf:typepubmed:Citationlld:pubmed
pubmed-article:20690874lifeskim:mentionsumls-concept:C0030705lld:lifeskim
pubmed-article:20690874lifeskim:mentionsumls-concept:C0521329lld:lifeskim
pubmed-article:20690874lifeskim:mentionsumls-concept:C1428349lld:lifeskim
pubmed-article:20690874lifeskim:mentionsumls-concept:C0007578lld:lifeskim
pubmed-article:20690874lifeskim:mentionsumls-concept:C0410702lld:lifeskim
pubmed-article:20690874lifeskim:mentionsumls-concept:C1413078lld:lifeskim
pubmed-article:20690874lifeskim:mentionsumls-concept:C1527177lld:lifeskim
pubmed-article:20690874lifeskim:mentionsumls-concept:C0162517lld:lifeskim
pubmed-article:20690874lifeskim:mentionsumls-concept:C0441513lld:lifeskim
pubmed-article:20690874lifeskim:mentionsumls-concept:C0029365lld:lifeskim
pubmed-article:20690874lifeskim:mentionsumls-concept:C1328260lld:lifeskim
pubmed-article:20690874lifeskim:mentionsumls-concept:C0870840lld:lifeskim
pubmed-article:20690874lifeskim:mentionsumls-concept:C0713465lld:lifeskim
pubmed-article:20690874pubmed:issue1lld:pubmed
pubmed-article:20690874pubmed:dateCreated2011-1-4lld:pubmed
pubmed-article:20690874pubmed:abstractTextABSTRACT Spinal orthoses are commonly prescribed to patients with moderate adolescent idiopathic scoliosis (AIS) for prevention of further curve deterioration. In conventional manufacturing method, plaster bandages are used to obtain the patient's body contour and then the plaster cast is rectified manually. With computer-aided design and computer-aided manufacture (CAD/CAM) system, a series of automated processes from body scanning to digital rectification and milling of the positive model can be performed in a fast and accurate fashion. The purpose of this manuscript is to introduce the application of CAD/CAM system to the construction of spinal orthosis for patients with AIS. Based on evidence within the literature, CAD/CAM method can achieve similar clinical outcomes but with higher efficiency than the conventional fabrication method. Therefore, CAD/CAM method should be considered a substitute to the conventional method in fabrication of spinal orthoses for patients with AIS.lld:pubmed
pubmed-article:20690874pubmed:languageenglld:pubmed
pubmed-article:20690874pubmed:journalhttp://linkedlifedata.com/r...lld:pubmed
pubmed-article:20690874pubmed:citationSubsetIMlld:pubmed
pubmed-article:20690874pubmed:statusMEDLINElld:pubmed
pubmed-article:20690874pubmed:monthJanlld:pubmed
pubmed-article:20690874pubmed:issn1532-5040lld:pubmed
pubmed-article:20690874pubmed:authorpubmed-author:WongM SMSlld:pubmed
pubmed-article:20690874pubmed:issnTypeElectroniclld:pubmed
pubmed-article:20690874pubmed:volume27lld:pubmed
pubmed-article:20690874pubmed:ownerNLMlld:pubmed
pubmed-article:20690874pubmed:authorsCompleteYlld:pubmed
pubmed-article:20690874pubmed:pagination74-9lld:pubmed
pubmed-article:20690874pubmed:meshHeadingpubmed-meshheading:20690874...lld:pubmed
pubmed-article:20690874pubmed:meshHeadingpubmed-meshheading:20690874...lld:pubmed
pubmed-article:20690874pubmed:meshHeadingpubmed-meshheading:20690874...lld:pubmed
pubmed-article:20690874pubmed:meshHeadingpubmed-meshheading:20690874...lld:pubmed
pubmed-article:20690874pubmed:meshHeadingpubmed-meshheading:20690874...lld:pubmed
pubmed-article:20690874pubmed:meshHeadingpubmed-meshheading:20690874...lld:pubmed
pubmed-article:20690874pubmed:meshHeadingpubmed-meshheading:20690874...lld:pubmed
pubmed-article:20690874pubmed:meshHeadingpubmed-meshheading:20690874...lld:pubmed
pubmed-article:20690874pubmed:meshHeadingpubmed-meshheading:20690874...lld:pubmed
pubmed-article:20690874pubmed:meshHeadingpubmed-meshheading:20690874...lld:pubmed
pubmed-article:20690874pubmed:meshHeadingpubmed-meshheading:20690874...lld:pubmed
pubmed-article:20690874pubmed:meshHeadingpubmed-meshheading:20690874...lld:pubmed
pubmed-article:20690874pubmed:meshHeadingpubmed-meshheading:20690874...lld:pubmed
pubmed-article:20690874pubmed:year2011lld:pubmed
pubmed-article:20690874pubmed:articleTitleComputer-aided design and computer-aided manufacture (CAD/CAM) system for construction of spinal orthosis for patients with adolescent idiopathic scoliosis.lld:pubmed
pubmed-article:20690874pubmed:affiliationDepartment of Health Technology and Informatics, The Hong Kong Polytechnic University, Hong Kong, China. m.s.wong@polyu.edu.hklld:pubmed
pubmed-article:20690874pubmed:publicationTypeJournal Articlelld:pubmed