Statements in which the resource exists.
SubjectPredicateObjectContext
pubmed-article:12111126rdf:typepubmed:Citationlld:pubmed
pubmed-article:12111126lifeskim:mentionsumls-concept:C0024109lld:lifeskim
pubmed-article:12111126lifeskim:mentionsumls-concept:C0025663lld:lifeskim
pubmed-article:12111126lifeskim:mentionsumls-concept:C0031001lld:lifeskim
pubmed-article:12111126lifeskim:mentionsumls-concept:C0035203lld:lifeskim
pubmed-article:12111126lifeskim:mentionsumls-concept:C0042491lld:lifeskim
pubmed-article:12111126lifeskim:mentionsumls-concept:C0392762lld:lifeskim
pubmed-article:12111126lifeskim:mentionsumls-concept:C0679622lld:lifeskim
pubmed-article:12111126lifeskim:mentionsumls-concept:C0205314lld:lifeskim
pubmed-article:12111126lifeskim:mentionsumls-concept:C0521115lld:lifeskim
pubmed-article:12111126pubmed:issue7lld:pubmed
pubmed-article:12111126pubmed:dateCreated2002-7-11lld:pubmed
pubmed-article:12111126pubmed:abstractTextA quantitative dual-isotope single-photon emission tomography (SPET) technique for the assessment of lung ventilation (V) and perfusion (Q) using, respectively, technetium-99m labelled Technegas (140 keV) and indium-113m labelled macro-aggregated albumin (392 keV), is presented, validated and clinically tested in a healthy volunteer. In order to assess V, Q and V/Q distributions in quantitative terms, algorithms which correct for down scattering, photon scattering and attenuation, as well as an organ outline algorithm, were implemented. Scatter and down-scatter correction were made in the spatial domain by pixel-wise image subtraction of projection-dependent global scattering factors obtained from the energy domain. The attenuation correction was based on an iterative projection/back-projection method. All studies were made on a three-headed SPET system (Trionix) with medium-energy parallel-hole collimators. The set of input data for quantification was based on SPET acquisition of emission data in four separate energy windows, the associated cumulative energy spectra and transmission data. The attenuation correction routine as well as the edge detection algorithm utilized data from (99m)Tc transmission tomography. Attenuation data for (113m)In were obtained by linear scaling of the (99m)Tc attenuation maps. The correction algorithms were experimentally validated with a stack phantom system and applied on a healthy volunteer. The mean difference between the corrected SPET data of the dense stack lung phantom and those obtained from the corresponding scatter- and attenuation-"free" version was only 1.9% for (99m)Tc and 0.9% for (113m)In. The estimated fractional V/Q distribution in the 3-D lung phantom volume had its peak at V/Q=1, with a width (FWHM) of 0.31 due to noise, particularly in the (113m)In images, and to partial volume effects. For a healthy volunteer, the corresponding values were 0.9 and 0.35, respectively. This method allows accurate assessment of radionuclide distribution on a regional basis. For basic lung physiology and clinical practice, the method allows assessment of the global frequency functions of the V, Q and V/Q distributions.lld:pubmed
pubmed-article:12111126pubmed:languageenglld:pubmed
pubmed-article:12111126pubmed:journalhttp://linkedlifedata.com/r...lld:pubmed
pubmed-article:12111126pubmed:citationSubsetIMlld:pubmed
pubmed-article:12111126pubmed:chemicalhttp://linkedlifedata.com/r...lld:pubmed
pubmed-article:12111126pubmed:chemicalhttp://linkedlifedata.com/r...lld:pubmed
pubmed-article:12111126pubmed:chemicalhttp://linkedlifedata.com/r...lld:pubmed
pubmed-article:12111126pubmed:chemicalhttp://linkedlifedata.com/r...lld:pubmed
pubmed-article:12111126pubmed:statusMEDLINElld:pubmed
pubmed-article:12111126pubmed:monthJullld:pubmed
pubmed-article:12111126pubmed:issn1619-7070lld:pubmed
pubmed-article:12111126pubmed:authorpubmed-author:GlennyRobb...lld:pubmed
pubmed-article:12111126pubmed:authorpubmed-author:JacobssonHans...lld:pubmed
pubmed-article:12111126pubmed:authorpubmed-author:LarssonStig...lld:pubmed
pubmed-article:12111126pubmed:authorpubmed-author:LindahlSten...lld:pubmed
pubmed-article:12111126pubmed:authorpubmed-author:Sánchez-Cresp...lld:pubmed
pubmed-article:12111126pubmed:authorpubmed-author:PeterssonJoha...lld:pubmed
pubmed-article:12111126pubmed:authorpubmed-author:NyrenSvenSlld:pubmed
pubmed-article:12111126pubmed:authorpubmed-author:MureMargareta...lld:pubmed
pubmed-article:12111126pubmed:authorpubmed-author:ThorellJan-Ol...lld:pubmed
pubmed-article:12111126pubmed:issnTypePrintlld:pubmed
pubmed-article:12111126pubmed:volume29lld:pubmed
pubmed-article:12111126pubmed:ownerNLMlld:pubmed
pubmed-article:12111126pubmed:authorsCompleteYlld:pubmed
pubmed-article:12111126pubmed:pagination863-75lld:pubmed
pubmed-article:12111126pubmed:dateRevised2006-11-15lld:pubmed
pubmed-article:12111126pubmed:meshHeadingpubmed-meshheading:12111126...lld:pubmed
pubmed-article:12111126pubmed:meshHeadingpubmed-meshheading:12111126...lld:pubmed
pubmed-article:12111126pubmed:meshHeadingpubmed-meshheading:12111126...lld:pubmed
pubmed-article:12111126pubmed:meshHeadingpubmed-meshheading:12111126...lld:pubmed
pubmed-article:12111126pubmed:meshHeadingpubmed-meshheading:12111126...lld:pubmed
pubmed-article:12111126pubmed:meshHeadingpubmed-meshheading:12111126...lld:pubmed
pubmed-article:12111126pubmed:meshHeadingpubmed-meshheading:12111126...lld:pubmed
pubmed-article:12111126pubmed:meshHeadingpubmed-meshheading:12111126...lld:pubmed
pubmed-article:12111126pubmed:meshHeadingpubmed-meshheading:12111126...lld:pubmed
pubmed-article:12111126pubmed:meshHeadingpubmed-meshheading:12111126...lld:pubmed
pubmed-article:12111126pubmed:meshHeadingpubmed-meshheading:12111126...lld:pubmed
pubmed-article:12111126pubmed:meshHeadingpubmed-meshheading:12111126...lld:pubmed
pubmed-article:12111126pubmed:meshHeadingpubmed-meshheading:12111126...lld:pubmed
pubmed-article:12111126pubmed:year2002lld:pubmed
pubmed-article:12111126pubmed:articleTitleA novel quantitative dual-isotope method for simultaneous ventilation and perfusion lung SPET.lld:pubmed
pubmed-article:12111126pubmed:affiliationMedical Radiation Physics, Department of Oncology-Pathology, Stockholm University and Karolinska Institute, Sweden. alejandro.sanchez-crespo@ks.selld:pubmed
pubmed-article:12111126pubmed:publicationTypeJournal Articlelld:pubmed
pubmed-article:12111126pubmed:publicationTypeResearch Support, Non-U.S. Gov'tlld:pubmed
pubmed-article:12111126pubmed:publicationTypeValidation Studieslld:pubmed