Statements in which the resource exists.
SubjectPredicateObjectContext
pubmed-article:16105159rdf:typepubmed:Citationlld:pubmed
pubmed-article:16105159lifeskim:mentionsumls-concept:C0030705lld:lifeskim
pubmed-article:16105159lifeskim:mentionsumls-concept:C0229671lld:lifeskim
pubmed-article:16105159lifeskim:mentionsumls-concept:C0948089lld:lifeskim
pubmed-article:16105159lifeskim:mentionsumls-concept:C0522086lld:lifeskim
pubmed-article:16105159lifeskim:mentionsumls-concept:C0039593lld:lifeskim
pubmed-article:16105159lifeskim:mentionsumls-concept:C1511790lld:lifeskim
pubmed-article:16105159lifeskim:mentionsumls-concept:C0392762lld:lifeskim
pubmed-article:16105159lifeskim:mentionsumls-concept:C1524063lld:lifeskim
pubmed-article:16105159lifeskim:mentionsumls-concept:C0750491lld:lifeskim
pubmed-article:16105159pubmed:issue9lld:pubmed
pubmed-article:16105159pubmed:dateCreated2005-8-17lld:pubmed
pubmed-article:16105159pubmed:abstractTextWe compared a third generation quantitative cardiac troponin T (cTnT) point-of-care testing (POCT) from Roche Diagnostics with the laboratory assay (Roche Elecsys 2010 immunoassay analyser). Heparin-treated blood and serum were collected simultaneously in 133 unselected patients (mean age 62 +/- 14 years, 38% females) presenting to our hospital with possible cardiac chest pain. Results of the POCT were measured against the laboratory-based assay considered as the gold standard. There were 18 POCT positive versus 24 laboratory assay positive (> or = 0.03 ng/mL) patients. POCT was falsely negative in six patients, with values between 0.03 and 0.1 ng/mL. The POCT had a sensitivity of 75%, specificity of 100%, positive predictive value of 100%, negative predictive value of 95% and a total accuracy of 95%; kappa = 0.831 (P < 0.001). There was good correlation between the values of POCT and the laboratory assay: Y = 1.195X + 0.002, r2 = 0.94 (P < 0.0001). Whereas cTnT levels > 0.1 mg/mL were reliably detected with this current generation of POCT, cTnT levels between 0.03 and 0.10 ng/mL were not. Future generations of devices will need to improve sensitivity to reliably risk stratify patients with suspected acute coronary syndromes.lld:pubmed
pubmed-article:16105159pubmed:languageenglld:pubmed
pubmed-article:16105159pubmed:journalhttp://linkedlifedata.com/r...lld:pubmed
pubmed-article:16105159pubmed:citationSubsetIMlld:pubmed
pubmed-article:16105159pubmed:chemicalhttp://linkedlifedata.com/r...lld:pubmed
pubmed-article:16105159pubmed:chemicalhttp://linkedlifedata.com/r...lld:pubmed
pubmed-article:16105159pubmed:statusMEDLINElld:pubmed
pubmed-article:16105159pubmed:monthSeplld:pubmed
pubmed-article:16105159pubmed:issn1444-0903lld:pubmed
pubmed-article:16105159pubmed:authorpubmed-author:LeungD YDYlld:pubmed
pubmed-article:16105159pubmed:authorpubmed-author:NewlandEElld:pubmed
pubmed-article:16105159pubmed:authorpubmed-author:JuergensC PCPlld:pubmed
pubmed-article:16105159pubmed:authorpubmed-author:HallaniHHlld:pubmed
pubmed-article:16105159pubmed:issnTypePrintlld:pubmed
pubmed-article:16105159pubmed:volume35lld:pubmed
pubmed-article:16105159pubmed:ownerNLMlld:pubmed
pubmed-article:16105159pubmed:authorsCompleteYlld:pubmed
pubmed-article:16105159pubmed:pagination560-2lld:pubmed
pubmed-article:16105159pubmed:dateRevised2006-11-15lld:pubmed
pubmed-article:16105159pubmed:meshHeadingpubmed-meshheading:16105159...lld:pubmed
pubmed-article:16105159pubmed:meshHeadingpubmed-meshheading:16105159...lld:pubmed
pubmed-article:16105159pubmed:meshHeadingpubmed-meshheading:16105159...lld:pubmed
pubmed-article:16105159pubmed:meshHeadingpubmed-meshheading:16105159...lld:pubmed
pubmed-article:16105159pubmed:meshHeadingpubmed-meshheading:16105159...lld:pubmed
pubmed-article:16105159pubmed:meshHeadingpubmed-meshheading:16105159...lld:pubmed
pubmed-article:16105159pubmed:meshHeadingpubmed-meshheading:16105159...lld:pubmed
pubmed-article:16105159pubmed:meshHeadingpubmed-meshheading:16105159...lld:pubmed
pubmed-article:16105159pubmed:meshHeadingpubmed-meshheading:16105159...lld:pubmed
pubmed-article:16105159pubmed:meshHeadingpubmed-meshheading:16105159...lld:pubmed
pubmed-article:16105159pubmed:meshHeadingpubmed-meshheading:16105159...lld:pubmed
pubmed-article:16105159pubmed:meshHeadingpubmed-meshheading:16105159...lld:pubmed
pubmed-article:16105159pubmed:year2005lld:pubmed
pubmed-article:16105159pubmed:articleTitleUse of a quantitative point-of-care test for the detection of serum cardiac troponin T in patients with suspected acute coronary syndromes.lld:pubmed
pubmed-article:16105159pubmed:affiliationDepartment of Cardiology, Liverpool Hospital, Sydney, New South Wales, Australia. hallanhi@wahs.nsw.gov.aulld:pubmed
pubmed-article:16105159pubmed:publicationTypeJournal Articlelld:pubmed
pubmed-article:16105159pubmed:publicationTypeComparative Studylld:pubmed