pubmed-article:1774475pubmed:abstractTextMany studies on a skeletal muscle pump (SMP) for use as a cardiac assist device require preconditioning as a countermeasure to muscle fatigue. However, we conducted experiments in the hope of developing a cardiac assist device with an alternate-drive SMP system requiring no preconditioning. Adult mongrel dogs were used. We prepared a roll-type SMP from a pedicled muscle flap of the latissimus dorsi and major pectoris muscle, and an insert type SMP without separating the latissimus dorsi and major pectoris muscle. The muscles were stimulated at a frequency of 60 rpm at cycles of burst stimulation. Thirty-minute intermittent driving was performed. The hydrodynamic changes were measured at five-minute intervals for a total of three hours. The function of the pumps markedly declined after a few minutes of driving the roll-type SMPs but remained satisfactory after thirty minutes of driving the insert-type SMPs. Consequently, we concluded that dual SMPs, alternately driven through thirty minute intermittent drive and rest intervals, could be useful as cardiac assist devices without preconditioning.lld:pubmed
pubmed-article:1774475pubmed:languagejpnlld:pubmed
pubmed-article:1774475pubmed:journalhttp://linkedlifedata.com/r...lld:pubmed
pubmed-article:1774475pubmed:citationSubsetIMlld:pubmed
pubmed-article:1774475pubmed:statusMEDLINElld:pubmed
pubmed-article:1774475pubmed:monthNovlld:pubmed
pubmed-article:1774475pubmed:issn0369-4739lld:pubmed
pubmed-article:1774475pubmed:authorpubmed-author:IshimaruSSlld:pubmed
pubmed-article:1774475pubmed:authorpubmed-author:ShimizuHHlld:pubmed
pubmed-article:1774475pubmed:authorpubmed-author:HirayamaTTlld:pubmed
pubmed-article:1774475pubmed:authorpubmed-author:FurukawaKKlld:pubmed
pubmed-article:1774475pubmed:authorpubmed-author:FujikawaTTlld:pubmed
pubmed-article:1774475pubmed:authorpubmed-author:OsadaKKlld:pubmed
pubmed-article:1774475pubmed:authorpubmed-author:SuesadaHHlld:pubmed
pubmed-article:1774475pubmed:issnTypePrintlld:pubmed
pubmed-article:1774475pubmed:volume39lld:pubmed
pubmed-article:1774475pubmed:ownerNLMlld:pubmed
pubmed-article:1774475pubmed:authorsCompleteYlld:pubmed
pubmed-article:1774475pubmed:pagination1995-2001lld:pubmed
pubmed-article:1774475pubmed:dateRevised2011-7-27lld:pubmed
pubmed-article:1774475pubmed:meshHeadingpubmed-meshheading:1774475-...lld:pubmed
pubmed-article:1774475pubmed:meshHeadingpubmed-meshheading:1774475-...lld:pubmed
pubmed-article:1774475pubmed:meshHeadingpubmed-meshheading:1774475-...lld:pubmed
pubmed-article:1774475pubmed:meshHeadingpubmed-meshheading:1774475-...lld:pubmed
pubmed-article:1774475pubmed:meshHeadingpubmed-meshheading:1774475-...lld:pubmed
pubmed-article:1774475pubmed:meshHeadingpubmed-meshheading:1774475-...lld:pubmed
pubmed-article:1774475pubmed:year1991lld:pubmed
pubmed-article:1774475pubmed:articleTitle[Cardiac assist device with inserted alternate-drive skeletal muscle pump system].lld:pubmed
pubmed-article:1774475pubmed:affiliationSecond Department of Surgery, Tokyo Medical College, Japan.lld:pubmed
pubmed-article:1774475pubmed:publicationTypeJournal Articlelld:pubmed
pubmed-article:1774475pubmed:publicationTypeEnglish Abstractlld:pubmed