Statements in which the resource exists.
SubjectPredicateObjectContext
pubmed-article:16266090rdf:typepubmed:Citationlld:pubmed
pubmed-article:16266090lifeskim:mentionsumls-concept:C1962945lld:lifeskim
pubmed-article:16266090lifeskim:mentionsumls-concept:C1322271lld:lifeskim
pubmed-article:16266090lifeskim:mentionsumls-concept:C0026597lld:lifeskim
pubmed-article:16266090pubmed:issue9lld:pubmed
pubmed-article:16266090pubmed:dateCreated2005-11-3lld:pubmed
pubmed-article:16266090pubmed:abstractTextCurrent methods for imaging joint motion are limited to either two-dimensional (2D) video fluoroscopy, or to animated motions from a series of static three-dimensional (3D) images. 3D movement patterns can be detected from biplane fluoroscopy images matched with computed tomography images. This involves several x-ray modalities and sophisticated 2D to 3D matching for the complex wrist joint. We present a method for the acquisition of dynamic 3D images of a moving joint. In our method a 3D-rotational x-ray (3D-RX) system is used to image a cyclically moving joint. The cyclic motion is synchronized to the x-ray acquisition to yield multiple sets of projection images, which are reconstructed to a series of time resolved 3D images, i.e., four-dimensional rotational x ray (4D-RX). To investigate the obtained image quality parameters the full width at half maximum (FWHM) of the point spread function (PSF) via the edge spread function and the contrast to noise ratio between air and phantom were determined on reconstructions of a bullet and rod phantom, using 4D-RX as well as stationary 3D-RX images. The CNR in volume reconstructions based on 251 projection images in the static situation and on 41 and 34 projection images of a moving phantom were 6.9, 3.0, and 2.9, respectively. The average FWHM of the PSF of these same images was, respectively, 1.1, 1.7, and 2.2 mm orthogonal to the motion and parallel to direction of motion 0.6, 0.7, and 1.0 mm. The main deterioration of 4D-RX images compared to 3D-RX images is due to the low number of projection images used and not to the motion of the object. Using 41 projection images seems the best setting for the current system. Experiments on a postmortem wrist show the feasibility of the method for imaging 3D dynamic joint motion. We expect that 4D-RX will pave the way to improved assessment of joint disorders by detection of 3D dynamic motion patterns in joints.lld:pubmed
pubmed-article:16266090pubmed:languageenglld:pubmed
pubmed-article:16266090pubmed:journalhttp://linkedlifedata.com/r...lld:pubmed
pubmed-article:16266090pubmed:citationSubsetIMlld:pubmed
pubmed-article:16266090pubmed:statusMEDLINElld:pubmed
pubmed-article:16266090pubmed:monthSeplld:pubmed
pubmed-article:16266090pubmed:issn0094-2405lld:pubmed
pubmed-article:16266090pubmed:authorpubmed-author:KakoiMMlld:pubmed
pubmed-article:16266090pubmed:authorpubmed-author:BakkerNiels...lld:pubmed
pubmed-article:16266090pubmed:authorpubmed-author:GrimbergenCor...lld:pubmed
pubmed-article:16266090pubmed:authorpubmed-author:StreekstraGee...lld:pubmed
pubmed-article:16266090pubmed:authorpubmed-author:StrackeeSimon...lld:pubmed
pubmed-article:16266090pubmed:authorpubmed-author:CarelsenBartBlld:pubmed
pubmed-article:16266090pubmed:authorpubmed-author:BoonSjirk NSNlld:pubmed
pubmed-article:16266090pubmed:authorpubmed-author:SabczynskiJör...lld:pubmed
pubmed-article:16266090pubmed:issnTypePrintlld:pubmed
pubmed-article:16266090pubmed:volume32lld:pubmed
pubmed-article:16266090pubmed:ownerNLMlld:pubmed
pubmed-article:16266090pubmed:authorsCompleteYlld:pubmed
pubmed-article:16266090pubmed:pagination2771-6lld:pubmed
pubmed-article:16266090pubmed:meshHeadingpubmed-meshheading:16266090...lld:pubmed
pubmed-article:16266090pubmed:meshHeadingpubmed-meshheading:16266090...lld:pubmed
pubmed-article:16266090pubmed:meshHeadingpubmed-meshheading:16266090...lld:pubmed
pubmed-article:16266090pubmed:meshHeadingpubmed-meshheading:16266090...lld:pubmed
pubmed-article:16266090pubmed:meshHeadingpubmed-meshheading:16266090...lld:pubmed
pubmed-article:16266090pubmed:meshHeadingpubmed-meshheading:16266090...lld:pubmed
pubmed-article:16266090pubmed:year2005lld:pubmed
pubmed-article:16266090pubmed:articleTitle4D rotational x-ray imaging of wrist joint dynamic motion.lld:pubmed
pubmed-article:16266090pubmed:affiliationDepartment of Medical Physics, Academic Medical Center, PO Box 22660, 1100 DD Amsterdam, The Netherlands. b.carelsen@amc.uva.nllld:pubmed
pubmed-article:16266090pubmed:publicationTypeJournal Articlelld:pubmed
http://linkedlifedata.com/r...pubmed:referesTopubmed-article:16266090lld:pubmed