Statements in which the resource exists.
SubjectPredicateObjectContext
pubmed-article:15116951rdf:typepubmed:Citationlld:pubmed
pubmed-article:15116951lifeskim:mentionsumls-concept:C0014834lld:lifeskim
pubmed-article:15116951lifeskim:mentionsumls-concept:C1511790lld:lifeskim
pubmed-article:15116951lifeskim:mentionsumls-concept:C0313106lld:lifeskim
pubmed-article:15116951lifeskim:mentionsumls-concept:C0947659lld:lifeskim
pubmed-article:15116951pubmed:issue4lld:pubmed
pubmed-article:15116951pubmed:dateCreated2004-4-30lld:pubmed
pubmed-article:15116951pubmed:abstractTextA silicon microcantilever sensor was developed for the detection of Escherichia coli O157:H7. The microcantilever was modified by anti-E. coli O157:H7 antibodies on the silicon surface of the cantilever. When the aquaria E. coli O157:H7 positive sample is injected into the fluid cell where the microcantilever is held, the microcantilever bends upon the recognition of the E. coli O157:H7 antigen by the antibodies on the surface of the microcantilever. A negative control sample that does not contain E. coli O157:H7 antigen did not cause any bending of the microcantilever. The detection limit of the sensor was 1 x 10(6) cfu/mL when the assay time was < 2 h.lld:pubmed
pubmed-article:15116951pubmed:languageenglld:pubmed
pubmed-article:15116951pubmed:journalhttp://linkedlifedata.com/r...lld:pubmed
pubmed-article:15116951pubmed:citationSubsetIMlld:pubmed
pubmed-article:15116951pubmed:chemicalhttp://linkedlifedata.com/r...lld:pubmed
pubmed-article:15116951pubmed:statusMEDLINElld:pubmed
pubmed-article:15116951pubmed:monthAprlld:pubmed
pubmed-article:15116951pubmed:issn0910-6340lld:pubmed
pubmed-article:15116951pubmed:authorpubmed-author:ZhangJingJlld:pubmed
pubmed-article:15116951pubmed:authorpubmed-author:JiHai-FengHFlld:pubmed
pubmed-article:15116951pubmed:issnTypePrintlld:pubmed
pubmed-article:15116951pubmed:volume20lld:pubmed
pubmed-article:15116951pubmed:ownerNLMlld:pubmed
pubmed-article:15116951pubmed:authorsCompleteYlld:pubmed
pubmed-article:15116951pubmed:pagination585-7lld:pubmed
pubmed-article:15116951pubmed:meshHeadingpubmed-meshheading:15116951...lld:pubmed
pubmed-article:15116951pubmed:meshHeadingpubmed-meshheading:15116951...lld:pubmed
pubmed-article:15116951pubmed:meshHeadingpubmed-meshheading:15116951...lld:pubmed
pubmed-article:15116951pubmed:meshHeadingpubmed-meshheading:15116951...lld:pubmed
pubmed-article:15116951pubmed:meshHeadingpubmed-meshheading:15116951...lld:pubmed
pubmed-article:15116951pubmed:year2004lld:pubmed
pubmed-article:15116951pubmed:articleTitleAn anti E. coli O157:H7 antibody-immobilized microcantilever for the detection of Escherichia coli (E. coli).lld:pubmed
pubmed-article:15116951pubmed:affiliationDepartment of Chemistry, Institute for Micromanufacturing, Louisiana Tech University, Ruston, Louisiana 71272, USA.lld:pubmed
pubmed-article:15116951pubmed:publicationTypeJournal Articlelld:pubmed
http://linkedlifedata.com/r...pubmed:referesTopubmed-article:15116951lld:pubmed