pubmed-article:20411075 | pubmed:abstractText | Heart failure is one of the leading causes of death in the U.S. The incorporation of B-type natriuretic peptide (BNP) measurements when triaging patients presenting with shortness of breath has improved the diagnostic and prognostic ability of physicians. Currently, there are no point-of-care systems for quantifying BNP that can be used without sacrificing accuracy. We compared the analytical performance of the Abbott i-STAT analyzer, a handheld point-of-care system for measuring BNP, with the lab-based system, the Abbott ARCHITECT. | lld:pubmed |
pubmed-article:20411075 | pubmed:commentsCorrections | http://linkedlifedata.com/r... | lld:pubmed |
pubmed-article:20411075 | pubmed:commentsCorrections | http://linkedlifedata.com/r... | lld:pubmed |
pubmed-article:20411075 | pubmed:commentsCorrections | http://linkedlifedata.com/r... | lld:pubmed |
pubmed-article:20411075 | pubmed:commentsCorrections | http://linkedlifedata.com/r... | lld:pubmed |
pubmed-article:20411075 | pubmed:commentsCorrections | http://linkedlifedata.com/r... | lld:pubmed |
pubmed-article:20411075 | pubmed:commentsCorrections | http://linkedlifedata.com/r... | lld:pubmed |
pubmed-article:20411075 | pubmed:commentsCorrections | http://linkedlifedata.com/r... | lld:pubmed |
pubmed-article:20411075 | pubmed:commentsCorrections | http://linkedlifedata.com/r... | lld:pubmed |
pubmed-article:20411075 | pubmed:commentsCorrections | http://linkedlifedata.com/r... | lld:pubmed |
pubmed-article:20411075 | pubmed:commentsCorrections | http://linkedlifedata.com/r... | lld:pubmed |
pubmed-article:20411075 | pubmed:commentsCorrections | http://linkedlifedata.com/r... | lld:pubmed |
pubmed-article:20411075 | pubmed:language | eng | lld:pubmed |
pubmed-article:20411075 | pubmed:journal | http://linkedlifedata.com/r... | lld:pubmed |
pubmed-article:20411075 | pubmed:status | PubMed-not-MEDLINE | lld:pubmed |
pubmed-article:20411075 | pubmed:month | Feb | lld:pubmed |
pubmed-article:20411075 | pubmed:issn | 1936-9018 | lld:pubmed |
pubmed-article:20411075 | pubmed:author | pubmed-author:MaiselAlan... | lld:pubmed |
pubmed-article:20411075 | pubmed:author | pubmed-author:FitzgeraldRob... | lld:pubmed |
pubmed-article:20411075 | pubmed:author | pubmed-author:JiangKevinK | lld:pubmed |
pubmed-article:20411075 | pubmed:author | pubmed-author:ShahKevinK | lld:pubmed |
pubmed-article:20411075 | pubmed:author | pubmed-author:TerraccianoGa... | lld:pubmed |
pubmed-article:20411075 | pubmed:issnType | Electronic | lld:pubmed |
pubmed-article:20411075 | pubmed:volume | 11 | lld:pubmed |
pubmed-article:20411075 | pubmed:owner | NLM | lld:pubmed |
pubmed-article:20411075 | pubmed:authorsComplete | Y | lld:pubmed |
pubmed-article:20411075 | pubmed:pagination | 44-8 | lld:pubmed |
pubmed-article:20411075 | pubmed:year | 2010 | lld:pubmed |
pubmed-article:20411075 | pubmed:articleTitle | Comparability of Results between Point-of-Care and Automated Instruments to Measure B-type Natriuretic Peptide. | lld:pubmed |
pubmed-article:20411075 | pubmed:affiliation | Veterans Administration San Diego Healthcare System, Cardiology, La Jolla, CA. | lld:pubmed |
pubmed-article:20411075 | pubmed:publicationType | Journal Article | lld:pubmed |
http://linkedlifedata.com/r... | pubmed:referesTo | pubmed-article:20411075 | lld:pubmed |