Statements in which the resource exists.
SubjectPredicateObjectContext
pubmed-article:15477740rdf:typepubmed:Citationlld:pubmed
pubmed-article:15477740lifeskim:mentionsumls-concept:C1527148lld:lifeskim
pubmed-article:15477740lifeskim:mentionsumls-concept:C0002154lld:lifeskim
pubmed-article:15477740lifeskim:mentionsumls-concept:C0185125lld:lifeskim
pubmed-article:15477740lifeskim:mentionsumls-concept:C1879848lld:lifeskim
pubmed-article:15477740lifeskim:mentionsumls-concept:C1879746lld:lifeskim
pubmed-article:15477740lifeskim:mentionsumls-concept:C1547011lld:lifeskim
pubmed-article:15477740pubmed:issue8lld:pubmed
pubmed-article:15477740pubmed:dateCreated2004-10-12lld:pubmed
pubmed-article:15477740pubmed:abstractTextTi-based biocompatible alloys are especially used for replacing failed hard tissue. Some of the most actively investigated materials for medical implants are the beta-Ti alloys, as they have a low elastic modulus (to inhibit bone resorption). They are alloyed with elements such as Nb, Ta, Zr, Mo, and Fe. We have prepared a new beta-Ti alloy that combines Ti with the non-toxic elements Ta and Mo using a vacuum arc-melting furnace and then annealed at 950 degrees C for one hour. The alloy was finally quenched in water at room temperature. The Ti-12Mo-5Ta alloy was characterised by X-ray diffraction, optical microscopy, SEM and EDS and found to have a body-centred-cubic structure (beta-type). It had a lower Young's modulus (about 74 GPa) than the classical alpha/beta Ti-6Al-4V alloy (120 GPa), while its Vickers hardness remained very high (about 303 HV). This makes it a good compromise for a use as a bone substitute. The cytocompatibility of samples of Ti-12Mo-5Ta and Ti-6Al-4V titanium alloys with various surface roughnesses was assessed in vitro using organotypic cultures of bone tissue and quantitative analyses of cell migration, proliferation and adhesion. Mechanically polished surfaces were prepared to produce unorientated residual polished grooves and cells grew to a particularly high density on the smoother Ti-12Mo-5Ta surface tested.lld:pubmed
pubmed-article:15477740pubmed:languageenglld:pubmed
pubmed-article:15477740pubmed:journalhttp://linkedlifedata.com/r...lld:pubmed
pubmed-article:15477740pubmed:citationSubsetIMlld:pubmed
pubmed-article:15477740pubmed:chemicalhttp://linkedlifedata.com/r...lld:pubmed
pubmed-article:15477740pubmed:chemicalhttp://linkedlifedata.com/r...lld:pubmed
pubmed-article:15477740pubmed:chemicalhttp://linkedlifedata.com/r...lld:pubmed
pubmed-article:15477740pubmed:statusMEDLINElld:pubmed
pubmed-article:15477740pubmed:monthAuglld:pubmed
pubmed-article:15477740pubmed:issn0957-4530lld:pubmed
pubmed-article:15477740pubmed:authorpubmed-author:TexierGGlld:pubmed
pubmed-article:15477740pubmed:authorpubmed-author:NagelM DMDlld:pubmed
pubmed-article:15477740pubmed:authorpubmed-author:DuvalJ LJLlld:pubmed
pubmed-article:15477740pubmed:authorpubmed-author:GloriantTTlld:pubmed
pubmed-article:15477740pubmed:authorpubmed-author:AnselDDlld:pubmed
pubmed-article:15477740pubmed:authorpubmed-author:GordinD MDMlld:pubmed
pubmed-article:15477740pubmed:authorpubmed-author:ThibonIIlld:pubmed
pubmed-article:15477740pubmed:issnTypePrintlld:pubmed
pubmed-article:15477740pubmed:volume15lld:pubmed
pubmed-article:15477740pubmed:ownerNLMlld:pubmed
pubmed-article:15477740pubmed:authorsCompleteYlld:pubmed
pubmed-article:15477740pubmed:pagination885-91lld:pubmed
pubmed-article:15477740pubmed:dateRevised2006-11-15lld:pubmed
pubmed-article:15477740pubmed:meshHeadingpubmed-meshheading:15477740...lld:pubmed
pubmed-article:15477740pubmed:meshHeadingpubmed-meshheading:15477740...lld:pubmed
pubmed-article:15477740pubmed:meshHeadingpubmed-meshheading:15477740...lld:pubmed
pubmed-article:15477740pubmed:meshHeadingpubmed-meshheading:15477740...lld:pubmed
pubmed-article:15477740pubmed:meshHeadingpubmed-meshheading:15477740...lld:pubmed
pubmed-article:15477740pubmed:meshHeadingpubmed-meshheading:15477740...lld:pubmed
pubmed-article:15477740pubmed:meshHeadingpubmed-meshheading:15477740...lld:pubmed
pubmed-article:15477740pubmed:meshHeadingpubmed-meshheading:15477740...lld:pubmed
pubmed-article:15477740pubmed:meshHeadingpubmed-meshheading:15477740...lld:pubmed
pubmed-article:15477740pubmed:meshHeadingpubmed-meshheading:15477740...lld:pubmed
pubmed-article:15477740pubmed:meshHeadingpubmed-meshheading:15477740...lld:pubmed
pubmed-article:15477740pubmed:meshHeadingpubmed-meshheading:15477740...lld:pubmed
pubmed-article:15477740pubmed:meshHeadingpubmed-meshheading:15477740...lld:pubmed
pubmed-article:15477740pubmed:meshHeadingpubmed-meshheading:15477740...lld:pubmed
pubmed-article:15477740pubmed:meshHeadingpubmed-meshheading:15477740...lld:pubmed
pubmed-article:15477740pubmed:meshHeadingpubmed-meshheading:15477740...lld:pubmed
pubmed-article:15477740pubmed:meshHeadingpubmed-meshheading:15477740...lld:pubmed
pubmed-article:15477740pubmed:year2004lld:pubmed
pubmed-article:15477740pubmed:articleTitleDevelopment of a beta-type Ti-12Mo-5Ta alloy for biomedical applications: cytocompatibility and metallurgical aspects.lld:pubmed
pubmed-article:15477740pubmed:affiliationInstitut National des Sciences Appliquées de Rennes, Groupe de Recherche en Chimie-Métallurgie, GRCM EA 2620, CS 14315, F-35043 Rennes, France.lld:pubmed
pubmed-article:15477740pubmed:publicationTypeJournal Articlelld:pubmed
pubmed-article:15477740pubmed:publicationTypeComparative Studylld:pubmed
pubmed-article:15477740pubmed:publicationTypeResearch Support, Non-U.S. Gov'tlld:pubmed
pubmed-article:15477740pubmed:publicationTypeEvaluation Studieslld:pubmed