Statements in which the resource exists.
SubjectPredicateObjectContext
pubmed-article:15354313rdf:typepubmed:Citationlld:pubmed
pubmed-article:15354313lifeskim:mentionsumls-concept:C0086418lld:lifeskim
pubmed-article:15354313lifeskim:mentionsumls-concept:C0025663lld:lifeskim
pubmed-article:15354313lifeskim:mentionsumls-concept:C0032105lld:lifeskim
pubmed-article:15354313lifeskim:mentionsumls-concept:C0302908lld:lifeskim
pubmed-article:15354313lifeskim:mentionsumls-concept:C0680730lld:lifeskim
pubmed-article:15354313lifeskim:mentionsumls-concept:C0185115lld:lifeskim
pubmed-article:15354313lifeskim:mentionsumls-concept:C0205554lld:lifeskim
pubmed-article:15354313lifeskim:mentionsumls-concept:C0037813lld:lifeskim
pubmed-article:15354313lifeskim:mentionsumls-concept:C0185125lld:lifeskim
pubmed-article:15354313lifeskim:mentionsumls-concept:C1519941lld:lifeskim
pubmed-article:15354313lifeskim:mentionsumls-concept:C1148554lld:lifeskim
pubmed-article:15354313lifeskim:mentionsumls-concept:C0392762lld:lifeskim
pubmed-article:15354313lifeskim:mentionsumls-concept:C1567174lld:lifeskim
pubmed-article:15354313pubmed:issue1lld:pubmed
pubmed-article:15354313pubmed:dateCreated2004-9-8lld:pubmed
pubmed-article:15354313pubmed:abstractTextSCH 201781 is a direct thrombin inhibitor recently under study in clinical trials to determine its safety and efficacy for the treatment of venous and arterial thrombosis. In aqueous solution, SCH 201781 exists as three forms, a ring-opened hydrated form and two ring-closed diastereomers. An automated solid-phase extraction LC-MS/MS method that chromatographically separates and measures each form was developed and validated from 1 to 1000 ng/mL in human plasma. For calibration curve standards, within- and between-run precision (%CV) ranged from 0.6 to 13.7%, while accuracy (%bias) ranged from -4.8 to 13.1%. For quality control samples, within- and between-run %CV ranged from 1.5 to 9.9% while %bias ranged from -9.1 to 4.9%. The method requires a sample volume of 0.8 ml and utilizes 2H6-labeled SCH 201781 as the internal standard. For sample processing, an Isolute C-8 96-well solid phase extraction plate and a Tomtec Quadra 96 sample processor is employed. Separation of the three forms of SCH 201781 is achieved using a 5 microm, 2 mm x 100 mm Asahipak C8 HPLC column and gradient elution. A Sciex API 365 equipped with a turbo ionspray source is used in the selected reaction monitoring mode for detection. The validated method was used to support clinical studies.lld:pubmed
pubmed-article:15354313pubmed:languageenglld:pubmed
pubmed-article:15354313pubmed:journalhttp://linkedlifedata.com/r...lld:pubmed
pubmed-article:15354313pubmed:citationSubsetIMlld:pubmed
pubmed-article:15354313pubmed:chemicalhttp://linkedlifedata.com/r...lld:pubmed
pubmed-article:15354313pubmed:chemicalhttp://linkedlifedata.com/r...lld:pubmed
pubmed-article:15354313pubmed:chemicalhttp://linkedlifedata.com/r...lld:pubmed
pubmed-article:15354313pubmed:statusMEDLINElld:pubmed
pubmed-article:15354313pubmed:monthSeplld:pubmed
pubmed-article:15354313pubmed:issn1570-0232lld:pubmed
pubmed-article:15354313pubmed:authorpubmed-author:WuNingNlld:pubmed
pubmed-article:15354313pubmed:authorpubmed-author:YangLiyuLlld:pubmed
pubmed-article:15354313pubmed:authorpubmed-author:RudewiczPatri...lld:pubmed
pubmed-article:15354313pubmed:authorpubmed-author:RuleGeoffrey...lld:pubmed
pubmed-article:15354313pubmed:authorpubmed-author:CampbellDale...lld:pubmed
pubmed-article:15354313pubmed:authorpubmed-author:PerkinsJohn...lld:pubmed
pubmed-article:15354313pubmed:issnTypePrintlld:pubmed
pubmed-article:15354313pubmed:day25lld:pubmed
pubmed-article:15354313pubmed:volume809lld:pubmed
pubmed-article:15354313pubmed:ownerNLMlld:pubmed
pubmed-article:15354313pubmed:authorsCompleteYlld:pubmed
pubmed-article:15354313pubmed:pagination75-80lld:pubmed
pubmed-article:15354313pubmed:dateRevised2006-11-15lld:pubmed
pubmed-article:15354313pubmed:meshHeadingpubmed-meshheading:15354313...lld:pubmed
pubmed-article:15354313pubmed:meshHeadingpubmed-meshheading:15354313...lld:pubmed
pubmed-article:15354313pubmed:meshHeadingpubmed-meshheading:15354313...lld:pubmed
pubmed-article:15354313pubmed:meshHeadingpubmed-meshheading:15354313...lld:pubmed
pubmed-article:15354313pubmed:meshHeadingpubmed-meshheading:15354313...lld:pubmed
pubmed-article:15354313pubmed:meshHeadingpubmed-meshheading:15354313...lld:pubmed
pubmed-article:15354313pubmed:meshHeadingpubmed-meshheading:15354313...lld:pubmed
pubmed-article:15354313pubmed:meshHeadingpubmed-meshheading:15354313...lld:pubmed
pubmed-article:15354313pubmed:meshHeadingpubmed-meshheading:15354313...lld:pubmed
pubmed-article:15354313pubmed:meshHeadingpubmed-meshheading:15354313...lld:pubmed
pubmed-article:15354313pubmed:meshHeadingpubmed-meshheading:15354313...lld:pubmed
pubmed-article:15354313pubmed:year2004lld:pubmed
pubmed-article:15354313pubmed:articleTitleValidation and application of an automated 96 -well solid-phase extraction liquid chromatography-tandem mass spectrometry method for the quantitative determination of SCH 201781 in human plasma.lld:pubmed
pubmed-article:15354313pubmed:affiliationSchering-Plough Research Institute, Kenilworth, NJ 07033-1300, USA.lld:pubmed
pubmed-article:15354313pubmed:publicationTypeJournal Articlelld:pubmed
pubmed-article:15354313pubmed:publicationTypeValidation Studieslld:pubmed