Statements in which the resource exists.
SubjectPredicateObjectContext
pubmed-article:12871802rdf:typepubmed:Citationlld:pubmed
pubmed-article:12871802lifeskim:mentionsumls-concept:C0040975lld:lifeskim
pubmed-article:12871802lifeskim:mentionsumls-concept:C1546637lld:lifeskim
pubmed-article:12871802lifeskim:mentionsumls-concept:C1704449lld:lifeskim
pubmed-article:12871802lifeskim:mentionsumls-concept:C1704684lld:lifeskim
pubmed-article:12871802lifeskim:mentionsumls-concept:C1540034lld:lifeskim
pubmed-article:12871802lifeskim:mentionsumls-concept:C1442080lld:lifeskim
pubmed-article:12871802lifeskim:mentionsumls-concept:C0262880lld:lifeskim
pubmed-article:12871802lifeskim:mentionsumls-concept:C0678118lld:lifeskim
pubmed-article:12871802lifeskim:mentionsumls-concept:C0180860lld:lifeskim
pubmed-article:12871802lifeskim:mentionsumls-concept:C0581406lld:lifeskim
pubmed-article:12871802lifeskim:mentionsumls-concept:C0183395lld:lifeskim
pubmed-article:12871802lifeskim:mentionsumls-concept:C1522664lld:lifeskim
pubmed-article:12871802lifeskim:mentionsumls-concept:C0205195lld:lifeskim
pubmed-article:12871802lifeskim:mentionsumls-concept:C1710143lld:lifeskim
pubmed-article:12871802lifeskim:mentionsumls-concept:C1550638lld:lifeskim
pubmed-article:12871802lifeskim:mentionsumls-concept:C0276640lld:lifeskim
pubmed-article:12871802pubmed:issue3-4lld:pubmed
pubmed-article:12871802pubmed:dateCreated2003-7-21lld:pubmed
pubmed-article:12871802pubmed:abstractTextA high-energy resolution post-column spectrometer for the purpose of electron energy loss spectroscopy (EELS) and energy-filtered TEM in combination with a monochromated (S)TEM is presented. The prism aberrations were corrected up to fourth order using multipole elements improving the electron optical energy resolution and increasing the acceptance of the spectrometer for a combination of object area and collection angles. Electronics supplying the prism, drift tube, high-tension reference and critical lenses have been newly designed such that, in combination with the new electron optics, a sub-50 meV energy resolution has been realized, a 10-fold improvement over past post-column spectrometer designs. The first system has been installed on a 200 kV monochromated TEM at the Delft University of Technology. Total system energy resolution of sub-100 meV has been demonstrated. For a 1s exposure the resolution degraded to 110 meV as a result of noise. No further degradation in energy resolution was measured for exposures up to 1 min at 120 kV. Spectral resolution measurements, performed on the pi* peak of the BN K-edge, demonstrated a 350 meV (FWHM) peak width at 200 kV. This measure is predominantly determined by the natural line width of the BN K-edge.lld:pubmed
pubmed-article:12871802pubmed:languageenglld:pubmed
pubmed-article:12871802pubmed:journalhttp://linkedlifedata.com/r...lld:pubmed
pubmed-article:12871802pubmed:statusPubMed-not-MEDLINElld:pubmed
pubmed-article:12871802pubmed:monthSeplld:pubmed
pubmed-article:12871802pubmed:issn0304-3991lld:pubmed
pubmed-article:12871802pubmed:authorpubmed-author:BrandP HPHlld:pubmed
pubmed-article:12871802pubmed:authorpubmed-author:EdwardsB NBNlld:pubmed
pubmed-article:12871802pubmed:authorpubmed-author:BarfelsM M...lld:pubmed
pubmed-article:12871802pubmed:authorpubmed-author:BurgnerR PRPlld:pubmed
pubmed-article:12871802pubmed:issnTypePrintlld:pubmed
pubmed-article:12871802pubmed:volume96lld:pubmed
pubmed-article:12871802pubmed:ownerNLMlld:pubmed
pubmed-article:12871802pubmed:authorsCompleteYlld:pubmed
pubmed-article:12871802pubmed:pagination367-84lld:pubmed
pubmed-article:12871802pubmed:year2003lld:pubmed
pubmed-article:12871802pubmed:articleTitleA sub-50meV spectrometer and energy filter for use in combination with 200kV monochromated (S)TEMs.lld:pubmed
pubmed-article:12871802pubmed:affiliationGatan Research and Development, 5933 Coronado Lane, Pleasanton, CA 94588, USA.lld:pubmed
pubmed-article:12871802pubmed:publicationTypeJournal Articlelld:pubmed
http://linkedlifedata.com/r...pubmed:referesTopubmed-article:12871802lld:pubmed
http://linkedlifedata.com/r...pubmed:referesTopubmed-article:12871802lld:pubmed