Statements in which the resource exists.
SubjectPredicateObjectContext
pubmed-article:16419025rdf:typepubmed:Citationlld:pubmed
pubmed-article:16419025lifeskim:mentionsumls-concept:C0220806lld:lifeskim
pubmed-article:16419025lifeskim:mentionsumls-concept:C0034721lld:lifeskim
pubmed-article:16419025lifeskim:mentionsumls-concept:C0034693lld:lifeskim
pubmed-article:16419025lifeskim:mentionsumls-concept:C0025663lld:lifeskim
pubmed-article:16419025lifeskim:mentionsumls-concept:C0032105lld:lifeskim
pubmed-article:16419025lifeskim:mentionsumls-concept:C0004180lld:lifeskim
pubmed-article:16419025lifeskim:mentionsumls-concept:C0577559lld:lifeskim
pubmed-article:16419025lifeskim:mentionsumls-concept:C0073633lld:lifeskim
pubmed-article:16419025lifeskim:mentionsumls-concept:C0596801lld:lifeskim
pubmed-article:16419025lifeskim:mentionsumls-concept:C0008565lld:lifeskim
pubmed-article:16419025lifeskim:mentionsumls-concept:C1709793lld:lifeskim
pubmed-article:16419025lifeskim:mentionsumls-concept:C0439831lld:lifeskim
pubmed-article:16419025lifeskim:mentionsumls-concept:C0205352lld:lifeskim
pubmed-article:16419025lifeskim:mentionsumls-concept:C0332324lld:lifeskim
pubmed-article:16419025pubmed:issue4lld:pubmed
pubmed-article:16419025pubmed:dateCreated2006-2-7lld:pubmed
pubmed-article:16419025pubmed:abstractTextA sensitive and specific method using liquid chromatography with atmospheric pressure chemical ionization mass spectrometry (LC/APCI-MS) has been developed and validated for the identification and quantification of Ranolazine in rat plasma. A simple liquid-liquid extraction procedure was followed by injection of the extracts onto a C18 column with isocratic elution and detection using a single quadrupole mass spectrometer in selected ion monitoring (SIM) mode. The method was tested using six different batches of blank plasma. Linearity was established for the concentration range 0.02-10.0 microg/mL, with a coefficient of determination (r) of 0.9998 and good back-calculated accuracy and precision. The intra- and inter-day precision (relative standard deviation (RSD) %) was lower than 10%, and accuracy ranged from 85 to 115%. The lower limit of quantification was reproducible at 0.01 microg/mL with 20 microL plasma. The proposed method enables the unambiguous identification and quantification of Ranolazine for pre-clinical and clinical studies.lld:pubmed
pubmed-article:16419025pubmed:languageenglld:pubmed
pubmed-article:16419025pubmed:journalhttp://linkedlifedata.com/r...lld:pubmed
pubmed-article:16419025pubmed:citationSubsetIMlld:pubmed
pubmed-article:16419025pubmed:chemicalhttp://linkedlifedata.com/r...lld:pubmed
pubmed-article:16419025pubmed:chemicalhttp://linkedlifedata.com/r...lld:pubmed
pubmed-article:16419025pubmed:chemicalhttp://linkedlifedata.com/r...lld:pubmed
pubmed-article:16419025pubmed:statusMEDLINElld:pubmed
pubmed-article:16419025pubmed:issn0951-4198lld:pubmed
pubmed-article:16419025pubmed:authorpubmed-author:SzeS HSHlld:pubmed
pubmed-article:16419025pubmed:authorpubmed-author:LuTongTlld:pubmed
pubmed-article:16419025pubmed:authorpubmed-author:WangGuang-JiG...lld:pubmed
pubmed-article:16419025pubmed:authorpubmed-author:LiangYanYlld:pubmed
pubmed-article:16419025pubmed:authorpubmed-author:ChenWei-DongW...lld:pubmed
pubmed-article:16419025pubmed:authorpubmed-author:LiuXiao-DongX...lld:pubmed
pubmed-article:16419025pubmed:authorpubmed-author:YeXiongXlld:pubmed
pubmed-article:16419025pubmed:copyrightInfoCopyright 2006 John Wiley & Sons, Ltd.lld:pubmed
pubmed-article:16419025pubmed:issnTypePrintlld:pubmed
pubmed-article:16419025pubmed:volume20lld:pubmed
pubmed-article:16419025pubmed:ownerNLMlld:pubmed
pubmed-article:16419025pubmed:authorsCompleteYlld:pubmed
pubmed-article:16419025pubmed:pagination523-8lld:pubmed
pubmed-article:16419025pubmed:dateRevised2007-11-15lld:pubmed
pubmed-article:16419025pubmed:meshHeadingpubmed-meshheading:16419025...lld:pubmed
pubmed-article:16419025pubmed:meshHeadingpubmed-meshheading:16419025...lld:pubmed
pubmed-article:16419025pubmed:meshHeadingpubmed-meshheading:16419025...lld:pubmed
pubmed-article:16419025pubmed:meshHeadingpubmed-meshheading:16419025...lld:pubmed
pubmed-article:16419025pubmed:meshHeadingpubmed-meshheading:16419025...lld:pubmed
pubmed-article:16419025pubmed:meshHeadingpubmed-meshheading:16419025...lld:pubmed
pubmed-article:16419025pubmed:meshHeadingpubmed-meshheading:16419025...lld:pubmed
pubmed-article:16419025pubmed:meshHeadingpubmed-meshheading:16419025...lld:pubmed
pubmed-article:16419025pubmed:meshHeadingpubmed-meshheading:16419025...lld:pubmed
pubmed-article:16419025pubmed:meshHeadingpubmed-meshheading:16419025...lld:pubmed
pubmed-article:16419025pubmed:meshHeadingpubmed-meshheading:16419025...lld:pubmed
pubmed-article:16419025pubmed:meshHeadingpubmed-meshheading:16419025...lld:pubmed
pubmed-article:16419025pubmed:meshHeadingpubmed-meshheading:16419025...lld:pubmed
pubmed-article:16419025pubmed:year2006lld:pubmed
pubmed-article:16419025pubmed:articleTitleSimple, sensitive and rapid liquid chromatography/atmospheric pressure chemical ionization mass spectrometric method for the quantitation of Ranolazine in rat plasma.lld:pubmed
pubmed-article:16419025pubmed:affiliationKey Laboratory of Drug Metabolism and Pharmacokinetics, China Pharmaceutical University, Nanjing 210009, PR China.lld:pubmed
pubmed-article:16419025pubmed:publicationTypeJournal Articlelld:pubmed