Statements in which the resource exists.
SubjectPredicateObjectContext
pubmed-article:17388176rdf:typepubmed:Citationlld:pubmed
pubmed-article:17388176lifeskim:mentionsumls-concept:C0028263lld:lifeskim
pubmed-article:17388176lifeskim:mentionsumls-concept:C1704922lld:lifeskim
pubmed-article:17388176lifeskim:mentionsumls-concept:C1414855lld:lifeskim
pubmed-article:17388176lifeskim:mentionsumls-concept:C1416926lld:lifeskim
pubmed-article:17388176lifeskim:mentionsumls-concept:C0002045lld:lifeskim
pubmed-article:17388176lifeskim:mentionsumls-concept:C2348043lld:lifeskim
pubmed-article:17388176lifeskim:mentionsumls-concept:C2699488lld:lifeskim
pubmed-article:17388176pubmed:issue2lld:pubmed
pubmed-article:17388176pubmed:dateCreated2007-3-28lld:pubmed
pubmed-article:17388176pubmed:abstractTextThis paper presents a comparison between an analytical and a statistical iterative reconstruction algorithm for computed transmission tomography concerning their noise and resolution performance. The reconstruction of two-dimensional images from simulated fan-beam transmission data is performed with a filtered back-projection (FBP) type reconstruction and an iterative ordered subsets convex (OSC) maximum-likelihood method. A special software phantom, which allows measuring the resolution and noise in a nonambiguous way, is used to simulate transmission tomography scans with different signal-to-noise ratios (SNR). The noise and modulation transfer function is calculated for FBP and OSC reconstruction at several positions, distributed over the field-of-view (FOV). The reconstruction with OSC using different numbers of subsets shows an inverse linear relation to the number of iterations that are necessary to reach a certain resolution and SNR, i.e., increasing the number of subsets by a factor x reduces the number of required iterations by the same factor. The OSC algorithm is able to achieve a nearly homogeneous high resolution over the whole FOV, which is not achieved with FBP. The OSC method achieves a lower level of noise compared with FBP at the same resolution. The reconstruction with OSC can save a factor of up to nine of x-ray dose compared with FBP in the investigated range of noise levels.lld:pubmed
pubmed-article:17388176pubmed:languageenglld:pubmed
pubmed-article:17388176pubmed:journalhttp://linkedlifedata.com/r...lld:pubmed
pubmed-article:17388176pubmed:citationSubsetIMlld:pubmed
pubmed-article:17388176pubmed:statusMEDLINElld:pubmed
pubmed-article:17388176pubmed:monthFeblld:pubmed
pubmed-article:17388176pubmed:issn0094-2405lld:pubmed
pubmed-article:17388176pubmed:authorpubmed-author:ZieglerAAlld:pubmed
pubmed-article:17388176pubmed:authorpubmed-author:KöhlerTTlld:pubmed
pubmed-article:17388176pubmed:authorpubmed-author:ProksaRRlld:pubmed
pubmed-article:17388176pubmed:issnTypePrintlld:pubmed
pubmed-article:17388176pubmed:volume34lld:pubmed
pubmed-article:17388176pubmed:ownerNLMlld:pubmed
pubmed-article:17388176pubmed:authorsCompleteYlld:pubmed
pubmed-article:17388176pubmed:pagination585-98lld:pubmed
pubmed-article:17388176pubmed:meshHeadingpubmed-meshheading:17388176...lld:pubmed
pubmed-article:17388176pubmed:meshHeadingpubmed-meshheading:17388176...lld:pubmed
pubmed-article:17388176pubmed:meshHeadingpubmed-meshheading:17388176...lld:pubmed
pubmed-article:17388176pubmed:meshHeadingpubmed-meshheading:17388176...lld:pubmed
pubmed-article:17388176pubmed:meshHeadingpubmed-meshheading:17388176...lld:pubmed
pubmed-article:17388176pubmed:meshHeadingpubmed-meshheading:17388176...lld:pubmed
pubmed-article:17388176pubmed:meshHeadingpubmed-meshheading:17388176...lld:pubmed
pubmed-article:17388176pubmed:meshHeadingpubmed-meshheading:17388176...lld:pubmed
pubmed-article:17388176pubmed:year2007lld:pubmed
pubmed-article:17388176pubmed:articleTitleNoise and resolution in images reconstructed with FBP and OSC algorithms for CT.lld:pubmed
pubmed-article:17388176pubmed:affiliationPhilips Research Europe, Röntgenstrasse 24-26, 22315 Hamburg, Germany.lld:pubmed
pubmed-article:17388176pubmed:publicationTypeJournal Articlelld:pubmed
pubmed-article:17388176pubmed:publicationTypeEvaluation Studieslld:pubmed
http://linkedlifedata.com/r...pubmed:referesTopubmed-article:17388176lld:pubmed
http://linkedlifedata.com/r...pubmed:referesTopubmed-article:17388176lld:pubmed