Statements in which the resource exists.
SubjectPredicateObjectContext
pubmed-article:10155074rdf:typepubmed:Citationlld:pubmed
pubmed-article:10155074lifeskim:mentionsumls-concept:C0190211lld:lifeskim
pubmed-article:10155074lifeskim:mentionsumls-concept:C0022116lld:lifeskim
pubmed-article:10155074lifeskim:mentionsumls-concept:C0439793lld:lifeskim
pubmed-article:10155074lifeskim:mentionsumls-concept:C0442967lld:lifeskim
pubmed-article:10155074lifeskim:mentionsumls-concept:C2828008lld:lifeskim
pubmed-article:10155074lifeskim:mentionsumls-concept:C0392762lld:lifeskim
pubmed-article:10155074lifeskim:mentionsumls-concept:C0549193lld:lifeskim
pubmed-article:10155074lifeskim:mentionsumls-concept:C0439792lld:lifeskim
pubmed-article:10155074lifeskim:mentionsumls-concept:C0439608lld:lifeskim
pubmed-article:10155074pubmed:issue7lld:pubmed
pubmed-article:10155074pubmed:dateCreated1995-11-13lld:pubmed
pubmed-article:10155074pubmed:abstractTextLong angioplasty inflations have been reported using an autoperfusion system that delivers oxygenated blood distal to the balloon segment. The safety and efficacy of this system has been demonstrated in anatomically selected patients. The clinical use, however, is frequently to stabilize intimal dissection in unselected patients. We reviewed 12-lead continuous electrocardiographic (ECG) recordings in 40 patients in whom prolonged salvage with autoperfusion was attempted. Sub-optimal results were stabilized in 36 of 40, while 4 patients had urgent bypass. The presence of ischemia, as > or = 100 uV ST elevation over the 12 lead ECG, and the total ST deviation over all leads over the entire inflation period (total ischemic "burden") were compared within each patient between the longest standard balloon and autoperfusion inflations. Median duration of inflation was 3.03 min. with balloon vs. 15.6 min. with autoperfusion (p < 0.00002). Of the 40 patients, 35 (87%) had ECG ischemia with balloon vs. 18 (45%) with autoperfusion (p < .00002). Median severity of peak ST deviation was 321 uV with balloon vs. 132 uV with autoperfusion (p = 0.0001). Median extent of ST elevation was 3 leads with balloon vs. 0 leads with autoperfusion (p = 0.0001). Median total ischemic burden was similar with balloon (1173 uVmin) and autoperfusion (1083 uVmin, NS) despite the fivefold longer inflation duration with autoperfusion. Thus, in patients selected by clinical necessity rather than optimal anatomy, severity and extent of ST elevation were significantly reduced, although not entirely eliminated, by autoperfusion.lld:pubmed
pubmed-article:10155074pubmed:languageenglld:pubmed
pubmed-article:10155074pubmed:journalhttp://linkedlifedata.com/r...lld:pubmed
pubmed-article:10155074pubmed:citationSubsetTlld:pubmed
pubmed-article:10155074pubmed:statusMEDLINElld:pubmed
pubmed-article:10155074pubmed:monthSeplld:pubmed
pubmed-article:10155074pubmed:issn1042-3931lld:pubmed
pubmed-article:10155074pubmed:authorpubmed-author:PhillipsH RHRlld:pubmed
pubmed-article:10155074pubmed:authorpubmed-author:PopeJ EJElld:pubmed
pubmed-article:10155074pubmed:authorpubmed-author:KrucoffM WMWlld:pubmed
pubmed-article:10155074pubmed:authorpubmed-author:BengtsonJ RJRlld:pubmed
pubmed-article:10155074pubmed:authorpubmed-author:VeldkampR FRFlld:pubmed
pubmed-article:10155074pubmed:authorpubmed-author:WildermannN...lld:pubmed
pubmed-article:10155074pubmed:authorpubmed-author:SketchM HMHJrlld:pubmed
pubmed-article:10155074pubmed:authorpubmed-author:CraterSSlld:pubmed
pubmed-article:10155074pubmed:authorpubmed-author:KananiP MPMlld:pubmed
pubmed-article:10155074pubmed:authorpubmed-author:SawchakS RSRlld:pubmed
pubmed-article:10155074pubmed:issnTypePrintlld:pubmed
pubmed-article:10155074pubmed:volume6lld:pubmed
pubmed-article:10155074pubmed:ownerNLMlld:pubmed
pubmed-article:10155074pubmed:authorsCompleteYlld:pubmed
pubmed-article:10155074pubmed:pagination234-40lld:pubmed
pubmed-article:10155074pubmed:dateRevised2010-11-18lld:pubmed
pubmed-article:10155074pubmed:meshHeadingpubmed-meshheading:10155074...lld:pubmed
pubmed-article:10155074pubmed:meshHeadingpubmed-meshheading:10155074...lld:pubmed
pubmed-article:10155074pubmed:meshHeadingpubmed-meshheading:10155074...lld:pubmed
pubmed-article:10155074pubmed:meshHeadingpubmed-meshheading:10155074...lld:pubmed
pubmed-article:10155074pubmed:meshHeadingpubmed-meshheading:10155074...lld:pubmed
pubmed-article:10155074pubmed:meshHeadingpubmed-meshheading:10155074...lld:pubmed
pubmed-article:10155074pubmed:meshHeadingpubmed-meshheading:10155074...lld:pubmed
pubmed-article:10155074pubmed:meshHeadingpubmed-meshheading:10155074...lld:pubmed
pubmed-article:10155074pubmed:year1994lld:pubmed
pubmed-article:10155074pubmed:articleTitleThe impact of autoperfusion on quantitative electrocardiographic parameters of ischemia severity, extent, and "burden" during salvage of elective coronary angioplasty.lld:pubmed
pubmed-article:10155074pubmed:affiliationDepartment of Medicine, Duke University Medical Center, Durham, North Carolina 27710, USA.lld:pubmed
pubmed-article:10155074pubmed:publicationTypeJournal Articlelld:pubmed