pubmed-article:14608157 | rdf:type | pubmed:Citation | lld:pubmed |
pubmed-article:14608157 | lifeskim:mentions | umls-concept:C0030705 | lld:lifeskim |
pubmed-article:14608157 | lifeskim:mentions | umls-concept:C0043251 | lld:lifeskim |
pubmed-article:14608157 | lifeskim:mentions | umls-concept:C0205554 | lld:lifeskim |
pubmed-article:14608157 | lifeskim:mentions | umls-concept:C1979590 | lld:lifeskim |
pubmed-article:14608157 | lifeskim:mentions | umls-concept:C0443131 | lld:lifeskim |
pubmed-article:14608157 | pubmed:issue | 5 | lld:pubmed |
pubmed-article:14608157 | pubmed:dateCreated | 2003-11-10 | lld:pubmed |
pubmed-article:14608157 | pubmed:abstractText | Automated blood pressure (BP) determinations by oscillometry are reported to be as accurate as invasive monitoring for systolic pressures as low as 80 mm Hg. Automated BP devices are widely used by prehospital providers and in hospital operating rooms, emergency departments, and intensive care units, although the accuracy of automated BP has not been demonstrated in trauma patients. We hypothesized that automated BP is less accurate than manual BP in trauma patients. The purpose of this study was to determine the accuracy of automated BP versus manual BP in trauma patients. | lld:pubmed |
pubmed-article:14608157 | pubmed:language | eng | lld:pubmed |
pubmed-article:14608157 | pubmed:journal | http://linkedlifedata.com/r... | lld:pubmed |
pubmed-article:14608157 | pubmed:citationSubset | AIM | lld:pubmed |
pubmed-article:14608157 | pubmed:status | MEDLINE | lld:pubmed |
pubmed-article:14608157 | pubmed:month | Nov | lld:pubmed |
pubmed-article:14608157 | pubmed:issn | 0022-5282 | lld:pubmed |
pubmed-article:14608157 | pubmed:author | pubmed-author:DavisJames... | lld:pubmed |
pubmed-article:14608157 | pubmed:author | pubmed-author:KaupsKrista... | lld:pubmed |
pubmed-article:14608157 | pubmed:author | pubmed-author:ParksSteven... | lld:pubmed |
pubmed-article:14608157 | pubmed:author | pubmed-author:BenninkLynn... | lld:pubmed |
pubmed-article:14608157 | pubmed:author | pubmed-author:BilelloJohn... | lld:pubmed |
pubmed-article:14608157 | pubmed:author | pubmed-author:DavisIvan CIC | lld:pubmed |
pubmed-article:14608157 | pubmed:issnType | Print | lld:pubmed |
pubmed-article:14608157 | pubmed:volume | 55 | lld:pubmed |
pubmed-article:14608157 | pubmed:owner | NLM | lld:pubmed |
pubmed-article:14608157 | pubmed:authorsComplete | Y | lld:pubmed |
pubmed-article:14608157 | pubmed:pagination | 860-3 | lld:pubmed |
pubmed-article:14608157 | pubmed:dateRevised | 2004-11-17 | lld:pubmed |
pubmed-article:14608157 | pubmed:meshHeading | pubmed-meshheading:14608157... | lld:pubmed |
pubmed-article:14608157 | pubmed:meshHeading | pubmed-meshheading:14608157... | lld:pubmed |
pubmed-article:14608157 | pubmed:meshHeading | pubmed-meshheading:14608157... | lld:pubmed |
pubmed-article:14608157 | pubmed:meshHeading | pubmed-meshheading:14608157... | lld:pubmed |
pubmed-article:14608157 | pubmed:meshHeading | pubmed-meshheading:14608157... | lld:pubmed |
pubmed-article:14608157 | pubmed:meshHeading | pubmed-meshheading:14608157... | lld:pubmed |
pubmed-article:14608157 | pubmed:meshHeading | pubmed-meshheading:14608157... | lld:pubmed |
pubmed-article:14608157 | pubmed:meshHeading | pubmed-meshheading:14608157... | lld:pubmed |
pubmed-article:14608157 | pubmed:meshHeading | pubmed-meshheading:14608157... | lld:pubmed |
pubmed-article:14608157 | pubmed:meshHeading | pubmed-meshheading:14608157... | lld:pubmed |
pubmed-article:14608157 | pubmed:meshHeading | pubmed-meshheading:14608157... | lld:pubmed |
pubmed-article:14608157 | pubmed:meshHeading | pubmed-meshheading:14608157... | lld:pubmed |
pubmed-article:14608157 | pubmed:meshHeading | pubmed-meshheading:14608157... | lld:pubmed |
pubmed-article:14608157 | pubmed:year | 2003 | lld:pubmed |
pubmed-article:14608157 | pubmed:articleTitle | Are automated blood pressure measurements accurate in trauma patients? | lld:pubmed |
pubmed-article:14608157 | pubmed:affiliation | Department of Surgery, University Medical Center, University of California-San Francisco, 445 South Cedar Avenue, Fresno, CA 93702, USA. jdavis@ucsfresno.edu | lld:pubmed |
pubmed-article:14608157 | pubmed:publicationType | Journal Article | lld:pubmed |
http://linkedlifedata.com/r... | pubmed:referesTo | pubmed-article:14608157 | lld:pubmed |
http://linkedlifedata.com/r... | pubmed:referesTo | pubmed-article:14608157 | lld:pubmed |