Statements in which the resource exists.
SubjectPredicateObjectContext
pubmed-article:15686997rdf:typepubmed:Citationlld:pubmed
pubmed-article:15686997lifeskim:mentionsumls-concept:C0086418lld:lifeskim
pubmed-article:15686997lifeskim:mentionsumls-concept:C0032105lld:lifeskim
pubmed-article:15686997lifeskim:mentionsumls-concept:C0680730lld:lifeskim
pubmed-article:15686997lifeskim:mentionsumls-concept:C0185115lld:lifeskim
pubmed-article:15686997lifeskim:mentionsumls-concept:C1334306lld:lifeskim
pubmed-article:15686997lifeskim:mentionsumls-concept:C0870883lld:lifeskim
pubmed-article:15686997lifeskim:mentionsumls-concept:C1171350lld:lifeskim
pubmed-article:15686997lifeskim:mentionsumls-concept:C0599748lld:lifeskim
pubmed-article:15686997lifeskim:mentionsumls-concept:C1148554lld:lifeskim
pubmed-article:15686997lifeskim:mentionsumls-concept:C0008565lld:lifeskim
pubmed-article:15686997lifeskim:mentionsumls-concept:C0679622lld:lifeskim
pubmed-article:15686997lifeskim:mentionsumls-concept:C0205314lld:lifeskim
pubmed-article:15686997lifeskim:mentionsumls-concept:C0521115lld:lifeskim
pubmed-article:15686997pubmed:issue2lld:pubmed
pubmed-article:15686997pubmed:dateCreated2005-2-2lld:pubmed
pubmed-article:15686997pubmed:abstractTextTo support pharmacokinetic studies, a selective and sensitive liquid chromatography/tandem mass spectrometry (LC-MS/MS) method has been developed and validated for the simultaneous determination of a novel KDR kinase inhibitor (1) and its active metabolite (2) in human plasma. The method is fully automated using a Packard MultiPROBE II system and a TomTec Quadra 96 liquid handling workstation to perform sample preparation and solid-phase extraction (SPE). Following the extraction on a mixed-mode SPE using Oasis MCX 96-well plate, the analytes were separated on a Aquasil C18 column (50 mm x 2.1 mm, i.d., 3 microm) with a mobile phase consisting of acetonitrile/ammonium acetate buffer (5 mM, pH 5.0) (60/40, v/v). The run time for each injection was 4.5 min with the retention times of approximately 2.0 and 2.7 min for 1 and 2 respectively, at a flow rate of 0.25 mL/min. A tandem mass spectrometric detection was conducted using multiple reaction monitoring (MRM) under the positive ion mode with a turbo ion-spray interface. The linear ranges of the calibration curves were 0.05-400 ng/mL for 1 and 0.1-400 ng/mL for 2 on a PE Sciex API 4000 LC-MS/MS system. The lower limits of quantitation (LLOQ) of the assay were 0.05 and 0.1 ng/mL for 1 and 2 respectively, when 0.4 mL of plasma was processed. Intra-day assay precision (using five standard curves prepared by spiking compounds to five lots of plasma) was less than 4.9% for 1 and less than 9.6% for 2 on each concentration. Assay accuracy was found to be 95.1-104.6% of nominal for 1 standards and 93.5-105.6% for 2 standards. QC samples were stable when kept at room temperature for 4 h, at -70 degrees C for 10 days, and after three freeze-thaw cycles. The extraction recoveries were 80%, 83% and 84% for 1 and 2 and I.S. respectively, and no significant matrix effects were observed. The method was successfully applied to plasma samples from clinical studies after oral administration of compound 1.lld:pubmed
pubmed-article:15686997pubmed:languageenglld:pubmed
pubmed-article:15686997pubmed:journalhttp://linkedlifedata.com/r...lld:pubmed
pubmed-article:15686997pubmed:citationSubsetIMlld:pubmed
pubmed-article:15686997pubmed:chemicalhttp://linkedlifedata.com/r...lld:pubmed
pubmed-article:15686997pubmed:chemicalhttp://linkedlifedata.com/r...lld:pubmed
pubmed-article:15686997pubmed:chemicalhttp://linkedlifedata.com/r...lld:pubmed
pubmed-article:15686997pubmed:statusMEDLINElld:pubmed
pubmed-article:15686997pubmed:monthMarlld:pubmed
pubmed-article:15686997pubmed:issn1570-0232lld:pubmed
pubmed-article:15686997pubmed:authorpubmed-author:MussonDonald...lld:pubmed
pubmed-article:15686997pubmed:authorpubmed-author:YangXuXlld:pubmed
pubmed-article:15686997pubmed:authorpubmed-author:DeanDennis...lld:pubmed
pubmed-article:15686997pubmed:authorpubmed-author:BraunMatthew...lld:pubmed
pubmed-article:15686997pubmed:authorpubmed-author:DuLihongLlld:pubmed
pubmed-article:15686997pubmed:authorpubmed-author:SoliEric DEDlld:pubmed
pubmed-article:15686997pubmed:issnTypePrintlld:pubmed
pubmed-article:15686997pubmed:day25lld:pubmed
pubmed-article:15686997pubmed:volume817lld:pubmed
pubmed-article:15686997pubmed:ownerNLMlld:pubmed
pubmed-article:15686997pubmed:authorsCompleteYlld:pubmed
pubmed-article:15686997pubmed:pagination287-96lld:pubmed
pubmed-article:15686997pubmed:dateRevised2006-11-15lld:pubmed
pubmed-article:15686997pubmed:meshHeadingpubmed-meshheading:15686997...lld:pubmed
pubmed-article:15686997pubmed:meshHeadingpubmed-meshheading:15686997...lld:pubmed
pubmed-article:15686997pubmed:meshHeadingpubmed-meshheading:15686997...lld:pubmed
pubmed-article:15686997pubmed:meshHeadingpubmed-meshheading:15686997...lld:pubmed
pubmed-article:15686997pubmed:meshHeadingpubmed-meshheading:15686997...lld:pubmed
pubmed-article:15686997pubmed:meshHeadingpubmed-meshheading:15686997...lld:pubmed
pubmed-article:15686997pubmed:meshHeadingpubmed-meshheading:15686997...lld:pubmed
pubmed-article:15686997pubmed:meshHeadingpubmed-meshheading:15686997...lld:pubmed
pubmed-article:15686997pubmed:year2005lld:pubmed
pubmed-article:15686997pubmed:articleTitleSimultaneous determination of a novel KDR kinase inhibitor and its N-oxide metabolite in human plasma using 96-well solid-phase extraction and liquid chromatography/tandem mass spectrometry.lld:pubmed
pubmed-article:15686997pubmed:affiliationMerck Research Laboratories, Department of Drug Metabolism, WP75A-303, West Point, PA 19486, USA. yang_xu@merck.comlld:pubmed
pubmed-article:15686997pubmed:publicationTypeJournal Articlelld:pubmed