pubmed-article:15116951 | rdf:type | pubmed:Citation | lld:pubmed |
pubmed-article:15116951 | lifeskim:mentions | umls-concept:C0014834 | lld:lifeskim |
pubmed-article:15116951 | lifeskim:mentions | umls-concept:C1511790 | lld:lifeskim |
pubmed-article:15116951 | lifeskim:mentions | umls-concept:C0313106 | lld:lifeskim |
pubmed-article:15116951 | lifeskim:mentions | umls-concept:C0947659 | lld:lifeskim |
pubmed-article:15116951 | pubmed:issue | 4 | lld:pubmed |
pubmed-article:15116951 | pubmed:dateCreated | 2004-4-30 | lld:pubmed |
pubmed-article:15116951 | pubmed:abstractText | A silicon microcantilever sensor was developed for the detection of Escherichia coli O157:H7. The microcantilever was modified by anti-E. coli O157:H7 antibodies on the silicon surface of the cantilever. When the aquaria E. coli O157:H7 positive sample is injected into the fluid cell where the microcantilever is held, the microcantilever bends upon the recognition of the E. coli O157:H7 antigen by the antibodies on the surface of the microcantilever. A negative control sample that does not contain E. coli O157:H7 antigen did not cause any bending of the microcantilever. The detection limit of the sensor was 1 x 10(6) cfu/mL when the assay time was < 2 h. | lld:pubmed |
pubmed-article:15116951 | pubmed:language | eng | lld:pubmed |
pubmed-article:15116951 | pubmed:journal | http://linkedlifedata.com/r... | lld:pubmed |
pubmed-article:15116951 | pubmed:citationSubset | IM | lld:pubmed |
pubmed-article:15116951 | pubmed:chemical | http://linkedlifedata.com/r... | lld:pubmed |
pubmed-article:15116951 | pubmed:status | MEDLINE | lld:pubmed |
pubmed-article:15116951 | pubmed:month | Apr | lld:pubmed |
pubmed-article:15116951 | pubmed:issn | 0910-6340 | lld:pubmed |
pubmed-article:15116951 | pubmed:author | pubmed-author:ZhangJingJ | lld:pubmed |
pubmed-article:15116951 | pubmed:author | pubmed-author:JiHai-FengHF | lld:pubmed |
pubmed-article:15116951 | pubmed:issnType | Print | lld:pubmed |
pubmed-article:15116951 | pubmed:volume | 20 | lld:pubmed |
pubmed-article:15116951 | pubmed:owner | NLM | lld:pubmed |
pubmed-article:15116951 | pubmed:authorsComplete | Y | lld:pubmed |
pubmed-article:15116951 | pubmed:pagination | 585-7 | lld:pubmed |
pubmed-article:15116951 | pubmed:meshHeading | pubmed-meshheading:15116951... | lld:pubmed |
pubmed-article:15116951 | pubmed:meshHeading | pubmed-meshheading:15116951... | lld:pubmed |
pubmed-article:15116951 | pubmed:meshHeading | pubmed-meshheading:15116951... | lld:pubmed |
pubmed-article:15116951 | pubmed:meshHeading | pubmed-meshheading:15116951... | lld:pubmed |
pubmed-article:15116951 | pubmed:meshHeading | pubmed-meshheading:15116951... | lld:pubmed |
pubmed-article:15116951 | pubmed:year | 2004 | lld:pubmed |
pubmed-article:15116951 | pubmed:articleTitle | An anti E. coli O157:H7 antibody-immobilized microcantilever for the detection of Escherichia coli (E. coli). | lld:pubmed |
pubmed-article:15116951 | pubmed:affiliation | Department of Chemistry, Institute for Micromanufacturing, Louisiana Tech University, Ruston, Louisiana 71272, USA. | lld:pubmed |
pubmed-article:15116951 | pubmed:publicationType | Journal Article | lld:pubmed |
http://linkedlifedata.com/r... | pubmed:referesTo | pubmed-article:15116951 | lld:pubmed |