Statements in which the resource exists.
SubjectPredicateObjectContext
pubmed-article:10896198rdf:typepubmed:Citationlld:pubmed
pubmed-article:10896198lifeskim:mentionsumls-concept:C0034372lld:lifeskim
pubmed-article:10896198lifeskim:mentionsumls-concept:C0025663lld:lifeskim
pubmed-article:10896198lifeskim:mentionsumls-concept:C0018563lld:lifeskim
pubmed-article:10896198lifeskim:mentionsumls-concept:C0238767lld:lifeskim
pubmed-article:10896198lifeskim:mentionsumls-concept:C0220843lld:lifeskim
pubmed-article:10896198lifeskim:mentionsumls-concept:C1948023lld:lifeskim
pubmed-article:10896198lifeskim:mentionsumls-concept:C2587213lld:lifeskim
pubmed-article:10896198lifeskim:mentionsumls-concept:C0034384lld:lifeskim
pubmed-article:10896198lifeskim:mentionsumls-concept:C1547564lld:lifeskim
pubmed-article:10896198pubmed:issue2lld:pubmed
pubmed-article:10896198pubmed:dateCreated2000-12-5lld:pubmed
pubmed-article:10896198pubmed:abstractTextElectrical stimulation has been applied to the paralyzed muscles of both hands of two persons with tetraplegia using percutaneous and implantable electrodes. Two separate methods of user control were being investigated. The first monitored the myoelectric signals from the user's own sternocleidomastoid muscles and the second monitored wrist joint angle. These signals were used as commands to modify the stimulated grasps. The hands were instrumented to detect the degree of hand closure and grip force and the users matched these to specific target parameters using the controller during tracking tasks. Performance in these tracking tasks was measured quantitatively. Wrist control was found to be less sensitive to the direction of hand opening/closing required than the myoelectric control. The user's performance with the myoelectric control demonstrated sensitivity to the target size and the speed of hand movement in response to the command control. The wrist controller required less training than the myoelectric controller for users to become proficient in its use. Based on these results, the wrist controller and the myoelectric controller both provide successful control of bilateral hand grasp and release. Of the two controllers, the wrist controller is likely to provide the greater ease of use, although it is only available to the population of users with active wrist extension.lld:pubmed
pubmed-article:10896198pubmed:languageenglld:pubmed
pubmed-article:10896198pubmed:journalhttp://linkedlifedata.com/r...lld:pubmed
pubmed-article:10896198pubmed:citationSubsetIMlld:pubmed
pubmed-article:10896198pubmed:statusMEDLINElld:pubmed
pubmed-article:10896198pubmed:monthJunlld:pubmed
pubmed-article:10896198pubmed:issn1063-6528lld:pubmed
pubmed-article:10896198pubmed:authorpubmed-author:ScottT RTRlld:pubmed
pubmed-article:10896198pubmed:authorpubmed-author:GschwindC RCRlld:pubmed
pubmed-article:10896198pubmed:authorpubmed-author:MiddletonJ...lld:pubmed
pubmed-article:10896198pubmed:authorpubmed-author:RutkowskiS...lld:pubmed
pubmed-article:10896198pubmed:authorpubmed-author:HeasmanJ MJMlld:pubmed
pubmed-article:10896198pubmed:authorpubmed-author:VareV AVAlld:pubmed
pubmed-article:10896198pubmed:authorpubmed-author:FlynnR YRYlld:pubmed
pubmed-article:10896198pubmed:issnTypePrintlld:pubmed
pubmed-article:10896198pubmed:volume8lld:pubmed
pubmed-article:10896198pubmed:ownerNLMlld:pubmed
pubmed-article:10896198pubmed:authorsCompleteYlld:pubmed
pubmed-article:10896198pubmed:pagination259-67lld:pubmed
pubmed-article:10896198pubmed:dateRevised2006-11-15lld:pubmed
pubmed-article:10896198pubmed:meshHeadingpubmed-meshheading:10896198...lld:pubmed
pubmed-article:10896198pubmed:meshHeadingpubmed-meshheading:10896198...lld:pubmed
pubmed-article:10896198pubmed:meshHeadingpubmed-meshheading:10896198...lld:pubmed
pubmed-article:10896198pubmed:meshHeadingpubmed-meshheading:10896198...lld:pubmed
pubmed-article:10896198pubmed:meshHeadingpubmed-meshheading:10896198...lld:pubmed
pubmed-article:10896198pubmed:meshHeadingpubmed-meshheading:10896198...lld:pubmed
pubmed-article:10896198pubmed:meshHeadingpubmed-meshheading:10896198...lld:pubmed
pubmed-article:10896198pubmed:meshHeadingpubmed-meshheading:10896198...lld:pubmed
pubmed-article:10896198pubmed:meshHeadingpubmed-meshheading:10896198...lld:pubmed
pubmed-article:10896198pubmed:year2000lld:pubmed
pubmed-article:10896198pubmed:articleTitleQuantitative evaluation of two methods of control of bilateral stimulated hand grasps in persons with tetraplegia.lld:pubmed
pubmed-article:10896198pubmed:affiliationDepartment of Hand and Microsurgery, Biomedical Engineering for the Northern Sydney Health, Royal North Shore Hospital, St Leonards, NSW, Australia.lld:pubmed
pubmed-article:10896198pubmed:publicationTypeJournal Articlelld:pubmed
pubmed-article:10896198pubmed:publicationTypeResearch Support, Non-U.S. Gov'tlld:pubmed