pubmed-article:1432768 | rdf:type | pubmed:Citation | lld:pubmed |
pubmed-article:1432768 | lifeskim:mentions | umls-concept:C1314972 | lld:lifeskim |
pubmed-article:1432768 | lifeskim:mentions | umls-concept:C0024947 | lld:lifeskim |
pubmed-article:1432768 | lifeskim:mentions | umls-concept:C0205108 | lld:lifeskim |
pubmed-article:1432768 | lifeskim:mentions | umls-concept:C0237497 | lld:lifeskim |
pubmed-article:1432768 | lifeskim:mentions | umls-concept:C0231448 | lld:lifeskim |
pubmed-article:1432768 | lifeskim:mentions | umls-concept:C1707455 | lld:lifeskim |
pubmed-article:1432768 | lifeskim:mentions | umls-concept:C1705822 | lld:lifeskim |
pubmed-article:1432768 | lifeskim:mentions | umls-concept:C0348011 | lld:lifeskim |
pubmed-article:1432768 | lifeskim:mentions | umls-concept:C0185023 | lld:lifeskim |
pubmed-article:1432768 | lifeskim:mentions | umls-concept:C1947904 | lld:lifeskim |
pubmed-article:1432768 | lifeskim:mentions | umls-concept:C0011463 | lld:lifeskim |
pubmed-article:1432768 | lifeskim:mentions | umls-concept:C0183009 | lld:lifeskim |
pubmed-article:1432768 | lifeskim:mentions | umls-concept:C1705183 | lld:lifeskim |
pubmed-article:1432768 | lifeskim:mentions | umls-concept:C1709583 | lld:lifeskim |
pubmed-article:1432768 | lifeskim:mentions | umls-concept:C1999228 | lld:lifeskim |
pubmed-article:1432768 | lifeskim:mentions | umls-concept:C2825781 | lld:lifeskim |
pubmed-article:1432768 | lifeskim:mentions | umls-concept:C2346689 | lld:lifeskim |
pubmed-article:1432768 | lifeskim:mentions | umls-concept:C1550025 | lld:lifeskim |
pubmed-article:1432768 | pubmed:issue | 3 | lld:pubmed |
pubmed-article:1432768 | pubmed:dateCreated | 1992-12-23 | lld:pubmed |
pubmed-article:1432768 | pubmed:abstractText | This study photoelastically compared the stress distribution characteristics of two maxillary bilateral distal-extension removable partial denture designs, one using I-bar retention and the other using a semiprecision spring-loaded plunger attachment. Each prosthesis was subjected to vertical and horizontal extension-base loads. Comparisons were made from photographic recordings of isochromatic fringe distributions. The two retention designs produced comparable stresses with splinting of abutments for the plunger attachment. The attachment-retained prosthesis proved less stable with some loadings. Stress patterns followed three trajectories in the maxilla. A basis for stress distribution comparisons to other maxillary removable partial denture attachments is established. | lld:pubmed |
pubmed-article:1432768 | pubmed:grant | http://linkedlifedata.com/r... | lld:pubmed |
pubmed-article:1432768 | pubmed:language | eng | lld:pubmed |
pubmed-article:1432768 | pubmed:journal | http://linkedlifedata.com/r... | lld:pubmed |
pubmed-article:1432768 | pubmed:citationSubset | D | lld:pubmed |
pubmed-article:1432768 | pubmed:status | MEDLINE | lld:pubmed |
pubmed-article:1432768 | pubmed:month | Sep | lld:pubmed |
pubmed-article:1432768 | pubmed:issn | 0022-3913 | lld:pubmed |
pubmed-article:1432768 | pubmed:author | pubmed-author:BergTT | lld:pubmed |
pubmed-article:1432768 | pubmed:author | pubmed-author:CaputoA AAA | lld:pubmed |
pubmed-article:1432768 | pubmed:issnType | Print | lld:pubmed |
pubmed-article:1432768 | pubmed:volume | 68 | lld:pubmed |
pubmed-article:1432768 | pubmed:owner | NLM | lld:pubmed |
pubmed-article:1432768 | pubmed:authorsComplete | Y | lld:pubmed |
pubmed-article:1432768 | pubmed:pagination | 492-9 | lld:pubmed |
pubmed-article:1432768 | pubmed:dateRevised | 2007-11-14 | lld:pubmed |
pubmed-article:1432768 | pubmed:meshHeading | pubmed-meshheading:1432768-... | lld:pubmed |
pubmed-article:1432768 | pubmed:meshHeading | pubmed-meshheading:1432768-... | lld:pubmed |
pubmed-article:1432768 | pubmed:meshHeading | pubmed-meshheading:1432768-... | lld:pubmed |
pubmed-article:1432768 | pubmed:meshHeading | pubmed-meshheading:1432768-... | lld:pubmed |
pubmed-article:1432768 | pubmed:meshHeading | pubmed-meshheading:1432768-... | lld:pubmed |
pubmed-article:1432768 | pubmed:meshHeading | pubmed-meshheading:1432768-... | lld:pubmed |
pubmed-article:1432768 | pubmed:meshHeading | pubmed-meshheading:1432768-... | lld:pubmed |
pubmed-article:1432768 | pubmed:meshHeading | pubmed-meshheading:1432768-... | lld:pubmed |
pubmed-article:1432768 | pubmed:meshHeading | pubmed-meshheading:1432768-... | lld:pubmed |
pubmed-article:1432768 | pubmed:meshHeading | pubmed-meshheading:1432768-... | lld:pubmed |
pubmed-article:1432768 | pubmed:year | 1992 | lld:pubmed |
pubmed-article:1432768 | pubmed:articleTitle | Comparison of load transfer by maxillary distal extension removable partial dentures with a spring-loaded plunger attachment and I-bar retainer. | lld:pubmed |
pubmed-article:1432768 | pubmed:affiliation | University of California, School of Dentistry, Los Angeles. | lld:pubmed |
pubmed-article:1432768 | pubmed:publicationType | Journal Article | lld:pubmed |
pubmed-article:1432768 | pubmed:publicationType | Comparative Study | lld:pubmed |
pubmed-article:1432768 | pubmed:publicationType | Research Support, U.S. Gov't, P.H.S. | lld:pubmed |
pubmed-article:1432768 | pubmed:publicationType | Research Support, Non-U.S. Gov't | lld:pubmed |