Statements in which the resource exists.
SubjectPredicateObjectContext
pubmed-article:18280408rdf:typepubmed:Citationlld:pubmed
pubmed-article:18280408lifeskim:mentionsumls-concept:C0242767lld:lifeskim
pubmed-article:18280408lifeskim:mentionsumls-concept:C1186763lld:lifeskim
pubmed-article:18280408lifeskim:mentionsumls-concept:C1274040lld:lifeskim
pubmed-article:18280408pubmed:issue2lld:pubmed
pubmed-article:18280408pubmed:dateCreated2008-2-18lld:pubmed
pubmed-article:18280408pubmed:abstractTextDespite excellent results, failure of osseointegration does occur in femoral revisions performed with extensively porous-coated stems. This study examined the outcome of rerevision of a failed extensively porous-coated femoral stem with yet another extensively porous-coated stem. Between 1980 and 2000, we performed 711 femoral revisions using an extensively porous-coated device. Fifteen patients (16 hips) were known to have undergone a rerevision of this femoral component using another porous-coated stem. At latest follow-up, 2 patients (3 hips) were deceased, leaving 13 patients. At a mean follow-up of 9.8 years, none of the cementless stems had required another revision (100% survivorship), and 12 (92%) of the 13 stems were bone ingrown based on radiographic examination.lld:pubmed
pubmed-article:18280408pubmed:languageenglld:pubmed
pubmed-article:18280408pubmed:journalhttp://linkedlifedata.com/r...lld:pubmed
pubmed-article:18280408pubmed:citationSubsetIMlld:pubmed
pubmed-article:18280408pubmed:statusMEDLINElld:pubmed
pubmed-article:18280408pubmed:monthFeblld:pubmed
pubmed-article:18280408pubmed:issn0883-5403lld:pubmed
pubmed-article:18280408pubmed:authorpubmed-author:HamiltonWilli...lld:pubmed
pubmed-article:18280408pubmed:authorpubmed-author:EnghCharles...lld:pubmed
pubmed-article:18280408pubmed:authorpubmed-author:McAuleyJames...lld:pubmed
pubmed-article:18280408pubmed:authorpubmed-author:TabaraeeEhsan...lld:pubmed
pubmed-article:18280408pubmed:issnTypePrintlld:pubmed
pubmed-article:18280408pubmed:volume23lld:pubmed
pubmed-article:18280408pubmed:ownerNLMlld:pubmed
pubmed-article:18280408pubmed:authorsCompleteYlld:pubmed
pubmed-article:18280408pubmed:pagination170-4lld:pubmed
pubmed-article:18280408pubmed:meshHeadingpubmed-meshheading:18280408...lld:pubmed
pubmed-article:18280408pubmed:meshHeadingpubmed-meshheading:18280408...lld:pubmed
pubmed-article:18280408pubmed:meshHeadingpubmed-meshheading:18280408...lld:pubmed
pubmed-article:18280408pubmed:meshHeadingpubmed-meshheading:18280408...lld:pubmed
pubmed-article:18280408pubmed:meshHeadingpubmed-meshheading:18280408...lld:pubmed
pubmed-article:18280408pubmed:meshHeadingpubmed-meshheading:18280408...lld:pubmed
pubmed-article:18280408pubmed:meshHeadingpubmed-meshheading:18280408...lld:pubmed
pubmed-article:18280408pubmed:meshHeadingpubmed-meshheading:18280408...lld:pubmed
pubmed-article:18280408pubmed:meshHeadingpubmed-meshheading:18280408...lld:pubmed
pubmed-article:18280408pubmed:meshHeadingpubmed-meshheading:18280408...lld:pubmed
pubmed-article:18280408pubmed:meshHeadingpubmed-meshheading:18280408...lld:pubmed
pubmed-article:18280408pubmed:meshHeadingpubmed-meshheading:18280408...lld:pubmed
pubmed-article:18280408pubmed:meshHeadingpubmed-meshheading:18280408...lld:pubmed
pubmed-article:18280408pubmed:meshHeadingpubmed-meshheading:18280408...lld:pubmed
pubmed-article:18280408pubmed:year2008lld:pubmed
pubmed-article:18280408pubmed:articleTitleThe outcome of rerevision of an extensively porous-coated stem with another extensively porous-coated stem.lld:pubmed
pubmed-article:18280408pubmed:affiliationAnderson Orthopaedic Research Institute, Alexandria, Virginia 22306, USA.lld:pubmed
pubmed-article:18280408pubmed:publicationTypeJournal Articlelld:pubmed
pubmed-article:18280408pubmed:publicationTypeResearch Support, Non-U.S. Gov'tlld:pubmed