pubmed-article:2002383pubmed:abstractTextThe reliability of localization of interictal spike sources using magnetoencephalography (MEG) was examined by repeated measurements in a patient with temporal lobe epilepsy. During two preoperative recording sessions, the estimated sources, projected onto magnetic resonance images of the patient's brain, were found to lie less than 1 cm apart within the area subsequently resected. The MEG localization was in close agreement with intraoperative cortical recordings.lld:pubmed
pubmed-article:2002383pubmed:languageenglld:pubmed
pubmed-article:2002383pubmed:journalhttp://linkedlifedata.com/r...lld:pubmed
pubmed-article:2002383pubmed:citationSubsetAIMlld:pubmed
pubmed-article:2002383pubmed:statusMEDLINElld:pubmed
pubmed-article:2002383pubmed:monthAprlld:pubmed
pubmed-article:2002383pubmed:issn0022-3085lld:pubmed
pubmed-article:2002383pubmed:authorpubmed-author:BrownL MLMlld:pubmed
pubmed-article:2002383pubmed:authorpubmed-author:EisenbergH...lld:pubmed
pubmed-article:2002383pubmed:authorpubmed-author:RogersR LRLlld:pubmed
pubmed-article:2002383pubmed:authorpubmed-author:PapanicolaouA...lld:pubmed
pubmed-article:2002383pubmed:authorpubmed-author:BaumannS BSBlld:pubmed
pubmed-article:2002383pubmed:issnTypePrintlld:pubmed
pubmed-article:2002383pubmed:volume74lld:pubmed
pubmed-article:2002383pubmed:ownerNLMlld:pubmed
pubmed-article:2002383pubmed:authorsCompleteYlld:pubmed
pubmed-article:2002383pubmed:pagination660-4lld:pubmed
pubmed-article:2002383pubmed:dateRevised2006-11-15lld:pubmed
pubmed-article:2002383pubmed:meshHeadingpubmed-meshheading:2002383-...lld:pubmed
pubmed-article:2002383pubmed:meshHeadingpubmed-meshheading:2002383-...lld:pubmed
pubmed-article:2002383pubmed:meshHeadingpubmed-meshheading:2002383-...lld:pubmed
pubmed-article:2002383pubmed:meshHeadingpubmed-meshheading:2002383-...lld:pubmed
pubmed-article:2002383pubmed:meshHeadingpubmed-meshheading:2002383-...lld:pubmed
pubmed-article:2002383pubmed:meshHeadingpubmed-meshheading:2002383-...lld:pubmed
pubmed-article:2002383pubmed:meshHeadingpubmed-meshheading:2002383-...lld:pubmed
pubmed-article:2002383pubmed:year1991lld:pubmed
pubmed-article:2002383pubmed:articleTitleMagnetoencephalographic localization of interictal spike sources. Case report.lld:pubmed
pubmed-article:2002383pubmed:affiliationMagnetoencephalography Laboratory, University of Texas Medical Branch, Galveston.lld:pubmed
pubmed-article:2002383pubmed:publicationTypeJournal Articlelld:pubmed
pubmed-article:2002383pubmed:publicationTypeCase Reportslld:pubmed
pubmed-article:2002383pubmed:publicationTypeResearch Support, Non-U.S. Gov'tlld:pubmed