pubmed-article:18305594 | pubmed:abstractText | A grazing-incidence interferometer for the testing of technical surfaces for macroscopic surface deviations is described. Computer-generated holograms serve as beam splitters and references for the workpieces tested. The sensitivity of the interferometer depends on the period of the computer-generated holograms. The method is demonstrated at a rod object of convex profile. Using phase-stepping techniques, the grazing-incidence interferometer provides fast measurements of the entire mantle surface of the test sample with submicrometer precision. | lld:pubmed |