Statements in which the resource exists.
SubjectPredicateObjectContext
pubmed-article:20139267rdf:typepubmed:Citationlld:pubmed
pubmed-article:20139267lifeskim:mentionsumls-concept:C0030705lld:lifeskim
pubmed-article:20139267lifeskim:mentionsumls-concept:C0441833lld:lifeskim
pubmed-article:20139267lifeskim:mentionsumls-concept:C0178602lld:lifeskim
pubmed-article:20139267lifeskim:mentionsumls-concept:C0851346lld:lifeskim
pubmed-article:20139267lifeskim:mentionsumls-concept:C1999270lld:lifeskim
pubmed-article:20139267lifeskim:mentionsumls-concept:C0392756lld:lifeskim
pubmed-article:20139267lifeskim:mentionsumls-concept:C0180392lld:lifeskim
pubmed-article:20139267lifeskim:mentionsumls-concept:C1555765lld:lifeskim
pubmed-article:20139267lifeskim:mentionsumls-concept:C0205324lld:lifeskim
pubmed-article:20139267pubmed:issue1-3lld:pubmed
pubmed-article:20139267pubmed:dateCreated2010-5-11lld:pubmed
pubmed-article:20139267pubmed:abstractTextAn internal audit has been performed to evaluate the patient radiation dose in the clinical use of X-ray cardiac flat panel detector (FPD) systems. Fluoroscopy and image acquisition (cine mode) programs are optimised for low-dose settings. The diagnostic and therapeutic interventional cardiac procedures are performed at 6 pulse s(-1) for fluoroscopy and 15 frames s(-1) for image acquisition. The FPD entrance dose is configured for 29 nGy pulse(-1) in the fluoroscopy mode and 0.10 microGy frame(-1) in the cine mode. From the data collected, the following local reference levels for coronary angiography and angioplasty have been obtained: kerma-area products 23 and 44 Gy cm(2), cumulative doses 376 and 776 mGy, fluoroscopy times 5 and 15.5 min and cine images 617 and 1163 images.lld:pubmed
pubmed-article:20139267pubmed:languageenglld:pubmed
pubmed-article:20139267pubmed:journalhttp://linkedlifedata.com/r...lld:pubmed
pubmed-article:20139267pubmed:citationSubsetIMlld:pubmed
pubmed-article:20139267pubmed:statusMEDLINElld:pubmed
pubmed-article:20139267pubmed:issn1742-3406lld:pubmed
pubmed-article:20139267pubmed:authorpubmed-author:BeisselJJlld:pubmed
pubmed-article:20139267pubmed:authorpubmed-author:DragusinOOlld:pubmed
pubmed-article:20139267pubmed:authorpubmed-author:BokouCClld:pubmed
pubmed-article:20139267pubmed:authorpubmed-author:BreischRRlld:pubmed
pubmed-article:20139267pubmed:issnTypeElectroniclld:pubmed
pubmed-article:20139267pubmed:volume139lld:pubmed
pubmed-article:20139267pubmed:ownerNLMlld:pubmed
pubmed-article:20139267pubmed:authorsCompleteYlld:pubmed
pubmed-article:20139267pubmed:pagination266-70lld:pubmed
pubmed-article:20139267pubmed:meshHeadingpubmed-meshheading:20139267...lld:pubmed
pubmed-article:20139267pubmed:meshHeadingpubmed-meshheading:20139267...lld:pubmed
pubmed-article:20139267pubmed:meshHeadingpubmed-meshheading:20139267...lld:pubmed
pubmed-article:20139267pubmed:meshHeadingpubmed-meshheading:20139267...lld:pubmed
pubmed-article:20139267pubmed:meshHeadingpubmed-meshheading:20139267...lld:pubmed
pubmed-article:20139267pubmed:meshHeadingpubmed-meshheading:20139267...lld:pubmed
pubmed-article:20139267pubmed:meshHeadingpubmed-meshheading:20139267...lld:pubmed
pubmed-article:20139267pubmed:meshHeadingpubmed-meshheading:20139267...lld:pubmed
pubmed-article:20139267pubmed:meshHeadingpubmed-meshheading:20139267...lld:pubmed
pubmed-article:20139267pubmed:meshHeadingpubmed-meshheading:20139267...lld:pubmed
pubmed-article:20139267pubmed:meshHeadingpubmed-meshheading:20139267...lld:pubmed
pubmed-article:20139267pubmed:articleTitleDoes a flat panel detector reduce the patient radiation dose in interventional cardiology?lld:pubmed
pubmed-article:20139267pubmed:affiliationEntente des Hôpitaux Luxembourgeois, 5 rue des Mérovingiens, L-8070 Bertrange, Luxembourg. octavian.dragusin@ehl.lulld:pubmed
pubmed-article:20139267pubmed:publicationTypeJournal Articlelld:pubmed
pubmed-article:20139267pubmed:publicationTypeComparative Studylld:pubmed