Statements in which the resource exists.
SubjectPredicateObjectContext
pubmed-article:10369795rdf:typepubmed:Citationlld:pubmed
pubmed-article:10369795lifeskim:mentionsumls-concept:C0205101lld:lifeskim
pubmed-article:10369795lifeskim:mentionsumls-concept:C0302148lld:lifeskim
pubmed-article:10369795lifeskim:mentionsumls-concept:C1280500lld:lifeskim
pubmed-article:10369795lifeskim:mentionsumls-concept:C0205234lld:lifeskim
pubmed-article:10369795lifeskim:mentionsumls-concept:C1442080lld:lifeskim
pubmed-article:10369795lifeskim:mentionsumls-concept:C0001166lld:lifeskim
pubmed-article:10369795lifeskim:mentionsumls-concept:C1533691lld:lifeskim
pubmed-article:10369795lifeskim:mentionsumls-concept:C0185125lld:lifeskim
pubmed-article:10369795lifeskim:mentionsumls-concept:C0332453lld:lifeskim
pubmed-article:10369795pubmed:issue1lld:pubmed
pubmed-article:10369795pubmed:dateCreated1999-12-21lld:pubmed
pubmed-article:10369795pubmed:abstractTextApplication of low-frequency ultrasound for clot disruption has been suggested as a potential therapy to enhance thrombus dissolution, but the optimal mode for delivery of ultrasound with clot-disruptive properties has not yet been extensively explored. Target-specific effects are desirable and may be accomplished by focusing the ultrasound. Adequate focusing, however, requires a short wavelength. The aim of this study was to compare the clot-disruptive effects of different modalities of focused acoustic energy. An in vitro model (10 blood clots for each modality) was used to test the clot-disruptive capacity of (i) shock waves generated in an electrohydraulic lithotriptor; (ii) focused continuous ultrasound of frequency 1.1 MHz, delivered from a specially constructed piezoelectric transducer; and (iii) focused pulse-modulated ultrasound of frequency 1.1 MHz delivered from the same transducer. Exposure to 30 s of focused pulse-modulated ultrasound caused a marked reduction (99+/-2%) in clot weight compared with 30 shock waves (11+/-5%) or 30 s exposure to focused continuous wave ultrasound (11+/-6%) (P<0.0001). The observed marked and rapid disruptive effect on blood clots of focused high-frequency ultrasound indicates an alternative approach for external ultrasound-mediated thrombus destruction in vivo. The focused pulse-modulated technique has potential to exhibit the desired effect in a well-defined target volume and provides the means for control of the average power.lld:pubmed
pubmed-article:10369795pubmed:languageenglld:pubmed
pubmed-article:10369795pubmed:journalhttp://linkedlifedata.com/r...lld:pubmed
pubmed-article:10369795pubmed:citationSubsetIMlld:pubmed
pubmed-article:10369795pubmed:statusMEDLINElld:pubmed
pubmed-article:10369795pubmed:monthJullld:pubmed
pubmed-article:10369795pubmed:issn0143-5221lld:pubmed
pubmed-article:10369795pubmed:authorpubmed-author:ElmqvistHHlld:pubmed
pubmed-article:10369795pubmed:authorpubmed-author:BerglundHHlld:pubmed
pubmed-article:10369795pubmed:authorpubmed-author:HultenbyKKlld:pubmed
pubmed-article:10369795pubmed:authorpubmed-author:WiksellHHlld:pubmed
pubmed-article:10369795pubmed:authorpubmed-author:WestermarkSSlld:pubmed
pubmed-article:10369795pubmed:issnTypePrintlld:pubmed
pubmed-article:10369795pubmed:volume97lld:pubmed
pubmed-article:10369795pubmed:ownerNLMlld:pubmed
pubmed-article:10369795pubmed:authorsCompleteYlld:pubmed
pubmed-article:10369795pubmed:pagination67-71lld:pubmed
pubmed-article:10369795pubmed:dateRevised2006-11-15lld:pubmed
pubmed-article:10369795pubmed:meshHeadingpubmed-meshheading:10369795...lld:pubmed
pubmed-article:10369795pubmed:meshHeadingpubmed-meshheading:10369795...lld:pubmed
pubmed-article:10369795pubmed:meshHeadingpubmed-meshheading:10369795...lld:pubmed
pubmed-article:10369795pubmed:meshHeadingpubmed-meshheading:10369795...lld:pubmed
pubmed-article:10369795pubmed:year1999lld:pubmed
pubmed-article:10369795pubmed:articleTitleEffect of externally applied focused acoustic energy on clot disruption in vitro.lld:pubmed
pubmed-article:10369795pubmed:affiliationDepartment of Medical Laboratory Science and Technology, Karolinska Institute, Huddinge University Hospital, 141 86 Huddinge, Stockholm, Sweden.lld:pubmed
pubmed-article:10369795pubmed:publicationTypeJournal Articlelld:pubmed
pubmed-article:10369795pubmed:publicationTypeResearch Support, Non-U.S. Gov'tlld:pubmed